Liquid-Liquid Interfacial TensioMeter

The solution interfacial Tensiometer measures the intermolecular forces at the liquid surface or interface and calculates the tension value using the ring method or pendant drop method. It is used to evaluate the effectiveness of surfactants, ink adhesion, and emulsion stability. It provides data support for ink formulation and paint leveling tests.
Selection
Select a matching range based on the viscosity of the liquid to be tested, and determine material resistance by considering the sample's corrosiveness. Constant temperature requirements dictate temperature control accuracy, while ease of operation focuses on the level of automation. Ensure compatibility with industry-standard methods and evaluate maintenance costs and calibration cycles.

Terms

Standards

Instruments

Adopt electromagnetic force closed-loop measurement system, Measurement range 0-400mN/m, resolution +/- 0.1mN/m, automatically read equilibrate value, support high viscosity liquid and interfacial tension test, simple operation without external computer control.

$ 3331.00

Adopt electromagnetic force closed-loop measurement system, accuracy +/- 0.02mN/m, support 0-200mN/m range measurement, with automatic lifting and temperature detection functions, can test high viscosity liquids and dynamic surface tension changes.

$ 4458.00

The manual lifting platform is equipped with fast fine-tuning dual gear, supports platinum plate method and ring method dual Measurement mode, Measurement range 0-400mN/m, error is only +/- 0.1mN/m, can be connected to the computer to display the tension change in real time Linear dispersion.

$ 1531.00

Measurement range 0~ 200mN/m, standard error +/- 0.03mN/m, support real-time Linear dispersion display and thermostatic control, easy and reliable operation.

$ 2207.00

With a fully automatic liquid inlet device, the liquid inlet accuracy reaches 0.001 μL, equipped with SONY high-speed industrial-grade chip and a variety of Measuring methods, it can accurately measure 0-180 ° contact angle and 0-3000mN/m surface tension to meet various material surface performance analysis requirements.

$ 5495.00

Ring test and reference material correction, resolution 0.01mN/m, equipped with 24-bit AD converter and LVDT displacement Sensor, support automatic stop and averaging functions to ensure test Linearity and repeability accuracy.

$ 1397.00

The Gamma ball volume replacement method is used to support 0.01-300 g weight range and 0.001g/cm ³ density accuracy, and the immersion depth of the liquid level can be adjusted arbitrarily and the air buoyancy error can be compensated.

$ 875.00

Using platinum ring measurement, accuracy of 0.001mN/m, lifting speed of 0~ 300mm/min adjustable, built-in electronic level and automatic measurement program to ensure data accuracy and Repeatability.

$ 6260.00

Using platinum ring measurement, accuracy of 0.1mN/m, equipped with electronic level and automatic lifting system, eliminate vibration effects, support dynamic measurement and data management, to ensure experimental Repeatability and accuracy.

$ 2842.00

Using platinum plate method measurement surface tension, accuracy of 0.01mN/m, equipped with electronic level and automatic lifting system, measurement process without vibration interference, support dynamic speed adjustment and a variety of Data analysis functions.

$ 3886.00

Using platinum ring measurement, accuracy of 0.01mN/m, equipped with electronic level and automatic lifting system to ensure stable and reliable measurement process, support dynamic smooth operation to reduce vibration interference.

$ 3886.00

Cantilever structure to prevent liquid infiltration, large proportion of chilled down surface uniform heat dissipation, Speed range 60~ 2000rpm, Max. Torque 1850gcm, suitable for viscosity of 10000mPa · s liquid stirring.

$ 372.00

Density accuracy of 0.001g/cm ³, maximum weighing 310g, built-in a variety of density reference can be customized settings, support solid liquid powder and other sample testing.

$ 525.00

Pellon liquid junction is used to ensure uniform Flow velocity, circular Glass sensitive film fully senses pH value, Measurement range 0~ 14pH, Operating temperature 0~ 60 ℃, the structure is not easy to damage.

$ 96.00

Adapted to NS series ColoriMeter, it can measure liquid, sauce and powder samples, realize color data collection of various forms of materials, and expand the application range of the instrument.

$ 557.00

Articles

UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Blade-coating preparation of hole transport layers for perovskite solar cells.
This article introduces the method of preparing the hole transport layer for perovskite solar cells using the doctor-blade coating technique. The doctor-blade coating method involves spreading the solution evenly on the substrate with a blade to form a thin film, making it suitable for large-scale production.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Salt spray test chamber detects the corrosion resistance of coatings.
The salt spray test chamber accelerates the testing of coating corrosion resistance by simulating a salty and humid environment. It uses atomized sodium chloride solution to form salt spray, which settles inside the constant temperature chamber, and conducts tests under neutral or acidic conditions in accordance with standards.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
The laboratory coating machine provides uniform coating for OCA optical adhesive and AR coating.
The laboratory film coater is a precision instrument used to prepare uniform thin films on substrates, playing a crucial role in the research and development of OCA optical adhesives and AR coatings. It ensures consistent film thickness and prevents defects by precisely controlling parameters such as coating speed, gap distance, and solution viscosity.
Application of Coating Machines in the Fabrication of Functional Layers for Perovskite Solar Cells
This article introduces the application of coating machines in the preparation of functional layers for perovskite solar cells. The performance of perovskite cells depends on the uniformity and quality of thin films, such as the electron transport layer and the light-absorbing layer, which are primarily prepared through solution-based coating methods.