Wireless Bluetooth Sulfide Ion Meter

The wireless Bluetooth sulfide meter detects the concentration of sulfide ions in a solution through electrodes and uses Bluetooth to transmit data to mobile phones or computers. It is used for water quality monitoring, industrial wastewater analysis, and on-site rapid acquisition of sulfide content.
Selection
When selecting, consider the measurement range to cover requirements, electrode material corrosion resistance, Bluetooth connection stability, device protection rating suitability for the usage environment, ease of operation of the supporting software, and calibration frequency alignment with usage frequency.

Terms

Standards

Instruments

Supports wireless Bluetooth connection to mobile devices, provides 5 Ion concentration Measuring methods, Measurement accuracy +/- 1% F. S, with 2 to 5 point calibrating and manual temperature compensation function to ensure accurate and reliable data.

$ 733.00

Support wireless Bluetooth connection to Android devices, provide 5 point calibrating and 8 calibrating liquid selection, Measurement accuracy of +/- 0.5% F. S, with automatic end point locking and temperature compensation functions to ensure stable and reliable data.

$ 733.00

Support 0.00001~ 1mol/L wide range measurement, accuracy of +/- 0.5% F. S, with 5 point calibrating, ElectRode management and manual temperature compensation functions, can connect Bluetooth devices to achieve Multi-ParaMeter measurement.

$ 733.00

Measurement accuracy of +/- 1% F. S, support 5 point calibrating and manual temperature compensation, with automatic end point locking and limit alarm functions, can be connected to a variety of ion selective ElectRode.

$ 733.00

Measurement accuracy of +/- 1% F. S, 5 point calibrated and a variety of Ion concentration units, ElectRode management and temperature compensation functions ensure stable and reliable measurement.

$ 733.00

Supports 5 Ion concentration Measuring methods, Measurement accuracy of +/- 1% F. S, 2 to 5 point calibrating and manual temperature compensation functions to ensure accurate and reliable measurement data.

$ 733.00

Effective transmission distance of 10 Meters, using Bluetooth wireless transmission technology, equipped with RS-232 software CD, to achieve wireless data communication between measurement equipment and computer.

$ 122.00

Measurement range 0.000005~ 1mol/L, accuracy +/- 0.5% F.S. ElectRode management, temperature compensation and automatic end point locking function ensure stable and reliable measurement.

$ 733.00

Split design, tablet PC control, Bluetooth 4.0 wireless communication, Measurement range Ra 025-12.5 μm, support for a variety of Sensors and auxiliary clamping devices, compact body to adapt to complex working conditions.

$ 1332.00

Support 5 point calibrating and 8 kinds of calibrating liquid, Measurement range 0.00000001~ 0.1mol/L, ElectRode management and manual temperature compensation function to ensure measurement Stability.

$ 733.00

Bluetooth wireless technology supports a transmission distance of about 30.5 Meters, making it easy to set up and download data in hard-to-reach locations. With +/- 0.2 ℃ High Accuracy and weatherproof enclosure, it can work stably in a wide temperature range of -40~ 70 ℃. Data storage capacity is 84650 Measured values.

$ 443.00

Mechatronics design, Bluetooth wireless transmission function, mass storage of 100 sets of data, Measurement range Z axis 160μm, support Ra, Rz and other more than 20 kinds of paraMeter measurement, adapt to -20 ℃~ 40 ℃ working environment.

$ 683.00

Support Bluetooth wireless transmission, can access data through mobile devices within 30 Meters. Built-in self-calibrated CO2 Sensor, Measurement range 0-5000ppm, high accuracy and low maintenance cost. At 5 minutes Sampling rate, the battery can support operation for up to half a year.

$ 975.00

With +/- 0.2 ℃ High Accuracy, Support Bluetooth Wireless Setup and Data Download, Protection Rating up to IP67/NEMA6, Stable operation in harsh outdoor environments of -40~ 70 ℃.

$ 288.00

Supports 5 Ion concentration Measuring methods, providing 2 to 5 point calibrating and 8 concentration calibrating points optional, Measurement range 0.0000001~ 1mol/L, with automatic end point locking and manual temperature compensation function.

$ 733.00

Articles

Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Rubber non-rotor vulcanization tester measures vulcanization curve.
The rubber non-rotor vulcanization tester is used to measure the curve of torque versus time during the vulcanization process, in order to assess the crosslinking degree and vulcanization characteristics of rubber.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Wavelength selection for the determination of sulfate content in water quality using photometric titrator
This article discusses how to select the wavelength when using a photometric titrator to determine the sulfate content in water. The core issue lies in the fact that wavelength selection directly affects the accuracy and anti-interference capability of the detection.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.