Hydrogen sulfide electronic Detector

The hydrogen sulfide electronic detector measures gas concentration through an electrochemical sensor. The sensor reacts with hydrogen sulfide to generate an electrical signal, which is then processed by the circuit to display a numerical value. It is used for leak monitoring and safety protection in places such as chemical plants and wastewater treatment facilities.
Selection
When selecting, consider that the detection range covers the needs of application scenarios, response time meets safety standards, sensor lifespan and calibration cycles affect usage costs, protection rating suits the installation environment, and data logging capabilities facilitate tracking and analysis.

Terms

Standards

Instruments

Electrochemical sensors imported, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring functions.

$ 296.00

Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output interfaces, automatic tracking zero point to prevent drift, adapt to -30~ 50 ℃ working environment.

$ 361.00

Electrochemical sensors imported, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with explosion-proof certification and a variety of signal output interfaces, support remote monitoring and automatic Zero tracking, suitable for hazardous environments.

$ 682.00

Electrochemical sensor principle, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with Intrinsic Safety (IS) design and automatic Zero tracking function, support a variety of signal output and remote monitoring.

$ 361.00

Electrochemical sensors imported, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring, strong anti-interference ability.

$ 682.00

Imported Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds. With intrinsically safe circuit design and explosion-proof certification, support RS485 and 4-20mA dual signal output, automatic Zero tracking and temperature compensation functions to ensure long-term Stability.

$ 296.00

Can simultaneously detect four gases, Electrochemical sensor, Response Time instant, alarm sound up to 80 decibels, operation temperature range -10~ 50 ℃, portable design weighs only 360 grams.

$ 241.00

Electrochemical sensor, Response Time ≤ 15 seconds, with 6000 alarm record query function, super high waterproof design, support sound and light vibration triple alarm, Sensor life 2 years.

$ 146.00

Electrochemical sensor, high detection accuracy, Response Time less than 60 seconds. With IP65 waterproof level, support vibration, sound and light triple alarm, built-in 1500mAh lithium battery can work continuously for more than 8 hours.

$ 145.00

Electrochemical sensor, range 0~ 100ppm, with automatic zero correction and temperature compensation function, support infrared remote control debugging and flameproof design, suitable for dangerous areas.

$ 146.00

Electrochemical sensor, Measurement range 0-100ppm, resolution 1ppm, Response Time less than 30 seconds, explosion-proof structure design to ensure safe and reliable operation.

$ 193.00

Electrochemical sensor technology, range 100ppm, with automatic zero correction and temperature compensation functions, support infrared remote control debugging and 4-20mA and RS485 output, suitable for dangerous areas 1 and 2 zones.

$ 183.00

Using industrial grade Sensor, Response Time less than 30 seconds, accuracy of +/- 3% FS, with 4-20mA and RS485 signal output, shell die-cast aluminum material to meet the requirements of explosion protection, suitable for a variety of harsh environments.

$ 177.00

Electrochemical sensor, detection range 0~ 100ppm, with automatic zero correction and temperature compensation function, support infrared remote control debugging and flameproof design, stable and reliable work.

$ 162.00

Supports simultaneous detection of 4 gases and integrated temperature Humidity monitoring, adopts dual temperature Humidity compensation design, has Internet of Things remote monitoring function, Protection Rating up to IP66, Operating temperature range -40~ 55 ℃.

$ 301.00

Articles

Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Electronic Tensile Testing Machine Measures the Right-Angle Tear Strength of Films
This article explains how to measure the right-angle tear strength of films using an electronic tensile testing machine. During the test, a film specimen with a right-angle notch is first clamped onto the testing machine and stretched at a constant speed. The machine records the changes in force during the tearing process.
Electronic universal testing machine measures film tensile strength.
This article introduces the method of measuring the tensile strength of thin films using an electronic universal testing machine. During the test, the machine applies tensile force to the film sample, records the maximum tensile force and displacement through sensors, and then calculates the tensile strength using a formula.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.
Application of Coulometric Moisture Titrator in Moisture Detection of Electronic Components
Coulometric moisture titrators operate based on the principle of electrolysis, directly calculating the moisture content in samples by measuring the electrolytic charge without the need for calibration. In the field of electronic components, moisture can lead to issues such as corrosion and reduced insulation, making its detection critically important.
The Working Principle and Calibration Method of Electronic Paper Tensile Strength Tester
The electronic paper tensile strength tester is used to measure the mechanical properties of materials such as paper under tension. It is recommended to calibrate the instrument annually and maintain a stable environment along with clean fixtures during daily use.
Electronic tensile testing machine testing the tensile strength of packaging film
This article introduces the method of testing the tensile strength of packaging films using an electronic tensile testing machine. It first explains the importance of tensile strength for packaging films, then details the testing principles, equipment composition, and the necessity of preparing samples according to standards.
Method for Determining Peel Strength of Hot Melt Adhesives Using an Electronic Tensile Tester
This article introduces the standard method for determining the peel strength of hot melt adhesives using an electronic tensile testing machine. The test employs a 180° peel mode, where a sample coated with hot melt adhesive is clamped in the machine's fixtures and peeled at a constant speed. The peel strength is calculated based on the recorded force variations.
Ink solvent resistance tester for alcohol resistance testing.
The ink solvent resistance tester is used to evaluate the alcohol resistance of ink coatings, which is crucial in fields such as packaging printing and electronic product labeling, as inks are often exposed to alcohol-containing cleaning agents.
Phosphor films and quantum dot coatings are uniformly applied using a coating machine.
This article introduces the significance of phosphor films and quantum dot coatings in optoelectronics and display technologies, highlighting that their performance depends on the uniformity, thickness, and density of the coatings.
How to Choose the Right Contact Angle Measuring Instrument Based on Sample Characteristics
Contact angle measurement is a key method for evaluating the wettability of solid surfaces and is widely used in fields such as materials science, coating industry, textile testing, electronic packaging, and environmental monitoring.
Application of Coating Machines in the Fabrication of Functional Layers for Perovskite Solar Cells
This article introduces the application of coating machines in the preparation of functional layers for perovskite solar cells. The performance of perovskite cells depends on the uniformity and quality of thin films, such as the electron transport layer and the light-absorbing layer, which are primarily prepared through solution-based coating methods.