Calibrate low-temperature thermostatic Baths

The calibration of a low-temperature thermostat involves maintaining a set low-temperature environment in the liquid inside the tank through a refrigeration system and a temperature controller. It is used for calibrating instruments such as thermometers and is commonly employed in low-temperature performance testing of materials.
Selection
When selecting, consider whether the temperature range covers the required specifications, ensure the stability meets the calibration error limits, check that the tank size is compatible with the device under test, and review the manufacturer's calibration certificate and usage and maintenance instructions.

Terms

Standards

Instruments

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

Equipped with high and low temperature thermostatic cell, Temperature range 0-110 ℃, PT100 Probe real-time monitoring, liquid temperature can be corrected to ensure the accuracy of test data.

$ 353.00

With heating and cooling functions, Temperature range -20~ 100 ℃, Fluctuation +/- 0.05~ 0.1 ℃, can be 10-stage program control, to achieve timing thermostatic, heating and cooling.

$ 1372.00

Temperature range -5~ 100 ℃, Temperature Fluctuation and Uniformity up to +/- 0.05 ℃, support a variety of temperature control media, with RS485 interface remote control and multiple safety protection functions.

$ 4592.00

Temperature Fluctuation +/- 0.1 ℃, Temperature range + 5~ 99 ℃, with Sensor fault alarm and over-temperature protection function, built-in circulating water pump supports internal and external thermostatic water flow output.

$ 1161.00

It adopts 96-hole 0.2ml design, supports 100 ℃ high temperature environment, is compatible with a variety of centrifuge tube modules, and meets the thermostatic treatment requirements of different specifications of samples.

$ 148.00

With -5~ 95 ℃ wide temperature range control, temperature accuracy of +/- 0.05 ℃, equipped with 6L/min circulating pump to ensure the temperature uniformity in the Tank, suitable for various thermostatic experimental needs.

$ 1203.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

The temperature range covers -30 to 95 ° C, the temperature control accuracy reaches +/- 0.1 ° C, and is equipped with a 6L/min circulating pump to ensure uniform and stable temperature and meet the needs of various sample thermostatic tests.

$ 1869.00

Temperature range -30~ 100 ℃, temperature fluctuation +/- 0.2 ℃, Air-Cooled Compressor cooling speed, built-in circulation pump can establish a second thermostatic field, compact stainless steel material.

$ 1309.00

With refrigeration and heating bidirectional temperature regulation function, Temperature range -60~ 60 ℃, volume 150L, mirror stainless steel liner and intelligent LCD display, support thermostatic fostering and tissue cell preservation.

$ 3814.00

Temperature range of -25~ 200 ℃ and +/- 0.01 ℃ high resolution, support internal and external circulation and horizontal and vertical two-way mixing, equipped with low level protection and Pt100 temperature sensor, suitable for multi-sample thermostatic testing needs.

$ 1752.00

With refrigeration and heating bidirectional temperature regulation function, Temperature range -20~ 60 ℃, mirror stainless steel liner to prevent atomization, support thermostatic fostering and tissue cell preservation.

$ 2757.00

Equipped with a strong pressure suction pump to provide a thermostatic source for the peripheral Tank, temperature accuracy +/- 0.1 ℃, over-temperature and low temperature sound and light tracking alarm and liquid level protection functions ensure the safety and reliability of the sample.

$ 877.00

The double Compressor and cascade refrigeration system are used to cool down quickly and have low noise; the overall foaming insulation of the Tank body reduces the loss of cooling capacity, the flow rate of the circulating pump is 10L/min to ensure Temperature uniformity, and the Temperature Fluctuation is only +/- 0.05 ℃.

$ 1653.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.