The adhesive force of the tape is 4.3N/cm, and the principle of cross-cut method is adopted, which is suitable for adhesion testing. The performance is stable and non-degumming, and the test results are accurate and reliable.
Equipped with 10-station synchronous test capability, 1000g weight and 1-999999 minute Timer, using SUS #304 steel plate to ensure test accuracy, and automatically recording tape peeling time.
10 station design can carry out multiple sets of tests at the same time. Temperature range RT +~ 250 ℃, hot air circulation to ensure uniform temperature. With over-temperature and electric overload automatic power-off protection, improve operation safety.
Adopt replica tape method to measure surface roughness, Peak Measurement range 20~ 115μm, accuracy +/- 5μm, with automatic subtracting substrate function, High Protection Rating, anti-solvent and water dust.
11/16 inch standard width paper tape, capable of completing approximately 1800 cycles of testing per roll, must be stored at 23 +/- 2 ° C and 50 +/- 10% Humidity to ensure Stability.
Tack is good and non-degumming, adhesion reaches 7.6 N/cm, mass performance is stable, suitable for cross-cut adhesion testing, to ensure accurate film integrity assessment.
Measured value 500N, suitable for tape, PCB, adhesive tape and other materials disbonding force test, supporting the Force Gauge test bench.
Using 2000g +/- 5g roller load and 300mm/min rolling speed to ensure that the adhesive tape sample is flat and evenly adhered to the standard substrate, in line with CNS-11888 and PSTC-8 design standards.
With a 5/10 station design and room temperature range, multiple samples can be tested simultaneously, and the adhesion and durability performance can be accurately evaluated through the suspension weight measurement of the displacement or complete disengagement time.
Complies with ISO 8502-3 standard, can assess the size and size of surface dust, ensure cleaning before lame plating, improve coating adhesion, suitable for passing test and long-term recording.
With 5 groups of independent testing capabilities, the temperature control range is from room temperature to 70 ° C, and the hot air circulation method is used to ensure Temperature uniformity.
Equipped with 1000g weight and 1~ 999999 minute Timer, using SUS #304 steel plate to ensure test accuracy and meet a number of national standards.
Adopting high-temperature non-alkali fiberglass insulation layer sealing resistance wire, the heating area is large and the temperature rises quickly, the maximum operating temperature is 380 ° C and supports continuous work, and the hemispherical design is not easy to bruise Glass ware.
Inlet and outlet devices are used to intRoduce inert gas to effectively prevent oxidation and decarburization of high-temperature heating workpieces. The Furnace volume is 16L and the maximum temperature is 1200 ° C. The high-temperature spraying process of the shell is durable.
Support 10 groups of samples synchronized testing and independent timing, temperature control range from room temperature to 70 ℃, hot air circulation to ensure Temperature uniformity, meet a variety of standard testing requirements.