Ceramic fiber Furnace, good heat insulation, light weight, fast heating; wire inlaid Furnace wall, Furnace temperature uniform; Furnace door open automatic power off, safe and reliable; maximum temperature 1200 ℃, temperature control accuracy +/- 1 ℃.
Category : Muffle Furnace
Brand : LICHEN
SKU : NB022464
Service :The delivery and service By NBCLab.Com
LICHEN SX2-5-12LT ceramic fiber box type resistance furnace shell is made of high quality Cold rolled steel plate welding, and the furnace door is a side open structure. The interior is made of aluminum silicate fiber cotton thermal insulation material, which has large heat storage capacity, short Heating time and low energy consumption. The instrument can be used for elemental analysis and determination in laboratories, industrial and mining enterprises, R & D institutions, etc., and metal heat treatment heating such as small steel parts.
1. Adopting PID temperature control technology, the LCD LCD display clearly displays the set temperature and current temperature. 2, the use of ceramic fiber furnace, heat insulation effect is good, light weight; furnace control conjoined design, easy to operate. 3. The furnace wire is inlaid on the inner wall of the furnace, the furnace temperature is uniform and the heating is fast; the furnace door has good sealing performance and less heat loss. 4. The furnace door is made of stainless steel, which is resistant to corrosion and aging; it automatically disconnects the heating power when opened to ensure safety. 5, cold-rolled steel shell by electrostatic spraying and fine matte treatment, more corrosion resistance, aging resistance. 6. Standard over-temperature self-limiting, self-setting, door opening and heat-breaking functions; SX2-LTP models come standard with 30-stage program temperature control.
The resistance furnace uses high temperature resistance wire as the heating element, and the electric energy is converted into heat energy through the resistance wire. Heat is transferred to the studio through the resistance wire embedded in the inner wall of the ceramic fiber furnace. The PID temperature control system precisely adjusts the Heating power, so that the temperature in the furnace can quickly and evenly reach and stabilize at the set value. The furnace uses aluminum silicate fiber cotton insulation to effectively reduce heat loss.
Laboratories, industrial and mining enterprises, R & D institutions
1. Place the equipment in a stable and well-ventilated position and connect it to a power supply that meets the specifications. 2. Open the furnace door and put the sample to be processed into the working area in the furnace. Note that the sample should not contact the heating element. 3. Close the furnace door and set the required temperature and program (if it is a programmed temperature control model) through the LCD liquid crystal display and controller. 4. Start heating, the equipment starts to heat up, and the PID system will automatically control the heating process. 5. After the heating process, if you need to take out the sample, please wait for the furnace temperature to drop naturally or take appropriate protective measures. Open the furnace door (the heating power is automatically disconnected at this time) and use a special tool to take out the sample. 6. After use, turn off the power of the device.
* Equipment should be placed in a stable, well-ventilated and non-flammable and explosive environment. * The voltage and Power of the connected power supply must match the rated parameters of the equipment (220V, 3kw). * When the furnace door is opened, the heating power will be automatically cut off. This is a Safety protection function, please do not intervene. The maximum temperature is 1200 ° C, and the recommended temperature is 500 to 1150 ° C. Please do not use it over temperature. When inserting or removing samples, thermal gloves and special tools should be worn to prevent burns. * During the heating process and just at the end, the furnace surface temperature may be high, do not touch. * Do not heat flammable, explosive, volatile and toxic gases in the furnace. * Regularly check the equipment wiring and Appearance to ensure safe use.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.