Maximum temperature up to 1200 ℃, temperature control accuracy +/- 1 ℃, Heating time ≤ 30 minutes. Vacuum forming polycrystalline mullite fiber Furnace insulation, special alloy heating wire three-sided heating, Temperature uniformity is good. With multiple Safety protection such as power failure, return delay, and over-rise alarm.
Category : Muffle Furnace
Brand : TaiSiTe
SKU : NB029214
Service :The delivery and service By NBCLab.Com
TAISITE MFLC-2/12T ceramic muffle furnace is a laboratory high temperature equipment with an all-in-one lightweight and compact design. It uses vacuum forming polycrystalline mullite fiber furnace and special nickel-chromium aluminum alloy heating wire for three-sided heating, combined with High Accuracy microcomputer PID temperature control instrument and K-type Thermocouple, to achieve precise temperature control, up to 1200 ℃.
1. Integrated lightweight and compact design. 2. Vacuum forming polycrystalline mullite fiber furnace, good thermal insulation effect. 3. Special alloy heating wire three heating, Temperature uniformity. 4. It has the safety function of opening the door and power failure, and restarting the power delay. 5. Double shell air insulation, low surface temperature. 6. Equipped with an exhaust device, which is conducive to ashing. 7. High Accuracy Microcomputer Temperature Controller Combined with Precision Sensor, Temperature Control accuracy +/- 1 ℃. 8.7 inch color Touchscreen, support finger touch light point setting. 9. With correction, gating, real-time Linear dispersion recording, U disk data export and other ancillary functions. 10. Multiple safety devices: over-rise alarm, menu lock, over-rise prevention, door opening and power failure, restart delay, over-current and leakage protection switch. 11. Parallel side open furnace door design keeps the hot end away from the operator.
Power output of the heating wire of nickel-chromium-aluminum alloy is precisely controlled by the microcomputer PID Control system according to the set temperature program or fixed value, and the furnace is heated on three sides. K-type Thermocouple monitors the temperature in the furnace in real time and feeds it back to the temperature controller to form a closed-loop control to ensure that the furnace temperature is uniform and stable at the set value.
Material ashing, heat treatment, material sintering, laboratory high temperature experiment
The data did not mention specific compliance criteria.
1. Turn on the power supply and turn on the power switch of the device. 2. Set the target temperature or program Linear dispersion by tapping a finger on the 7-inch color Touchscreen. 3. Set the timing time as required (0 to 999.9 hours). 4. Start the heating program and the equipment starts to heat up. 5. During the experiment, the real-time temperature Linear dispersion can be observed through the screen. 6. At the end of the experiment, after the furnace temperature has dropped to a safe range, open the parallel side open furnace door to remove the sample. 7. After use, turn off the power of the device.
• Operating temperature is 1200 ℃, do not use over temperature. • When opening the door, the device will automatically power off. There is a delay in repowering after closing the furnace door. Please pay attention to safety. • Although the surface of the furnace body is designed for heat insulation, there is still a high temperature during work and just after the end. Please do not touch it to prevent burns. • Please ensure that the exhaust hole is unobstructed to facilitate the discharge of gases generated during the ashing process. • Do not heat flammable, explosive or toxic gases in the furnace. Equipment should be placed in a smooth, well-ventilated environment. • Regularly check whether safety devices such as overcurrent and leakage protection switches are normal. • When exporting U disk data, please follow the device instructions. • Before moving or cleaning equipment, be sure to disconnect the power and wait for the equipment to completely chill down.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.