Manual Horizontal Machine Table

The manual horizontal machine applies pressure to the specimen through a handwheel-driven screw to test the compressive strength or hardness of materials. During operation, the specimen is placed between the worktable and the indenter, and the handwheel is turned to bring the indenter into contact with the specimen while reading the pressure value. It is commonly used in laboratory settings for testing the stiffness of paper, the hardness of plastics, and similar applications.
Selection
When selecting, consider that the maximum test force must cover the material testing range, the workbench size should match the specimen specifications, and the indenter type should comply with the testing standard requirements. Check the smoothness of handwheel operation and the accuracy of the dial. Confirm that the body material meets the corrosion resistance requirements of the laboratory environment. Prioritize models equipped with overload protection devices.

Terms

Standards

Instruments

Rated load 1000N, Travel 100mm, manual operation is stable, can adapt to a variety of Force Gauge, suitable for tension and compression load and plug force test, horizontal structure for desktop installation.

$ 256.00

Equipped with fixed load weight and adjustable horizontal table, column lifting space ≤ 140mm, using Glass table anti-rust wear, can accurately adjust the level of the platform, improve the test Repeatability and accuracy.

$ 164.00

The hand wheel drive is used to realize the synchronization of the table movement and the needle drawing circle, the drawing diaMeter can be adjusted from 0 to 10.5mm, and it is equipped with 808 stylus and graded weight.

$ 267.00

Adopting manual sprocket drive structure, Working Travel ≥ 80mm, equipped with four weight combinations, accurate drawing is achieved through replaceable 808 stylus, and different diaMeter graphics are supported.

$ 325.00

Adopt back heating and horizontal forced convection technology to ensure uniform temperature in the studio; Temperature control accuracy up to 0.1 ° C, Fluctuation +/- 0.5 ° C; Sensor fault alarm and over-temperature protection function, Timer Range 0-9999 minutes.

$ 580.00

Adopt back heating structure and horizontal forced convection technology to ensure studio Temperature uniformity. Equipped with High Accuracy Platinum Resistance Sensor, Temperature Fluctuation is only +/- 0.5 ° C, supports 0-9999 minutes timing function, and has multiple Safety protection mechanisms.

$ 490.00

Adopt back heating and horizontal forced convection design, Temperature Fluctuation +/- 0.5 ℃, Temperature range + 10 ℃~ 200 ℃, Sensor fault alarm and 9999 minutes timing function to ensure stable and efficient experiment.

$ 325.00

Adopt back heating horizontal forced convection technology, Temperature Fluctuation +/- 0.5 ℃, Temperature range RT + 10~ 200 ℃. Sensor fault alarm, over-temperature protection and independent temperature limit Control system ensure the safety and reliability of the experiment.

$ 377.00

Using a 360 ° swirl/spin table and a 20W fluorescent lamp with a 60 ° irradiation angle, the effective detection area is 0.0625 square Meters, which can be accurately analyzed against the 0.05~ 5.0mm ² standard dust map.

$ 390.00

Using 360 ° swirl/spin table and adjustable angle lighting system, the standard dust map covers a range of 0.05-5 mm ², and the effective detection area is 0.0625 m2, meeting the needs of accurate dust analysis.

$ 320.00

Suitable for paper or Cardboard dust degree determination, in line with national standards, the effective area of the table is 0.0625 square Meters and can be 360 ° swirl/spin, and the standard dust map area is 0.05~ 5.0mm ².

$ 361.00

Equipment supports vertical and horizontal combustion test, can set combustion and extinguishing time and repeability times, automatic stop test, Internal dimensions 305 * 355 * 610mm, suitable for a variety of organic materials.

$ 691.00

The table temperature adjustment technology is used to effectively suppress temperature overshoot, the temperature control accuracy reaches +/- 1 ℃, and supports four-station synchronous operation, Max. stirring Capacity 5L × 4, Speed range 100-1600rpm.

$ 724.00

Glass workbench is not easy to abrasion and flatter for a long time, equipped with fixed load weight to ensure accurate counterweight, adjustable level of working platform to improve Test accuracy, column lifting space up to 180mm.

$ 227.00

Adopt horizontal oscillation mode, Frequency 0-240rpm continuously adjustable, stable work and low noise, equipped with 340 * 250mm tray to meet the needs of a variety of experimental containers.

