Explosion-proof vibration measuring instrument

Explosion-proof vibration measuring instruments convert mechanical vibrations into electrical signals through piezoelectric sensors, monitoring equipment operating conditions in flammable and explosive environments. They are used for vibration detection of rotating machinery in hazardous areas such as chemical plants and oil fields to prevent equipment failures.
Selection
When selecting, consider matching the explosion-proof rating with the hazardous area on site, ensuring the measurement range covers the equipment's vibration frequency, the sensor can withstand the environmental temperature, the data interface is compatible with the existing system, and the protection rating suits the on-site working conditions.

Terms

Standards

Instruments

Using explosion-proof composite explosion-proof technology, pumping rate of 4L/S, noise only 63dB, equipped with gas ballast valve can remove a small amount of water vapor, safe and reliable for dangerous environment.

$ 701.00

Using explosion-proof composite explosion-proof technology, pumping rate 2L/S, noise as low as 63dB, equipped with gas ballast valve can extract a small amount of water vapor, safe and reliable.

$ 517.00

Using explosion-proof composite explosion-proof technology, pumping rate 8L/S, noise as low as 66dB, equipped with gas ballast valve can extract a small amount of water vapor, suitable for flammable and explosive dangerous places.

$ 1024.00

Adopting explosion-proof, burn-seal, intrinsically safe composite explosion-proof technology, with anti-suction valve and gas ballast valve, the pumping rate is 16m ³/h, the ultimate pressure is 0.005mbar, and the noise value is 58dB (A).

$ 1063.00

The use of explosion-proof composite explosion-proof technology to ensure safe operation, pumping rate of 15L/S and noise only 66dB, equipped with gas ballast valve can handle a small amount of water vapor, compact suitable for use in hazardous environments.

$ 1308.00

It adopts explosion-proof composite explosion-proof technology to ensure safe operation. It is equipped with an anti-suction valve to prevent oil from being sucked back. It is equipped with a gas ballast valve to adjust the Vacuum Level. The pumping rate is 24m ³/h, and the noise value is 58dB.

$ 1192.00

With 3000 times/min and 6000 times/min two vibration frequencies, the amplitude can be continuously adjusted between 0mm and 3mm, supporting three modes of subtle vibration, intermittent vibration and continuous vibration, suitable for ≤ 325 mesh material analysis.

$ 811.00

The explosion-proof composite explosion-proof technology is used to ensure safe operation, with anti-suction valve and gas ballast valve, the pumping rate is 48m ³/h, and the ultimate pressure is as low as 0.005mbar, which is suitable for dangerous environments.

$ 1889.00

Using flameproof composite explosion-proof technology, the pumping rate is 1L/S, the ultimate pressure can reach 0.006mbar, and the noise is as low as 63dB, which is suitable for flammable and explosive environments.

$ 462.00

Using explosion-proof composite explosion-proof technology, explosion-proof mark ExdIBT4, pumping rate 90m ³/h, limit pressure as low as 0.005mbar, noise only 58dB, suitable for hazardous environments.

$ 2922.00

Adopt compound explosion-proof technology, pumping rate 0.5L/S, noise value 62dB, equipped with gas ballast valve can extract a small amount of water vapor, safe and reliable to adapt to harsh environment.

$ 462.00

Intrinsically safe explosion-proof design, up to CT4 grade, equipped with explosion-proof Sensor and display. Table size 410x510mm, weighing range 110kg, accuracy 10g, stable structure, support external calibrating and a variety of functions.

$ 190.00

Adopt flameproof composite explosion-proof technology to ensure safe operation, with a pumping rate of 6L/S and a noise of only 64dB. Equipped with a gas ballast valve to handle a small amount of water vapor, it is compact and easy to install and maintain.

$ 817.00

The pumping rate is 36m ³/h, the ultimate pressure is 0.005mbar, the anti-suction valve is used to prevent oil from being sucked back, the gas ballast valve can adjust the Vacuum Level and process water vapor, and the composite explosion-proof technology ensures safe operation.

$ 1631.00

Suitable for flammable and explosive environment, explosion-proof grade ExdIBT4, pumping rate 8m ³/h, limit pressure as low as 0.005mbar, equipped with anti-suction valve and gas ballast valve to ensure safe and reliable operation.

$ 882.00

Articles

Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Vibration test bench simulates transport packaging environment testing.
Vibration testing tables simulate the vibration environment during transportation in the laboratory to test packaging and evaluate its protective performance. The tests primarily follow domestic and international standards, simulating sinusoidal or random vibrations that cover typical transportation conditions such as road and rail.
The impact of temperature, humidity, and vibration coupling in a three-environmental test chamber on the structural fatigue of products.
This article explores the impact of the coupled effects of temperature, humidity, and vibration in a three-comprehensive test chamber on the structural fatigue of products. It explains how such a coupled environment accelerates the degradation of material performance, such as high temperature and humidity reducing the material's fatigue limit, while vibration promotes crack propagation.
Performance Comparison and Selection Guide Between Electric Vibration Tables and Hydraulic Vibration Tables
Electric shakers and hydraulic shakers are two commonly used vibration testing devices, each with different working principles. When selecting a model, factors such as test frequency, specimen weight, displacement requirements, and cost need to be considered.
Selection Differences Between Random Vibration and Sine Vibration Tests
This article primarily discusses the differences between random vibration and sinusoidal vibration tests. Sinusoidal vibration uses a periodic signal at a single frequency, making it suitable for identifying resonance points and conducting fatigue tests. Random vibration, on the other hand, employs a broadband random signal to simulate real-world environments, such as transportation jolts, making it more appropriate for reliability acceptance testing.
Key points for selecting a multi-factor comprehensive test chamber with integrated temperature, humidity, vibration, and altitude systems
The multi-factor comprehensive test chamber integrates four environmental stresses: temperature, humidity, vibration, and altitude (low pressure), used to simulate the reliability of products under complex environmental conditions.
Selection Guide How to Choose a Vibration Test Bench Based on Testing Standards
When selecting a vibration test system, start by carefully reviewing the test standards to clarify key parameters such as frequency range, thrust force, displacement, acceleration, and vibration type. Then, based on the standard requirements, calculate the required thrust force, match the specifications of the shaker and amplifier, and select an appropriate control system.
For electromagnetic vibration tables, whether to choose sweep frequency or fixed frequency testing standards for simulating transportation is crucial; do not make a random selection if you are unsure.
The electromagnetic vibration table is used to simulate transportation vibrations and test the durability of products and packaging. There are two types of tests: fixed-frequency and sweep-frequency. The selection should be based on the test objectives and relevant standards to avoid arbitrary choices. For new products, it is recommended to first conduct a sweep-frequency test to identify resonance points, followed by fixed-frequency tests as needed.