Liquid Crystal Display Low Temperature Thermostatic Bath

The liquid-display low-temperature thermostatic bath cools down through a compressor or semiconductor refrigeration system, combined with a liquid medium and a temperature controller, displaying real-time temperature on an LCD screen. It is used for constant-temperature storage of laboratory samples, cooling of reaction vessels, or low-temperature testing of materials, with a typical temperature range of -40℃ to 100℃.
Selection
When selecting, consider that the temperature range covers experimental needs, temperature control accuracy matches sample sensitivity, and tank size accommodates equipment. Ensure the cooling power meets the required cooling rate. Check safety protections such as leakage and overtemperature protection, compare power consumption and noise data across different brands, and ensure device interfaces are compatible with existing setups.

Terms

Standards

Instruments

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, equipped with 6 liter Tank and 8L/min Pump Flow rate, support liquid level alarm and computer communication, the inner Tank and the box are made of high quality stainless steel.

$ 1108.00

Temperature control accuracy of +/- 0.05 ℃, Display resolution of 0.1 ℃, equipped with 10L/min stirring pump and liquid level alarm function, the inner Tank and the box are made of high-quality stainless steel, support computer communication.

$ 1679.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, equipped with 6 liters stirring pump Flow rate 8L/min, support liquid level alarm and computer communication function, the inner Tank is made of high quality stainless steel.

$ 1021.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, with liquid level alarm and communication function, 6 liters volume with 8L/min pump Flow rate, stainless steel structure.

$ 1468.00

Microcomputer thermostatic Control system, Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, two-way communication and liquid level alarm function, Pump Flow rate 10L/min.

$ 1889.00

Temperature Fluctuation control at +/- 0.05 ℃, Display resolution up to 0.1 ℃, equipped with circulating pump Flow rate 8L/min, support computer two-way communication and liquid level alarm to ensure stable and reliable experiment.

$ 1145.00

Microcomputer thermostatic Control system, Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, two-way communication, equipped with liquid level alarm and 6 liters stirring pump capacity 8L/min.

$ 1206.00

Temperature range -40~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, with liquid level alarm and communication functions, the inner Tank and the box are made of stainless steel, and the pump Flow rate is 10L/min.

$ 3559.00

Viscosity range 0.6~ 6000000mPa · s, repRoducibility +/- 0.5% F. S, supports continuously variable speed and liquid crystal display of various paraMeters, suitable for ultra-low viscosity sample measurement.

$ 1255.00

Rotation speed is accurate and stable with high subdivision stepper motor, viscosity range of 10~ 1000000mPa · s, temperature accuracy +/- 0.1 ℃, support continuously variable speed and direct liquid crystal display, no need for secondary calculation.

$ 1886.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to meet diverse experimental needs.

$ 942.00

Using non-fluorine environmental protection Compressor refrigeration, temperature fluctuation +/- 0.05 ℃, equipped with High Accuracy PT100 Sensor and domestic circulation pump, to avoid its own heat generation affecting the temperature field uniformity, to ensure stable and reliable temperature control.

$ 861.00

The temperature fluctuation is controlled within +/- 0.05 ℃, the non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field, and multiple Safety protection devices are equipped to ensure stable and reliable operation.

$ 1237.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.