Viscosity Measurement Device

The viscometer obtains viscosity values by measuring the resistance of fluids to rotating or moving components, and is used for quality control and production process monitoring in industries such as coatings and inks.
Selection
When selecting, consider matching the instrument's measurement range with the characteristics of the material to be tested, determine whether a portable or benchtop model is suitable based on the laboratory environment, and evaluate basic functions and automation needs in line with the budget.

Terms

Standards

Instruments

Measurement range is 7~ 40cst, flow hole diaMeter is 3mm, using copper Cup body, in line with ISO2431 standard, suitable for viscosity measurement and equipped with bracket.

$ 196.00

The instrument adopts Precision Platinum Resistance Sensor with temperature control accuracy of +/- 0.1 ℃ and kinematic viscosity measurement range of 0~ 10000mm ²/S, which is suitable for viscosity analysis of various liquids under thermostatic conditions.

$ 1330.00

Applicable to the flow time of not less than 20 seconds viscosity measurement, using aluminum material, capacity 50ml, flow hole diaMeter 5.6mm, can be converted into kinematic viscosity.

$ 167.00

The coaxial cylinder structure is used to achieve accurate viscosity measurement. The sample dosage is only 10-20mL. It is equipped with a removable sample Cup for easy replacement and cleaning. It supports a variety of rotor models to cover a wide range of viscosity.

$ 317.00

Automatically collect viscosity data and generate flow Linear dispersion, support ten historical data comparison analysis, measurement results can be exported to Excel format file, easy data processing and archiving.

$ 349.00

The stainless steel material is durable, the inner wall of the Cup body is smooth to ensure stable Flow velocity, the diaMeter of the flow hole is 2mm, and the viscosity range of 70cSt can be measured. Precision machining ensures measurement accuracy.

$ 190.00

Using 998 stepless speed regulation and automatic scanning functions, Measurement accuracy of +/- 1% F.S., Support real-time viscosity Linear dispersion display and 30 data storage to meet a variety of viscosity measurement needs.

$ 1647.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the aperture is 5.2mm, the viscosity measurement range is 200~ 1200cSt, the outflow time is 20~ 105 seconds, and the liquid viscosity is evaluated by the flow time.

$ 130.00

Measurement range 100~ 300cst, equipped with 5mm flow hole and bracket, using copper Cup body, in line with ISO2431 standard, suitable for Benchtop viscosity testing.

$ 196.00

The stainless steel material is durable and easy to clean, the inner wall of the Cup body is smooth to ensure the stability of Flow velocity, the diaMeter of the precision machining flow hole is 4mm, and the viscosity measurement range is 80~ 700cSt, which meets the requirements of multi-industry standards.

$ 190.00

Viscosity range 0.6~ 6000000mPa · s, repRoducibility +/- 0.5% F. S, supports continuously variable speed and liquid crystal display of various paraMeters, suitable for ultra-low viscosity sample measurement.

$ 1255.00

Adopt 16-bit microcomputer processor and stepper motor high subdivision drive to ensure smooth and accurate speed. Measurement accuracy of +/- 1% F. S, viscosity range covering 1 to 2000000mPa · s, the screen directly displays viscosity, speed, torque and rotor information, easy to operate.

$ 2957.00

Measurement range of 25~ 120cSt, outflow aperture of 2.53mm, suitable for laboratory viscosity testing.

$ 167.00

High subdivision drive stepper motor ensures accurate and stable Rotation speed, Measurement accuracy of +/- 1% F. S, viscosity range of 1~ 1000000mPa · s, LCD display viscosity, Rotation speed and other Multi-ParaMeter, timing function to ensure thixotropic liquid data conformity.

$ 777.00

Using SC4 rotor to achieve 5~ 3300000mPa · s viscosity measurement, temperature control accuracy of +/- 0.1 ℃, support continuously variable speed and automatic lifting system, sample thermostatic uniform and easy to clean.

$ 5023.00

Articles

How to choose the right rotational viscometer?
This article introduces how to select an appropriate rotational viscometer, so you won't be blind when choosing a viscosity measurement instrument!
How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Laboratory blade coating machine is used for analyzing the film-forming characteristics of high-viscosity slurries.
This article analyzes the characteristics of a laboratory doctor blade coater for forming films from high-viscosity slurries. It focuses on the impact of slurry rheological properties on film formation quality.
Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
Stormer viscometer controls the in-can viscosity of latex paint.
This paper introduces the application of the Stormer viscometer in controlling the paint can viscosity of latex paint. Paint can viscosity affects application performance and user experience, with either too high or too low values causing issues.
Rotation rheometer evaluates the atomization performance of water-based paint spraying.
This article introduces how to evaluate the atomization effect of water-based paint spraying using a rotational rheometer. It first explains the two stages of atomization, as well as the importance of rheological parameters such as shear viscosity, storage modulus, loss modulus, and complex viscosity.
Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.