Low-temperature liquid Bath

The low-temperature liquid bath maintains a constant low temperature of the liquid inside the tank through a refrigeration system, and is used for sample cooling or constant-temperature experiments. It is commonly used in fields such as low-temperature performance testing of materials and temperature control for chemical reactions.
Selection
When selecting, focus on the temperature range and precision requirements, consider the compatibility of tank capacity and sample size, check the cooling power and cooling rate, confirm liquid compatibility and safety protection features, and evaluate the device dimensions and laboratory space suitability.

Terms

Standards

Instruments

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, equipped with 6 liter Tank and 8L/min Pump Flow rate, support liquid level alarm and computer communication, the inner Tank and the box are made of high quality stainless steel.

$ 1108.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, the temperature fluctuation is +/- 0.05 ℃, and it has low water level protection and Compressor multiple protection functions to ensure the safety and stability of the experiment.

$ 1067.00

Temperature range -40~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, with liquid level alarm and communication functions, the inner Tank and the box are made of stainless steel, and the pump Flow rate is 10L/min.

$ 3559.00

Temperature Fluctuation control at +/- 0.05 ℃, Display resolution up to 0.1 ℃, equipped with circulating pump Flow rate 8L/min, support computer two-way communication and liquid level alarm to ensure stable and reliable experiment.

$ 1145.00

Microcomputer thermostatic Control system, Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, two-way communication and liquid level alarm function, Pump Flow rate 10L/min.

$ 1889.00

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, support computer two-way communication and liquid level alarm, the inner Tank and the box are made of stainless steel to ensure stable and reliable operation.

$ 1555.00

Microcomputer thermostatic Control system, Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, two-way communication, equipped with liquid level alarm and 6 liters stirring pump capacity 8L/min.

$ 1206.00

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, with liquid level alarm and communication function, 6 liters volume with 8L/min pump Flow rate, stainless steel structure.

$ 1468.00

Temperature range -5~ 100 ℃, Temperature Fluctuation and Uniformity up to +/- 0.05 ℃, support a variety of temperature control media, with RS485 interface remote control and multiple safety protection functions.

$ 4592.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to meet diverse experimental needs.

$ 942.00

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, equipped with 6 liters stirring pump Flow rate 8L/min, support liquid level alarm and computer communication function, the inner Tank is made of high quality stainless steel.

$ 1021.00

Using non-fluorine environmental protection Compressor refrigeration, temperature fluctuation +/- 0.05 ℃, equipped with High Accuracy PT100 Sensor and domestic circulation pump, to avoid its own heat generation affecting the temperature field uniformity, to ensure stable and reliable temperature control.

$ 861.00

The temperature fluctuation is controlled within +/- 0.05 ℃, the non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field, and multiple Safety protection devices are equipped to ensure stable and reliable operation.

$ 1237.00

The non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.05 ℃. Safety protection devices are equipped to ensure stable operation of the equipment and support external circulation functions to meet diverse experimental needs.

$ 1611.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Optimization of mixing efficiency of vortex mixer in liquid-liquid microextraction
This paper explores how to enhance mixing efficiency in liquid-liquid microextraction by adjusting the operating parameters of a vortex mixer.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Differential Scanning Calorimetry measures the phase transition temperature of liquid crystal polymers.
This article introduces the method of determining the phase transition temperature of liquid crystal polymers using a differential scanning calorimeter. The differential scanning calorimeter analyzes the phase transition behavior of materials by comparing the heat difference between the sample and a reference material, recording the heat flow curve during temperature changes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.