Overview
HEIGHT-LED UVLED Curing Oven (model HTBX-II-FS200200-BL (385nm)) is a UVLED curing device with a wavelength of 385nm, with intelligent safety door protection, automatic and manual control modes, as well as digital dimming, production counting and other functions. The equipment is suitable for heat-sensitive material curing, with energy saving, long life, green environmental protection and other characteristics.
Features
1. Smart security door protection: Turn off the UVLED immediately when opening the door in any mode.
2. Multiple control modes: Provide automatic mode and manual mode to choose from. In automatic mode, it will automatically cure according to the set time. In manual mode, it can be manually turned on and recorded.
3. Function-rich: with digital dimming, production counting, historical data query and other functions.
4. Energy saving and high efficiency: UVLED output band is concentrated, photoelectric conversion rate is high, energy saving and power saving, and curing speed is fast.
5. Wide range of applications: cold light source design, low infrared heat radiation, suitable for heat-sensitive materials.
6. Long lifespan: Long service life, i.e. on and off, no preheating required, and the number of switches does not affect the lifespan.
7. Green and environmentally friendly: meets RoHS standards and does not contain mercury.
Principle
The UVLED Curing Oven irradiates the workpiece with a 385nm wavelength UVLED light source, leveraging its high photoelectric conversion rate and concentrated band to achieve rapid curing. In automatic mode, the device counts down the curing according to the preset irradiation time; in manual mode, the user manually controls the UVLED to turn on and record the time in real time. Air-cooled cooling and PLC control are used to ensure stable operation.
Applications
Thermal material curing
Steps
1. Select the control mode: automatic or manual.
2. Set the irradiation time in automatic mode, and automatically turn off the UVLED after the device countdown.
3. Turn on the UVLED manually in manual mode and record the curing time.
4. Use touch screen operation for parameter setting and digital dimming.
5. The equipment automatically performs production counting and historical data queries.
Notice
• The equipment is protected by a safety door, and the UVLED automatically turns off when opening the door to ensure safe operation.
• Check the Power supply voltage within the range of AC100V-AC240V before use.
• Ensure that the environment temperature is between -10 ° C and 50 ° C, and the relative humidity is between 25% and 80% RH.
• Avoid use in non-specified environments to prevent equipment damage.
• Maintain the cooling system regularly to ensure the air cooling effect.