Ammonia Leak Detector

Ammonia leak detectors detect changes in ammonia concentration in the air using electrochemical or semiconductor sensors. When the concentration exceeds the set threshold, they trigger audible and visual alarms. They are used in locations such as cold storage facilities and chemical plants where ammonia refrigerants or raw materials are present, enabling early leakage warnings and safety protection.
Selection
When selecting, consider whether the detection range covers the on-site ammonia concentration, whether the explosion-proof rating matches the environmental characteristics, how the sensor lifespan and calibration cycle affect maintenance costs, whether the output signal is compatible with the existing control system, and whether the enclosure protection rating is suitable for the on-site temperature and humidity conditions.

Terms

Standards

Instruments

Frequency range 20KHz to 100KHz, Sensitivity indicated by LED and sound, weight of only 140 grams for portable, suitable for a variety of gas and air leak detection scenarios.

$ 301.00

Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.

$ 110.00

Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.

$ 1806.00

Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.

$ 209.00

250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.

$ 127.00

Glass-lined, FRP, epoxy coal asphalt coatings of different thicknesses can be mass tested by high voltage detection technology. When the coatings have defects such as pinholing and bubbles, the instrument will emit bright sparks and sound and light alarms.

$ 1230.00

Electrochemical sensor, Response Time ≤ 20 seconds, range 0-100ppm, resolution 0.1ppm, waterproof, dustproof and explosion-proof design, support sound and light vibration triple alarm and Sensor fault self-check function.

$ 202.00

Using 40KHz Frequency and 640KHz crystal time base circuit, the weight is only 50 grams and easy to carry, which can accurately detect air leakage sources in various environments.

$ 157.00

The filling liquid capacity of 30mL, the use of PTFE bottles, Dimension 65mm high × 30mm diaMeter, weight of only 20g, suitable for the maintenance of Ammonia Gas sensing electRode.

$ 135.00

ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.

$ 135.00

Adopting high voltage detection technology, it can sensitively find defects such as coating pinholing and bubbles, equipped with sound and light alarm system, and powered by nickel battery, which is convenient for field operation.

$ 590.00

Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.

$ 164.00

Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds. With Intrinsic Safety (IS) design, support RS485 and 4-20mA dual output, equipped with 2.5 inch color screen display real-time concentration, Temperature Humidity paraMeters.

$ 630.00

Electrochemical sensor for rapid Response, detection accuracy of +/- 2% F. S, with Intrinsic Safety (IS) design and a variety of signal output interfaces, support remote monitoring and data transmission, adapt to -30~ 50 ℃ working environment.

$ 888.00

Using 8-bit microcontroller, Response Time is less than 30 seconds, with IP65 Protection Rating and sound and light vibration alarm function, support 1000 sets of alarm record storage.

$ 235.00

Articles

Differential pressure method gas permeameter measures oxygen transmission rate of films.
This article introduces the method of measuring the oxygen transmission rate of films using the differential pressure gas permeation apparatus.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Effect of Platform Temperature on Surface Drying Time of Waterborne Polyurethane Coatings in Heated Automatic Film Applicators
This study investigates the influence of the platform temperature of a heated automatic film applicator on the surface drying time of waterborne polyurethane coatings. The experiments reveal that as the platform temperature increases, the surface drying time of the coating significantly decreases, showing a negative correlation between the two.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.