Particle Size and Zeta Potential Analyzer

The particle size and zeta potential analyzer measures particle size distribution and Zeta potential using laser scattering and electrophoretic light scattering techniques. It is used to evaluate the stability of suspensions and monitor the dispersibility and flocculation behavior of raw materials in industries such as coatings and ceramics.
Selection
When selecting, consider the sample conductivity range, match pH and temperature adaptability; confirm that the particle size detection limit covers requirements; pay attention to automation level and compliance; compare maintenance costs and sample throughput across different models.
Optical inspection principle
test principle
Special purpose

Terms

Standards

Instruments

Measurement range 0.5-3000 μm, maximum resolution 0.1μm, support more than 30 image analysis functions, Particle size distribution and morphology analysis.

$ 5237.00

The image method is used to analyze the particle morphology and particle size, the test range is 1~ 3500 μ m, the system magnification is 4000 times, the automatic segmentation success rate exceeds 93%, and paraMeters such as length-diaMeter ratio and sphericity can be counted.

$ 5366.00

100L/min Sampling flow rate and six particle size channel detection, equipped with long life laser Illuminant and imported air pump, support Touchscreen operation and USB data export function.

$ 10578.00

Using 50L/min Sampling flow rate and six particle size channel synchronous detection, equipped with semiconductor laser Illuminant and Touchscreen control, built-in thermal printer supports real-time data output, Continuous Operating Time up to 5 hours.

$ 8461.00

Test range 0.5~ 3000μm, Maximum magnification 4000 times, can analyze the number of particles, area, circumference, diaMeter, aspect ratio and other distribution data, support a variety of formats of test report output.

$ 6205.00

Using light scattering principle to detect 0.3-10 μ m particle size, Sampling flow rate 28.3L/min, built-in lithium battery supports 6 hours of work, can directly save data to U disk, equipped with thermal printer for on-site output.

$ 3922.00

With six-channel particle size detection and 2.83L/min Sampling flow rate, using laser Illuminant life of over 30,000 hours, support UCL calculation and Built-in Printer, AC-DC dual-use can work continuously for more than 6 hours.

$ 848.00

With 6-channel synchronous detection capability, maximum sampling concentration of 35000 pcs/L, using semiconductor laser Illuminant life of 10 years, built-in battery life of more than 5 hours and support data export printing.

$ 1501.00

With six-channel particle size detection capability, Sampling flow rate 2.83L/min, using long-life laser Illuminant to ensure Stability, built-in thermal printer and support AC and DC power supply, can work continuously for more than 6 hours.

$ 1171.00

Measurement range 0~ 300μm, resolution up to 0.01μm, support multi-layer nickel potential difference analysis, test size optional Φ 2.4mm to Φ 0.8mm.

$ 2978.00

Explosion-proof enclosure design ensures stable operation in harsh environments, can simultaneously monitor multiple particle size dust concentration without changing the cutter, Measurement range 0.01-100 mg/m ³, built-in protective gas curtain to prevent Optical inspection system contamination.

$ 5043.00

Image segmentation technology is used to process overlapping dust and maintain particle prototype; Measurement range is 0.1~ 3000μm, repeatability error ≤ +/- 1%; support custom particle size classification and various image processing methods.

$ 9998.00

With six particle size channel detection capability, sampling capacity of 2.83L/min, built-in lithium battery supports 6 hours of continuous operation, using semiconductor laser Illuminant and color Touchscreen design.

$ 2510.00

The image method is used for particle morphology analysis, the measurement range is 0.1~ 3000μm, the total magnification is 8000 times, and the automatic segmentation and measurement of various geometric paraMeters are supported, and the operation is efficient.

$ 8949.00

Made of hardened stainless steel with an accuracy of 2μm, with a range of 0 to 5000μm and a groove length of 120mm, to ensure the accuracy and durability of particle size measurement.

$ 2442.00

Articles

Laser particle size analyzer measures the particle size distribution of spray powder.
Laser particle size analyzers measure the particle size distribution of sprayed powder based on the principle of light scattering, which is critical for coating uniformity and adhesion. During measurement, the powder must be dispersed in a suitable medium to avoid agglomeration, and tests should be repeated to ensure accuracy.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Automatic Potentiometric Titration for Rapid Detection of Chloride Ion Content in Cement
This article introduces a method for rapidly detecting the chloride ion content in cement using an automatic potentiometric titrator. Excessive chloride ions can corrode steel reinforcement and affect the lifespan of concrete, making accurate detection crucial.
Key operational points for determining the acid value of oils and fats using potentiometric titration.
This article introduces the key operational points for determining the acid value of oils and fats using potentiometric titration. The method principle involves dissolving the oil or fat sample, titrating it with a standard alkaline solution, automatically determining the endpoint based on the potential jump, and then calculating the acid value using the formula.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Laser particle size analyzer analyzes particle size distribution of paint pigments.
This article introduces the application of laser particle size analyzers in analyzing the particle size distribution of paint pigments. It mentions that the particle size distribution of pigments affects the optical properties, stability, and rheological characteristics of coatings.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
Key operational points for determining chloride ion content in water using automatic potentiometric titrators
This article introduces a method for measuring chloride ions in water using an automatic potentiometric titrator. It is based on silver nitrate titration, where the endpoint is automatically determined by a sharp change in electrode potential, offering greater accuracy and higher automation compared to traditional methods.
Sieve Residue Analyzer and Sieve Analysis for Determining Pigment Particle Size Distribution
This article introduces how the sieve residue analyzer measures the particle size distribution of pigments through mechanical sieving.