Solid Light Transmittance Meter

The solid transmittance meter measures the transmittance by illuminating a sample with a light source and detecting the ratio of transmitted light intensity to incident light intensity. It is used to measure the transparency of solid materials such as plastics and glass, and to evaluate their optical properties in quality control.
Selection
When selecting a solid-state light transmittance meter, it is essential to consider the compatibility of sample size with the instrument's fixture, ensure the wavelength range covers application needs, verify that accuracy meets standard requirements, assess ease of operation for daily use environments, and evaluate maintenance costs along with brand service support.

Terms

Standards

Instruments

It adopts parallel light path design, supports 47mm Film thickness material test, and can simultaneously measure ultraviolet 365nm, infrared 940nm and visible light transmittance. It has real-time self-calibrating function, and the operation is simple and fast to display three results.

$ 341.00

The three-in-one optical path design can simultaneously measure the transmittance of blue light at 430nm, purple light at 395nm and visible light, and the test aperture Φ 1mm is suitable for large thickness materials. Real-time dynamic self-Adjustment ensures accurate data.

$ 373.00

Using 380-1000nm Light spectrum instrument to achieve comprehensive measurement of total light transmitance, haze, color coordinates, etc. Precision wavelength +/- 0.3nm, built-in integrating sphere coating stable and durable, a variety of fixtures to meet the needs of liquid solid sample testing.

$ 20729.00

Utilizing a 360-780nm composite full-spectrum LED light source, equipped with a 256-pixel CMOS detector and a concave grating, it achieves spectral acquisition at 10nm intervals, supporting micro-transmittance measurements and a variety of optical index tests.

$ 6851.00

The three Illuminants share a test hole, and the 380nm-760nm visible light, 940nm infrared and 365nm ultraviolet transmittance can be obtained in one measurement. The parallel light design can test large thickness materials, and the 1mm test aperture is suitable for small size samples.

$ 373.00

Adopt three-in-one parallel light path design, one measurement of visible light, infrared and ultraviolet transmittance; test aperture 1.3mm, suitable for small size and thick materials; Automatic calibration and large capacity storage function.

$ 361.00

It can simultaneously test infrared, ultraviolet and visible light transmittance, and support the evaluation of total solar energy barrier rate. Using point array color screen visual display, the fuselage is lightweight and portable, with real-time dynamic Adjustment, Measurement accuracy is better than +/- 2%.

$ 170.00

Using 360~ 780nm composite full Light spectrum LED Illuminant, equipped with 256 pixel CMOS Detector, measurement wavelength range of 360~ 780nm, interval of 10nm, to achieve haze, transmittance, chroma and other Optical inspection indicators of accurate testing.

$ 6980.00

The three-in-one optical path measures the transmittance of three wavelengths at one time, the test aperture is 1mm to adapt to small-sized materials, and the parallel light design ensures stable measurement of thick materials, with an accuracy of +/- 2% and a resolution of 0.1%.

$ 361.00

Optical inspection components imported, measurement range 0.0-99%, accuracy ≤ 2%, with single and continuous two measurement modes, support MAX Maximum, MIN Minimum, average statistics, can store 800 sets of data and connect to computer communication.

$ 344.00

Using 3-in-1 optical path design, one hole can simultaneously measure three wavelengths transmittance. Equipped with 1mm test aperture and Automatic calibration function, support 850nm/940nm infrared and 550nm visible light measurement, accuracy of +/- 2%.

$ 373.00

Support ultraviolet-visible infrared three-light transmitance measurement, accuracy of +/- 2%, single continuous Measurement mode, thickness measurement capacity of 10mm, portable design weighing only 120g for easy on-site use.

$ 365.00

Ultra-small portable design can be put into the pocket, equipped with protective rubber cover to prevent falling; the use of a No. 5 battery can continuously measure tens of thousands of sets of data, that is, there is no need to wait for the test; the use of special microcomputer control to eliminate external light interference, to ensure 0.1% resolution High Accuracy measurement.

$ 444.00

With 0-100% measurement range and 0.1 resolution, accuracy +/- 2%, support ultraviolet-visible infrared three-band light transmitance measurement, swirl/spin Sensor for multi-angle testing, portable design for easy field use.

$ 385.00

Measurement range 0~ 100%, resolution 0.1, using LED Illuminant, support single or continuous measurement, solid and portable structure, can output data through RS-232 data line.

$ 272.00

Articles

Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Haze Transmittance Meter for Evaluating Optical Clarity of Contact Lenses
This article introduces how a haze transmittance meter is used to evaluate the optical clarity of visual correction products such as contact lenses. Haze refers to the blurriness caused by light scattering, while transmittance reflects the material's ability to transmit light. Together, these two factors determine clarity.
Transmittance Meter Selection Guide: Principles for Matching Light Sources and Samples
This article introduces how to select the light source for a transmittance meter based on sample characteristics. The types of light sources include halogen tungsten lamps, LEDs, and lasers, which are suitable for wide-band, monochromatic, or high-precision measurements, respectively.
Contact angle measuring instrument measures the surface energy of resin after curing.
The contact angle measuring instrument evaluates surface energy by analyzing the contact angle formed by a droplet on a solid surface, based on the principle of Young's equation. Measuring the surface energy of resin after curing is significant for properties such as coating adhesion and bonding.
Contact Angle Meter Evaluates Wettability of Hydrophobic Coatings
A contact angle measuring instrument evaluates the wettability of hydrophobic coatings by analyzing the angle formed by a liquid droplet on a solid surface. Its principle is based on Young's equation, where a contact angle greater than 90° indicates hydrophobicity.
Thermogravimetric Analyzer for Determining the Solid Content of Varnish
The principle of determining the solid content of varnish using a thermogravimetric analyzer is as follows: when the sample is heated, volatile solvents and moisture evaporate, leading to a decrease in mass, while the remaining solid mass stabilizes. The solid content is calculated by comparing the initial and final mass ratios.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
How to Choose the Right Contact Angle Measuring Instrument Based on Sample Characteristics
Contact angle measurement is a key method for evaluating the wettability of solid surfaces and is widely used in fields such as materials science, coating industry, textile testing, electronic packaging, and environmental monitoring.
Porosity Control in the Preparation of Porous Coatings During the Blade Coating Process
Doctor blade coating is a wet coating technique widely used for preparing functional coatings, which involves uniformly applying a slurry containing solid particles (such as ceramics, polymers, or metal oxides) onto a substrate, followed by drying and heat treatment to form the coating.
Contact Angle Meter Selection Guide: How Can Laboratory Beginners Avoid Pitfalls?
The contact angle measuring instrument is used to analyze the wettability of solid surfaces and has applications in various fields such as materials and coatings. When selecting a model as a beginner, it is necessary to first understand key parameters such as static and dynamic contact angles and surface free energy, and then choose the configuration based on the specific application scenario.
Surface Tensiometer vs. Contact Angle Goniometer: Which One to Choose for Wetting Studies?
Surface tension meters primarily measure the surface tension of liquids and are suitable for analyzing the properties of liquids themselves, such as purity or the effects of additives. Contact angle meters, on the other hand, evaluate the wettability of solids by analyzing the contour of liquid droplets on solid surfaces, and are commonly used in surface treatment or coating research.