Maximum temperature of 1700 ℃, Furnace volume of 12 liters, using silicon molybdenum Rod heating and aluminum oxide fiber Furnace to ensure uniform heating and durability, support inert or reducing gas environment, suitable for high temperature material processing.
Operating temperature up to 1400 ℃, Furnace volume of 12 liters, using silicon carbon Rod heating element and double chill down system, support inert gas and reducing gas environment material sintering process.
Explosion-proof enclosure design ensures stable operation in harsh environments, can simultaneously monitor multiple particle size dust concentration without changing the cutter, Measurement range 0.01-100 mg/m ³, built-in protective gas curtain to prevent Optical inspection system contamination.
Cuboid studio to improve volume utilization, drying time reduced by more than 40%; Temperature range RT + 10~ 200 ℃, temperature fluctuation +/- 1 ℃, easy to clean stainless steel material and inert gas environment to prevent oxidation.
Operating temperature of 1400 ℃, Furnace volume of 36 liters, aluminum oxide fiber Furnace and double chill down system, support material sintering process in inert gas environment.
It can be tested in the sewage environment, the speed range is 0.01-10 m/s, the error is less than or equal to 1.5%, the measuring Rod positioning measurement method is adopted, the structure is simple and light, the Degree of automation is high and stable and reliable.
It adopts flameproof structure design, supports 4-20mA, RS485 and switch output, Response Time ≤ 30 seconds, Detection error ≤ +/- 3% F.S. It can be operated by remote control without opening the lid, with sound and light alarm function, suitable for dangerous environment gas monitoring.
Temperature range -5~ 99.99 ℃, Temperature Fluctuation +/- 0.05 ℃, Temperature resolution 0.01 ℃, support internal and external circulation system, Tank volume 5/6L, provide a stable environment for temperature sensitive experiments.
Temperature range RT + 3~ 65 ℃, accuracy +/- 0.3 ℃, equipped with ultraviolet sterilization lamp and deoxygenation catalyst, can quickly form an anaerobic environment and maintain more than 12 hours, the operation room is made of stainless steel, flexible and convenient to use special gloves.
Adopting stainless steel frame and 10mm float plate Glass structure, the gas leakage rate is less than 0.5% of the box volume at 1000 Pa per minute, and the surface is smooth and clean without adsorption, ensuring accurate and reliable test data.
Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.
Vacuum environment significantly reduces the boiling point of liquid, suitable for heat-sensitive substances; drying Temperature range RT + 50~ 200 ℃, Vacuum Level < 133Pa; inert conditions prevent oxide explosion, powder sample stability does not move.
Using double-decked Vacuum Glass observation window and SUS304 stainless steel inner box, temperature control accuracy +/- 0.5 ℃, support programmed test and multi-stage programming, with Data storage and communication functions to meet the demanding environment testing needs.
Detection of oxygen concentration 0~ 25% range, resolution of 0.1%, Response Time ≤ 15 seconds, Portable design, suitable for a variety of environment monitoring needs.
Adopting double-decked Vacuum Reinforced Glass observation window and SUS304 stainless steel inner box, the temperature control accuracy reaches +/- 0.5 ℃, supports program test and Data storage function, and meets the strict environment Reliability verification requirements.