Using EPA custom Illuminant and chroma compensation technology, Measurement range 0.00-4000 NTU, minimum detection limit < 0.02NTU, support automatic range conversion and multiple calibrate modes to ensure the accuracy of low turbidity measurement.
Simultaneous measurement of turbidity, residual chlorine and total chlorine with EPA custom Illuminant, USEPA 180.1 compliant, automatic range conversion, turbidity Measurement range from 0.00 to 4000 NTU, support for multi-unit display and GLP data management.
With high and low turbidity ranges (0.00-9 and 100-1000NTU) and residual chlorine total chlorine measurement (0.00-5 mg/L), using EPA-specific Illuminant, supporting chroma compensation and Automatic calibration, storing 200 sets of data, suitable for a variety of water quality testing scenarios.
Measurement principle of 90 ° scattered light, Measurement range 0~ 400NTU, resolution 0.01, High Accuracy Optical Path System and Stable Circuit, Support Multi-turbidity Unit switch, with print interface to ensure long-term reliable work.
The principle of scattered light is used for measurement turbidity, the measurement range is 0-200NTU, the resolution is 0.01NTU, the linearity is good and the operation is convenient, and it is suitable for a variety of water quality testing scenarios.
Maxwell turbidity unit measurement of bacterial concentration, resolution 0.001 MCF, range 0-6MCF, with High Accuracy optical path system and low drift circuit, can store 20 records to ensure measurement accuracy and Repeatability.
Using photoelectric detection and automatic dial display, the measurement range is +/- 45 °, the minimum reading is 0.001 °, and the low optical rotation sample can be accurately analyzed, and the operation is simple.
Using photoelectric detection technology to achieve automatic measurement, linear heating rate adjustable eight, Temperature range to 400 ℃, accuracy of +/- 0.5 ℃, in line with pharmacopoeia specifications.
Using photoelectric automatic equilibrating principle, measurement range +/- 45 ° optical rotation and +/- 120 ° Z sugar content, minimum reading +/- 0.001 °, equipped with color LCD Touchscreen and USB interface, support automatic retest 6 times and calculate the average value.
High Accuracy photoelectric induction switch and precision screw drive, the load can be stacked 500/750/1000g, the test angle is 45 °, the operation is accurate and stable, in line with a variety of international standards.
With photoelectric detection and automatic measurement function, Temperature range RT +~ 320 ℃, resolution 0.01 ℃, eight linear heating rate optional, support melting Linear dispersion recording and average calculation.
With photoelectric detection and eight linear heating rate, Temperature range RT +~ 400 ℃, accuracy +/- 0.2 ℃, automatic recording of molten Linear dispersion and calculation of average value, no manual monitoring.
Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 300 ℃, resolution 0.1 ℃, can automatically calculate the average melting point and record the melting Linear dispersion, support three capillary tubing simultaneous measurement.
Using photoelectric automatic detection technology, the temperature resolution reaches 0.1 ℃, the temperature control system applies PID regulation and PWM technology to improve the measurement accuracy and reliability, and supports automatic recording of initial melting and final melting results.
With photoelectric non-contact and contact dual measurement function, Measurement range photoelectric 2.5~ 99999rpm, contact 0.5~ 19999rpm, automatic memory MAX Maximum, MIN Minimum and last value, rugged and portable structure, support USB and Bluetooth data output.