Adopt electromagnetic force closed-loop measurement system, Measurement range 0-400mN/m, resolution +/- 0.1mN/m, automatically read equilibrate value, support high viscosity liquid and interfacial tension test, simple operation without external computer control.
Adopt electromagnetic force closed-loop measurement system, accuracy +/- 0.02mN/m, support 0-200mN/m range measurement, with automatic lifting and temperature detection functions, can test high viscosity liquids and dynamic surface tension changes.
The manual lifting platform is equipped with fast fine-tuning dual gear, supports platinum plate method and ring method dual Measurement mode, Measurement range 0-400mN/m, error is only +/- 0.1mN/m, can be connected to the computer to display the tension change in real time Linear dispersion.
Measurement range 0~ 200mN/m, standard error +/- 0.03mN/m, support real-time Linear dispersion display and thermostatic control, easy and reliable operation.
With a fully automatic liquid inlet device, the liquid inlet accuracy reaches 0.001 μL, equipped with SONY high-speed industrial-grade chip and a variety of Measuring methods, it can accurately measure 0-180 ° contact angle and 0-3000mN/m surface tension to meet various material surface performance analysis requirements.
Ring test and reference material correction, resolution 0.01mN/m, equipped with 24-bit AD converter and LVDT displacement Sensor, support automatic stop and averaging functions to ensure test Linearity and repeability accuracy.
The Gamma ball volume replacement method is used to support 0.01-300 g weight range and 0.001g/cm ³ density accuracy, and the immersion depth of the liquid level can be adjusted arbitrarily and the air buoyancy error can be compensated.
Using platinum ring measurement, accuracy of 0.001mN/m, lifting speed of 0~ 300mm/min adjustable, built-in electronic level and automatic measurement program to ensure data accuracy and Repeatability.
Using platinum ring measurement, accuracy of 0.1mN/m, equipped with electronic level and automatic lifting system, eliminate vibration effects, support dynamic measurement and data management, to ensure experimental Repeatability and accuracy.
Using platinum plate method measurement surface tension, accuracy of 0.01mN/m, equipped with electronic level and automatic lifting system, measurement process without vibration interference, support dynamic speed adjustment and a variety of Data analysis functions.
Using platinum ring measurement, accuracy of 0.01mN/m, equipped with electronic level and automatic lifting system to ensure stable and reliable measurement process, support dynamic smooth operation to reduce vibration interference.
Cantilever structure to prevent liquid infiltration, large proportion of chilled down surface uniform heat dissipation, Speed range 60~ 2000rpm, Max. Torque 1850gcm, suitable for viscosity of 10000mPa · s liquid stirring.
Density accuracy of 0.001g/cm ³, maximum weighing 310g, built-in a variety of density reference can be customized settings, support solid liquid powder and other sample testing.
Pellon liquid junction is used to ensure uniform Flow velocity, circular Glass sensitive film fully senses pH value, Measurement range 0~ 14pH, Operating temperature 0~ 60 ℃, the structure is not easy to damage.
Adapted to NS series ColoriMeter, it can measure liquid, sauce and powder samples, realize color data collection of various forms of materials, and expand the application range of the instrument.