Compact Coating Mixer

The paint mini mixer uses a motor to drive the blade rotation, generating shear force to uniformly mix the paint components. It is used for dispersing, blending, and homogenizing small batches of paint samples in the laboratory, and can handle fluid materials such as water-based paints, solvent-based paints, and inks.
Selection
When selecting, consider matching the sample viscosity with the motor power, determine the stirring rod length based on container dimensions, use stainless steel material to accommodate corrosive materials, ensure the speed control function meets the needs of different process stages, and pay attention to the compatibility of the fixing device with the container.

Terms

Standards

Instruments

Two Operating Modes, point and continuous, fixed speed up to 3000rpm, track diaMeter 4mm, compact and lightweight only 3.5kg, engineering plastic shell corrosion resistance, stable operation.

$ 141.00

Fixed Rotation speed 2800RPM, eccentric spherical shaft design for easy installation of vibration head, reinforced engineering plastics and TPU table, acid and alkali wear resistance, support point and continuous Operating Mode.

$ 189.00

Adopting stepless speed regulation technology, the maximum speed reaches 2800RPM, and the eccentric spherical shaft design ensures uniform mixing; the body adopts reinforced engineering plastics, and the work surface is made of wear-resistant TPU material, which is acid-alkali and collision-resistant, suitable for high-speed work.

$ 212.00

Adopt stepless speed regulation design, Speed range up to 2800rpm, support point and continuous two Operating Modes, equipped with high-performance low-noise shaded pole motor to ensure rapid and effective mixing, compact structure and easy operation.

$ 180.00

With a wide range of 0-2800rpm speed regulation, support point and continuous operation mode, no need to add magnetic components to avoid pollution, suitable for mixing a variety of utensils, compact structure and easy operation.

$ 141.00

32 5ml centrifuge tubes can be installed vertically on both sides, using a vertical installation design, suitable for HT-X100 swirl/spin Mixer, improving Sample Handling efficiency.

$ 149.00

Fixed speed 2800RPM, eccentric spherical shaft design to ensure uniform mixing; TPU material work surface wear-resistant and corrosion-resistant, suitable for a variety of testtube specifications; compact size and low power consumption, suitable for long-term high-speed work.

$ 177.00

Adopting stepless speed regulation technology, the maximum speed is 2800RPM, the eccentric spherical shaft design is easy to install, the TPU countertop is wear-resistant and corrosion-resistant, compact in size and low in noise, suitable for high-speed mixing operations.

$ 198.00

Double-sided horizontal mounting design can accommodate 40 centrifuge tubes simultaneously, compatible with 1.5ml and 2.0ml specifications, suitable for swirl/spin Mixer for efficient Sample Handling.

$ 149.00

Ultra-small portable design can be put into the pocket, equipped with protective rubber cover to prevent falling; the use of a No. 5 battery can continuously measure tens of thousands of sets of data, that is, there is no need to wait for the test; the use of special microcomputer control to eliminate external light interference, to ensure 0.1% resolution High Accuracy measurement.

$ 444.00

Adopting rotary oscillation design, Frequency 3000rpm, pendulum amplitude 5mm, suitable for small containers such as testtube and Colorimetric tube, it can efficiently handle the experimental requirements of large chemical reactions and few solutions.

$ 125.00

The eccentric spherical shaft design ensures uniform mixing, the fixed Rotation speed is 2800RPM to achieve fast vortex mixing, the TPU material work surface is wear-resistant and corrosion-resistant, the structure is compact, the noise is low, and the power consumption is only 60W.

$ 223.00

Using 60 ° Measurement Angles and 0~ 199.9GU Measurement range, with 10 * 20mm Measuring Area and +/- 1.2GU Indication Error, the whole set of instruments is designed in one piece and the measuring port has anti-scratch coating.

$ 364.00

Using the rotary oscillation mode, Oscillation Frequency up to 3000 rpm, swing amplitude of 5mm, through smooth contact to achieve rapid mixing, speed can be adjusted with pressure, suitable for a variety of laboratory applications.

$ 133.00

Using stepless speed regulation technology, Speed range 0~ 2800rpm, turnover diaMeter 4mm, support point and continuous Operating Mode, high performance motor to ensure rapid mixing and low noise.

$ 208.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.