High Temperature Circulator

The high-temperature circulator provides a stable high-temperature environment for reactors or equipment by heating the medium and circulating its flow. It is used for chemical reactions and material aging tests in laboratories to ensure temperature uniformity.

Instruments

With heating and cooling functions, Temperature range -20~ 100 ℃, Fluctuation +/- 0.05~ 0.1 ℃, can be 10-stage program control, to achieve timing thermostatic, heating and cooling.

$ 1372.00

Can work at room temperature to 300 ℃ range, using high temperature centrifugal jet circulation pump, head up to 5 Meters, equipped with PID automatic temperature control, digital resolution 0.01 ℃, Temperature Fluctuation +/- 0.05 ℃, domestic circulation system to achieve a high degree of uniform temperature field.

$ 914.00

It can precisely control the temperature in the range of room temperature to 300 ° C, Temperature Fluctuation +/- 0.05 ° C, equipped with high temperature centrifugal jet circulation pump, head 5 Meters, support the internal and external circulation system, and achieve a highly uniform temperature field.

$ 672.00

Temperature range Room temperature to 300 ℃, Temperature Fluctuation +/- 0.05 ℃, support water-oil dual-use medium; High temperature centrifugal pump head 5 Meters, to achieve uniform temperature field inside and outside circulation, built-in multiple Safety protection devices.

$ 1166.00

With heating and cooling functions, Temperature range -10~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, support 10-stage program control and external communication, pump Flow rate 12L/min, suitable for internal and external circulation applications.

$ 1146.00

Temperature control accuracy of +/- 0.05 ℃, support room temperature to 300 ℃ range of water and oil dual-use, equipped with high temperature centrifugal pump head 5 Meters, domestic circulation system to achieve uniform temperature field.

$ 825.00

Temperature range room temperature to 300 ℃, Temperature Fluctuation +/- 0.05 ℃, the use of non-heat centrifugal circulation pump to avoid their own heat impact temperature field, with low water level protection and alarm function.

$ 2061.00

Temperature range from room temperature to 300 ℃, Temperature Fluctuation +/- 0.05 ℃, using non-heat centrifugal circulating pump and PID automatic temperature control to achieve a highly uniform temperature field, with a variety of Safety protection functions.

$ 2510.00

It can work in the range of room temperature to 300 ° C, with a pump Flow rate of 15L/min, with internal and external circulation systems to achieve a highly uniform temperature field, support multi-stage program temperature control and Safety protection functions.

$ 1506.00

Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, using proportional refrigeration technology and PID control, support internal and external circulation and programmed operation, with low liquid level and over temperature protection, suitable for a variety of application environments.

$ 2287.00

Adopt proportional refrigeration and PID control technology, support 30-stage program control, Temperature Fluctuation +/- 0.05K, with multiple safety protections such as water shortage protection and overheating and overflow, and the pump Flow rate reaches 12L/min.

$ 1519.00

Adopt proportional refrigeration and PID control technology, temperature control accuracy of 0.05K, support 30 program settings, equipped with maintenance-free pressure pump and multiple Safety protection system, working noise is less than 45 decibels.

$ 2163.00

With proportional refrigeration and PID control technology, temperature control accuracy of 0.05K, support 30-stage program control. Adopt maintenance-free pressure pump, maximum Flow rate 22L/min, integrated multiple Safety protection system.

$ 2050.00

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

Temperature range -20 ℃ to 150 ℃, equipped with pressure/suction pump and Pt100 Sensor, supports multi-stage program control and external temperature sensor, with hardware over-temperature protection and multiple safety modes.

$ 977.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.