Torque and Angle Meter

The torque angle meter is used to measure the torsional angle and torque of rotating components under force, enabling the detection of screw fastening and material torsional strength. It monitors bolt preload in industrial assembly and tests material torsional properties in laboratory settings.
Selection
When selecting, consider the measurement range to cover the torque range of the test object, ensure accuracy matches the process requirements, and verify interface compatibility with existing equipment. Environmental adaptability includes an oil-proof design, and data output functionality should support recording and analysis. Ease of operation and calibration cycle should also be evaluated.

Terms

Standards

Instruments

With +/- 1% accuracy and 0.1 ° angle Graduation, it supports real-time stiffness display and 10 sets of data storage analysis, and the manual loading method is suitable for Φ 100mm rotary diaMeter specimens.

$ 1550.00

Measurement accuracy of +/- 0.1 ° and angle resolution of 0.001 ° with SONY high-speed industrial-grade chip and 0.7-4 zoom Microscope head. Measurement modes such as seat drop method, forward angle and backward angle are supported, and 2 million test records can be stored.

$ 2897.00

Using injection defined bottom surface method for measurement, the funnel outlet has a diaMeter of Φ 5mm and a taper of 60 ° +/- 0.5 °, which can accurately measure the acute angle between the inclined surface of dust accumulation and the horizontal one.

$ 525.00

The injection limited bottom surface method is used to directly measure the angle of repose, the funnel taper is 60 ° +/- 0.5 °, and the outflow diaMeter is 5mm, which is suitable for powder flowability analysis of different particle sizes and shapes.

$ 545.00

Baseline and droplet contours are automatically recognized by machine vision, and contact angles are calculated based on Laplace equation quadratic Linear dispersion fitting. Measurement range is 0-180 °, accuracy is 0.1 °, and dynamic contact angle measurement and surface energy calculation are supported.

$ 3462.00

CCD camera system to achieve 1280 × 1024 resolution image analysis, support 0~ 180 ° contact angle and 0~ 400mN/m surface tension measurement, with dynamic contact angle analysis and solid surface energy estimation function.

$ 4077.00

The static drop method, droplet method and inclined plate method are used for measurement of dynamic contact angle, with automatic sampling, automatic surface tension analysis and automatic contact angle analysis functions. Degree of automation is high and Measurement accuracy is high.

$ 6205.00

Carr Angle of Repose was determined by injection limited bottom surface method, funnel taper 60 ° +/- 0.5 °, outlet diaMeter 5mm can be customized 10mm, easy to operate, durable, can accurately reflect the powder flowability.

$ 493.00

With 20 °/60 °/85 ° three-angle simultaneous measurement, measurement range of 20 ° up to 0-2000Gs, 2.4-inch color screen and 3000mAh lithium battery, support data storage and Bluetooth connection, Stability is high and portable and durable.

$ 554.00

Measurement accuracy of +/- 0.1 °, support for dynamic contact angle analysis, equipped with High Accuracy Optical inspection swirl/spin table and 3 million pixel camera, can handle powder and superhydrophobic materials, database storage 2 million records.

$ 3753.00

Double step motor control titration system, accuracy of 0.01 μl, equipped with 0.7-4 times continuous zoom Microscope and dense LED backlight Illuminant, support dynamic test forward angle, backward angle and surface tension measurement by hanging drop method, test range 0-180 °.

$ 9223.00

Using image analysis method to support high temperature sample testing, camera resolution up to 1280 × 1024, with automatic contact angle calculation and dynamic analysis function, Measurement range 0~ 180 °, accuracy 0.01 °.

$ 3317.00

Optical inspection imagery and image contour analysis technology, Measurement accuracy of +/- 0.1 °, equipped with imported CCD camera and industrial-grade lens, support a variety of droplet state testing and dynamic contact angle fitting.

$ 3268.00

Image analysis method, support high temperature sample testing, camera resolution of 1280 × 1024, with dynamic contact angle analysis and surface energy estimation function, Measurement range 0~ 180 °, accuracy 0.01 °.

$ 2082.00

Sample injector accuracy of 0.01uL, support the surface tension analysis and secondary Linear dispersion fitting contact angle measurement, Measurement range 0-180 ° accuracy 0.1 °, with video recording and dynamic process analysis function.

$ 4269.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Rubber non-rotor vulcanization tester measures vulcanization curve.
The rubber non-rotor vulcanization tester is used to measure the curve of torque versus time during the vulcanization process, in order to assess the crosslinking degree and vulcanization characteristics of rubber.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Rotational Viscometer Measures Viscosity and Processability of Resin Melts
A rotational viscometer calculates viscosity by measuring the torque experienced by a rotor as it rotates in the resin melt, thereby helping to understand the material's processing properties.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Rotational Viscometer for Measuring and Controlling the Application Viscosity of Coatings
A rotational viscometer is a commonly used tool for controlling the viscosity of coatings during application, as it measures the torque generated by a rotor rotating in a fluid to calculate viscosity.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
The cone and plate viscometer measures the rheological properties of a small amount of ink sample.
A cone-plate viscometer measures torque through rotation between the cone and plate, enabling the analysis of rheological properties with small ink samples. It is suitable for small-volume measurements, reducing interference from solvent evaporation.
Method for measuring ink viscosity with a rotational viscometer
A rotational viscometer measures viscosity by detecting the torque experienced by the rotor as it rotates in the ink, with the calculation formula being η = K × (T/ω). Before measurement, it is necessary to select an appropriate rotor, control the temperature, and calibrate the instrument.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
Haze meter detects haze on high-gloss coating surfaces
Haze is the phenomenon where a high-gloss coating surface causes a blurring of reflected images due to light scattering, which reduces visual clarity. A haze meter quantifies the haze value by measuring the intensity ratio between the specularly reflected light and the scattered light at specific small angles. The lower the value, the clearer the surface.
Three-angle gloss meter for evaluating coatings with different gloss levels
Glossiness is a key indicator for evaluating the optical properties of a surface, defined as the ratio of the reflected luminous flux to the incident luminous flux, typically expressed as a percentage or in gloss units.
Method for measuring the gloss of ink surfaces using a gloss meter
This article introduces the method of measuring the surface gloss of ink using a gloss meter. Gloss is a key indicator of the visual quality of ink, and the instrument quantifies gloss by measuring reflected light at specific angles.
The use of a gloss meter in evaluating the surface gloss of printing paper and art paper.
Gloss meters quantify paper gloss by measuring surface reflected light, with 20°, 60°, and 85° angles commonly used for high, medium, and low gloss surfaces, respectively. The gloss characteristics of printing paper and art paper differ, so the appropriate measurement angle should be selected based on the estimated gloss level.