PD array Detector was used to satisfy CIE V (lambda) 2 degree Visual Response. High Accuracy light transmitance and haze data were measured by compensation method. Measurement time was about 1.5 seconds.
Category : Haze Meter
Brand : 3NH
SKU : NB035822
Service :The delivery and service By NBCLab.Com
The YH1200 haze meter (general purpose) can easily implement ASTM D1003 non-compensated and ISO 13468 compensated methods for full light transmitance and haze testing. The open sample compartment supports vertical and horizontal testing to accommodate a variety of samples under test. The PD array detector meets the CIE V (lambda) 2 degree visual Response, and the compensation method measurement ensures High Accuracy and repeability of light transmitance and haze data.
1. Double standard ISO & ASTM to meet the requirements of different user testing standards 2. Easy to operate, equipped with large-size touch operation screen, faster and more accurate measurement, USB data output can be connected with the laboratory system 3. Dynamic measurement, Illuminant detectors and temperature sensors monitor Illuminant and environment changes to ensure reliable data 4. With compensation port, it meets ASTM D1003 non-compensation method and ISO 13468 compensation method to provide more accurate test results 5. easy measurement, open measurement area can be vertical, horizontal test, adapt to more tested samples 6. Quality management software, providing strong haze and light transmitance measurement and analysis software, supporting PC-side data management and test report generation
The YH1200 haze meter adopts the transmission illumination mode, which is 0/D (parallel light illumination, diffuse reflection reception), and uses the integrating sphere size φ 154mm and 400~ 700nm combined LED Illuminant. The PD array detector satisfies the CIE V (lambda) 2 degree visual Response, and realizes High Accuracy light transmitter and haze measurement through compensation method.
Glass Processing, Plastic Processing, Film, Display Processing, Encasement Industry, Liquid Liquid Analysis
ASTM D1003/1044、ISO 13468、ISO 14782、GB/T 2410、JJF 1303-2011、CIE 15.2、JIS K7105、JIS K7361、JIS K 7136
1. Instrument preheating correction 2. Place the sample in the open measurement area, choose vertical or horizontal test 3. Start measurement with large Touchscreen operation 4. Measurement time of about 1.5 seconds, obtain light transmitance and haze data 5. Use the USB interface to output data, connect with the laboratory system or analyze it through quality management software
• Operating Temperature range 0~ 40 ° C (32~ 104 ° F), Storage Temperature range -20~ 50 ° C (-4~ 122 ° F) • Sample thickness should be less than 170mm • Ensure instrument preheating correction before measurement to ensure data accuracy • Power supply with DC 24V, 3A Power Adapter • Regularly check the Illuminant life, Illuminant life is 5 years greater than 3 million measurements
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.