$ 199.00

Articles

Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
The heating film coater applies thick-film resistor paste onto the ceramic substrate.
The heating coating machine is used to apply thick film resistor paste on ceramic substrates. It reduces the viscosity of the paste through a heating platform and ensures uniform coating in conjunction with the coating head.
Vacuum adsorption coating table solves the problem of film substrate wrinkling.
The vacuum adsorption coating platform uses a microporous array connected to a vacuum system beneath the tabletop to create a pressure difference, tightly adsorbing the film substrate. This ensures it remains flat during the coating process, preventing wrinkles that could lead to uneven coating.
How to Utilize a Vacuum Adsorption Coating Machine to Solve the Slippage Issue During Coating on Flexible PET Substrates
The vacuum adsorption coating machine stabilizes the flexible PET substrate on the coating platform through negative pressure, effectively addressing the slipping issue during the coating process. Slipping is primarily caused by factors such as the smooth surface of PET, insufficient friction, and interference from coating pressure, which can lead to uneven coatings.
Effect of Platform Temperature on Surface Drying Time of Waterborne Polyurethane Coatings in Heated Automatic Film Applicators
This study investigates the influence of the platform temperature of a heated automatic film applicator on the surface drying time of waterborne polyurethane coatings. The experiments reveal that as the platform temperature increases, the surface drying time of the coating significantly decreases, showing a negative correlation between the two.
Vibration test bench simulates transport packaging environment testing.
Vibration testing tables simulate the vibration environment during transportation in the laboratory to test packaging and evaluate its protective performance. The tests primarily follow domestic and international standards, simulating sinusoidal or random vibrations that cover typical transportation conditions such as road and rail.
Performance Comparison and Selection Guide Between Electric Vibration Tables and Hydraulic Vibration Tables
Electric shakers and hydraulic shakers are two commonly used vibration testing devices, each with different working principles. When selecting a model, factors such as test frequency, specimen weight, displacement requirements, and cost need to be considered.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
Selection Guide How to Choose a Vibration Test Bench Based on Testing Standards
When selecting a vibration test system, start by carefully reviewing the test standards to clarify key parameters such as frequency range, thrust force, displacement, acceleration, and vibration type. Then, based on the standard requirements, calculate the required thrust force, match the specifications of the shaker and amplifier, and select an appropriate control system.
Key Points for Operating Vacuum Adsorption Coating Machines on Flexible Substrates
Vacuum adsorption coating technology is a key process in flexible electronics, functional coatings, and the preparation of new materials. This technique uses vacuum negative pressure to ensure that flexible substrates are smoothly and evenly adsorbed onto the coating platform. Combined with precision coating, it effectively reduces defects such as wrinkles and bubbles, thereby enhancing the uniformity and consistency of the coating.
Detailed Explanation of Laboratory Vacuum Adsorption Platform: Flatness is the Cornerstone of Successful Coating
The vacuum adsorption platform is a key device in coating experiments, which stabilizes the substrate by negative pressure adsorption, providing a reference plane for coating. The flatness of the platform surface is crucial, as even minor deviations can lead to defects such as uneven coating thickness or the appearance of streaks.
Surface Tensiometer: Interpreting the Invisible Forces on Liquid Surfaces
Surface tension is the contractile force generated by the uneven forces acting on molecules at the liquid surface, influencing phenomena such as droplet formation and capillarity. Surface tension meters measure this force using techniques like the Wilhelmy plate method, the platinum ring method, or the pendant drop method. Their core components include force sensors, sample stages, and data processing systems.
What are the differences between horizontal airflow and vertical airflow in a clean bench?
Purification workbenches primarily employ two types of air supply methods: horizontal and vertical. In horizontal air supply, the airflow is parallel to the work surface, while in vertical air supply, the airflow moves from top to bottom, forming a laminar barrier. The selection should be based on a comprehensive consideration of experimental needs, sample characteristics, and safety requirements.
For electromagnetic vibration tables, whether to choose sweep frequency or fixed frequency testing standards for simulating transportation is crucial; do not make a random selection if you are unsure.
The electromagnetic vibration table is used to simulate transportation vibrations and test the durability of products and packaging. There are two types of tests: fixed-frequency and sweep-frequency. The selection should be based on the test objectives and relevant standards to avoid arbitrary choices. For new products, it is recommended to first conduct a sweep-frequency test to identify resonance points, followed by fixed-frequency tests as needed.