Powder Chroma Measurement Instrument

The powder colorimeter measures the color of powders through diffuse reflection spectroscopy. The instrument illuminates the sample with a light source, and the detector receives the reflected light and converts it into chromaticity data. It is used in industries such as coatings and plastics to control the color consistency of powder raw materials and finished products.
Selection
When selecting, consider the matching of powder particle size with the instrument's measurement aperture. Pay attention to the instrument's repeatability index and the inclusion of a specular reflection exclusion function. A sample press is required to ensure the surface of the sample is flat. Check whether it meets the measurement conditions specified by industry standards.

Terms

Standards

Instruments

Special design container to ensure measurement conformity, suitable for color scheme, suitable for fine powder particle measurement, effectively avoid the influence of powder tightness and surface Smoothness.

$ 220.00

Using LED Illuminant to provide stable 470nm wavelength, Measurement range 0-500PCU, accuracy +/- 10PCU, support NIST traceability standard calibrated to ensure the accuracy of water quality chroma detection.

$ 215.00

Constant pressure ensures uniform sampling, suitable for a variety of powder material testing, implementation of GB9087-88 and other standards, improve sampling accuracy and conformity.

$ 222.00

The stainless steel funnel is used to ensure that the surface is smooth and free of static electricity. It is equipped with two specifications of funnel, which are suitable for free-flowing powder and caking trend powder respectively. The receiver volume is 500ml, and the sampling volume is 510-550ml, which meets the standard test requirements.

$ 875.00

Standard funnel method for metal powder flowability measurement, equipped with 2.5mm and 5mm pore diaMeter stainless steel funnel, can accurately measure 50g powder flow time to +/- 0.01s, suitable for powder testing such as cemented carbide.

$ 525.00

Can test flowability, Angle of Peace and Loose Bulk Density, equipped with 30ml stainless steel measuringflask and double powder plate, funnel diaMeter can be selected 5mm or 2.5mm, for precise control of powder mass.

$ 993.00

Four removable baffles are used to break the powder drop, equipped with 1.18mm aperture sieve and 25mL +/- 0.05mL glassgraduates with scale, and the measurement Stability is guaranteed by the vibration-free base, which is suitable for the accurate determination of loose density.

$ 687.00

Measurement principle of scattering-transmitted light, automatic chroma compensation, Measurement range 0~ 200.0NTU, Repeatability +/- 1% F. S, support multi-point calibrating and automatic range switching.

$ 767.00

Equipped with multi-functional test components to measure liquid and powder samples, 8mm measurement caliber to ensure accurate positioning, Repeatability fluctuation is less than 0.07 on average, light positioning function simplifies the operation process.

$ 1655.00

Double pulse Back flushing automatic powder cleaning, Laminating filter accuracy of 0.3 microns, powder gas separation efficiency, stainless steel material is durable, color change operation is simple, improve dust recovery efficiency.

$ 1655.00

With 0.001 NTU resolution and +/- 2% Repeatability, Chroma compensation system eliminates specimen Color interference, and Built-in Printer facilitates real-time data recording.

$ 465.00

The volume weighing method is used to measure the density of free-flowing powder, the diaMeter of the funnel is 60mm, and the volume of the receiver is 500ml. It is suitable for powders with caking trend, and the test process avoids static electricity.

$ 711.00

Using fixed funnel method to measure powder flowability, equipped with 10mm inner through Glass funnel and 0-100mm scale struts, can accurately measure cone height, meet the requirements of Pharmacopoeia and ISO standards.

$ 535.00

Four 25 ° inclined quartz Glass baffles are used to guide the powder flow and are equipped with a 25 +/- 0.05ml standard cylindrical Cup to achieve a loose powder state through natural gravity, ensuring the accuracy and Repeatability of density testing.

$ 687.00

Blue screen LCD module, Built-in Printer convenient data recording, increase the chroma compensation system to avoid Color interference, Measurement range 0-500NTU, resolution up to 0.001, zero drift +/- 1.5%, to ensure long-term stable work.

$ 557.00

Articles

Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Light source configuration and color matching environment requirements in the selection of standard light boxes
This article discusses how to choose a standard light booth, focusing mainly on the light source configuration and observation environment.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Colorimeter controls batch color difference in plastic and rubber films.
This article primarily discusses how to use a colorimeter to control color differences in the production of plastic and rubber films. It explains the working principle of the colorimeter, which involves converting colors into numerical values represented by L, a, and b values, and then calculating the color difference.
Transmittance Meter Selection Guide: Principles for Matching Light Sources and Samples
This article introduces how to select the light source for a transmittance meter based on sample characteristics. The types of light sources include halogen tungsten lamps, LEDs, and lasers, which are suitable for wide-band, monochromatic, or high-precision measurements, respectively.
UV aging test chamber for evaluating the discoloration degree of resin weather resistance
This article introduces the method of using a UV aging test chamber to examine the degree of weather-induced discoloration in resins.
Colorimeter evaluates the change in yellowing index of transparent resin.
This article introduces how to use a colorimeter to measure the yellowing index changes in transparent resin. Transparent resin can turn yellow over time or due to environmental influences, and the yellowing index can quantify the degree of color change.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.