Using high-speed ADC data collection, resolution up to 1μm, can simultaneously measure the thickness of multi-layer coatings or coatings plus substrates, with gain automatic switching and estimated thickness setting function, Measurement range 13~ 1000μm (epoxy resin coating).
Using the magnetic induction method, the measurement range is 0~2000 μm, with an error of ±5%, a resolution of 0.1 μm. It supports separate probes and low-voltage alerts, and is suitable for various types of coatings.
Using ultrasonic technology implementation nondestructive measurement, Measurement range 50~ 7600 μ m, accuracy +/- 3%, with weatherproof design and support for multi-coating system analysis, built-in statistical functions and a variety of Interface.
Measurement of thick soft coatings such as polyurea and asphalt, thickness range 50 to 7600 μm, storage of 100,000 readings, ASTM D6132 compliant, non-destructive ultrasonic technology, durable and easy to operate.
Measurement range of 50~ 7600 μm, error +/- 3%, suitable for thick soft coatings such as polyurea and asphalt neoprene, providing accurate thickness detection.
Using ultrasonic technology implementation nondestructive measurement, Measurement range 50~ 3800μm, accuracy +/- 3%, with weatherproof design, support USB data transmission and a variety of Unit switching, suitable for a variety of substrate conditions.
Measurement principle using ultrasonic, Measurement range 13~ 1000μm, accuracy +/- (2μm + 3%), suitable for wood, plastic and other substrates polymer Coating thickness detection.
Using ultrasonic technology implementation nondestructive measurement, Measurement range 13~ 1000μm, accuracy +/- 3%, support multi-coating system analysis, with weatherproof protection and a variety of data transmission methods.
Measurement range 0-1000 microns with dual-function Probe design, wear-resistant Ruby Probe and V-groove structure, support for automatic substrate identification and zero point Adjustment.
High-speed ADC data collection to achieve 1 μm resolution, with multi-layer coatings simultaneous measurement function, measurement range covering 13~ 1000 μm (epoxy resin) and 300~ 14800 μm (45 #steel), support waveform display and automatic gain switching.
Using ultrasonic technology nondestructive measurement, up to 3 layers of coating system measurement range 50~ 3800 μ m, error +/- 3%, with weatherproof design and high capacity Data storage function.
Using wooden handle material and high-quality alloy steel blades, the tooth spacing is 2mm, the number of teeth is 6, the top width of the blade is less than 0.05mm, the included angle is 30 ° +/- 1 °, suitable for film Film thickness 61μm~ 120μm hard substrate or Film thickness < 120μm soft substrate, ergonomic design is labor-saving, and the blade can be easily replaced.
Measurement thickness up to 63.5 mm, accuracy of +/- 3%, measurement of magnetic and nonmagnetic metal substrates on nonconductive coatings, equipped with braided stainless steel cable anti-torsion wear.
Measurement principle using ultrasonic, Measurement range 50~ 3800μm, accuracy +/- (2μm + 3%), suitable for concrete and fiberglass substrate Coating thickness detection.
The impact height is adjustable from 0 to 100 cm, with optional impactor weights of 1000 g or 2 lbs. It is equipped with a depth control ring and a mold base, supporting ISO 6272 and ASTM D2794 standard tests.