The ceramic fiber Furnace and inlaid Furnace wire are used, with good heat insulation effect, fast heating and uniform Furnace temperature; with 30-stage program temperature control, over-temperature self-limit and automatic power-off function when opening the door, the temperature control accuracy reaches +/- 1 ℃, safe and convenient.
Category : Muffle Furnace
Brand : LICHEN
SKU : NB022463
Service :The delivery and service By NBCLab.Com
LICHEN SX2-5-12LTP ceramic fiber box type resistance furnace shell is welded with high quality Cold rolled steel plate, and the furnace door is a side open structure. The interior is made of aluminum silicate fiber cotton thermal insulation material, which has large heat storage capacity, short Heating time, low surface temperature rise and low energy consumption. This product is suitable for elemental analysis and determination in laboratories, industrial and mining enterprises, R & D institutions, etc., and heat treatment heating of small steel parts and other metals.
1. Adopting PID temperature control technology, the LCD LCD display clearly displays the set temperature and current temperature. 2, the use of ceramic fiber furnace, heat insulation effect is good, light weight; furnace control conjoined design, easy to operate. 3. The furnace wire is inlaid on the inner wall of the furnace, the furnace temperature is uniform and the heating is fast; the door sealing performance is good, and the heat loss is less. 4. The furnace door is made of stainless steel, which is resistant to corrosion and aging; when the furnace door is opened, the heating power supply is automatically disconnected to ensure safety. 5, cold-rolled steel shell by electrostatic spraying and fine matte treatment, more corrosion resistance, aging resistance. 6. Standard over-temperature self-limiting/self-setting/door-opening and heat-breaking functions, SX2-LTP models come standard with 30-stage program temperature control.
The resistance furnace is powered on by a high-temperature resistance wire as a heat source, and the heat is transferred to the studio through the resistance wire embedded in the inner wall of the ceramic fiber furnace. Using PID intelligent temperature control technology, the real-time temperature is fed back through the temperature sensor, and the controller precisely adjusts the Heating power to achieve fast and uniform heating and High Accuracy thermostatic control.
Laboratories, industrial and mining enterprises, R & D institutions, elemental analysis and determination, small steel heat treatment, metal heat treatment heating
1. Place the equipment in a stable and well-ventilated position and connect it to a power supply (220V) that meets the specifications. 2. Open the furnace door, put the sample to be processed into the working area in the furnace, and pay attention to the stable placement. 3. Close the furnace door and ensure good sealing. 4. Set the required temperature program through the LCD LCD display and controller (the SX2-LTP model supports 30-segment program temperature control). 5. Start the heating, and the equipment starts to heat up according to the set program. 6. Real-time temperature can be observed through the display screen during the heating process. 7. After the work is completed, the furnace temperature is naturally cooled down to a safe temperature before opening the furnace door to take out the sample. 8. Turn off the power supply of the equipment for cleaning and maintenance.
Equipment must be well grounded and installed and operated by professionals. * Furnace working and just finished when the surface temperature is high, do not touch, to prevent burns. * When the furnace door is opened, the heating power will be automatically cut off, please do not force the door to open at high temperature. * Samples and containers must be resistant to high temperatures and must not contain flammable, explosive, corrosion or toxic gases. Do not exceed the recommended operating temperature (500~ 1150 ° C), and do not exceed the rated maximum temperature (1200 ° C) for long-term use. * Equipment should be placed in drying, no corrosion gas, no strong vibration environment. * Regularly check the status of the power cord, furnace and sealing parts, and replace them in time if damaged. * Be sure to cut off the power before cleaning and wait for the furnace body to completely chill down.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.