Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.
Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.
Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.
Colorimetric digestion integrated tube operation, no liquid transfer; water samples for more than 10 measurements to take the average value; ammonia nitrogen detection limit of 0.01mg/L, measurement error ≤ +/- 5%, data storage 30,000.
Colorimetric measurement based on Nasler method, Measurement range 0.00-10 mg/L, providing 100 tests, accurate determination of ammonia nitrogen concentration by Color intensity change.
Measurement range 0.00~ 9.99 ppm, accuracy +/- 0.05 ppm, LED Illuminant 470 nm, automatic shutdown function, compact and portable design.
Optical inspection system using imported cold Illuminant and narrow band interference, Optical inspection stability is less than 0.002A/20min, digestion temperature accuracy +/- 0.5 ℃, support COD and ammonia nitrogen dual paraMeter measurement, can save multiple standard Linear dispersion and data.
Imported cold light source technology life of 100,000 hours, support 0.001mg/L high Sensitivity detection, with digestion Colorimetric integrated tube design to achieve safe and fast measurement, can store 4000 sets of data and support multi-mode power supply.
The imported cold light source has a lifespan of 100,000 hours, a detection limit of 0.05mg/L, supports continuous measurement and standard Measurement mode, and has 4000 sets of data storage and various transmission interfaces.
Purge and trap technology implementation of rapid oxygen-free condensing, temperature control accuracy of +/- 0.5 ℃, support 36 samples at the same time, nitrogen consumption can be adjusted to 330ml/min/sample, digital temperature control to ensure accurate and reliable operation.
Measurement range 0.02~ 25mg/L, resolution 0.01mg/L, Repeatability ≤ 3%, Linearity +/- 3% FS, eliminating human error.
Adopt digestion Colorimetric integrated tube design, detection is safer and more convenient; Minimum display value of 0.001mg/L, Sensitivity is high; Support standard measurement and continuous measurement mode, built-in 4000 sets of data storage, to meet different detection needs.
Colorimetric digestion integrated tube, no need to transfer the liquid, directly display the concentration value; support more than 10 measurements to take the average value, reduce the error; measurement error ≤ +/- 5%, Repeatability ≤ +/- 5%, Optical inspection Stability, life up to 100,000 hours.
Adopting digestion Colorimetric integrated tube design, the detection process is safer and more convenient; the minimum display value is 0.001mg/L, and the Sensitivity is high; it supports a variety of detection paraMeter expansion to meet different water quality testing needs.
Colorimetric integrated tube design, no need to transfer liquid, direct display of concentration value; support more than 10 measurements to take the average value, reduce the error; measurement error ≤ +/- 5%, Repeatability ≤ +/- %, Optical inspection Stability is excellent, data storage up to 30,000.