500mL volume reduction pretreatment solution, using Reagent grade chemicals and tamper-proof sealing design to ensure solution freshness, support ElectRode Fast Response, suitable for ORP measurement reduction reaction conditioning.
Provide oxidation pretreatment function, calibrated value at 25 ° C for ORP ElectRode, 500mL large capacity design, with tamper-proof sealing to ensure the freshness and Stability of the standard liquid.
With relative and absolute mV measurement function, Measurement range -999~ 999mV, accuracy +/- 2mV, support automatic end point locking and 1 point offset calibrating, fully waterproof design for use in harsh environments.
Dual channel ORP detection meets standard requirements, automatic temperature compensation and reading lock function, ORP Measurement range +/- 2000mV, resolution 1mV, IP65 Protection Rating is suitable for field use.
Calibrated 240mV@25 ° C, with tamper-resistant sealing to ensure solution freshness, and manufactured in a temperature-controlled environment with Reagent grade chemicals to help quickly check ElectRode performance and determine cleaning needs.
The calibrated value is 470mV, the capacity is 500mL, and the tamper-proof sealing design is adopted to ensure that the standard liquid has a valid period of up to 5 years in the unopened state to ensure the accuracy of calibrating.
Measurement mode with alkalinity and oxidation-reduction potential, support automatic temperature compensation and IP67 waterproof design, can store 120 sets of measurement data, easy to operate.
With 0.002pH Measurement accuracy and automatic temperature compensation, support 1-5 point calibrate and 500 data storage, backlit display and USB interface for outdoor use.
With 0.002pH Measurement accuracy and +/- 0.2mV ORP accuracy, supports 1-5 point calibrating, Automatic ElectRode Diagnostics and 500 sets of Data storage, suitable for outdoor liquid detection and GLP compliance.
Measurement accuracy of 0.002pH, automatic identification of ElectRode type and 500 sets of Data storage, suitable for accurate analysis in a variety of environments.
Support dynamic titration and preset endpoints and other modes, titration analysis Repeatability of 0.20%, Potential Measurement range -1800.0~ 1800.0mV, can store 200 sets of results and comply with GLP specifications.
With pH, ORP and dissolved oxygen three measurement functions, support 1-5 point calibrating and automatic ElectRode diagnosis, can store 500 sets of data and have USB Communication interface, Measurement accuracy of +/- 0.002pH and +/- 0.2mg/L.
Measurement accuracy of 0.2mV and +/- 2000.0mV range, support for automatic end point locking and timed interval readings, built-in calibrated reminders and password protection to ensure data accuracy and operational safety.
With +/- 1000mV wide range measurement and manual two-point Adjustment, support automatic diagnosis ElectRode status and fail-safe alarm system, effectively prevent signal interruption problems.
With 0.002pH Measurement accuracy and 5 point Adjustment, support automatic temperature compensation and ElectRode diagnosis, built-in 500 data storage and GLP compliance.