Dissolved Oxygen Probe Pen

A dissolved oxygen meter measures the current generated by the diffusion of oxygen molecules in water through an electrode membrane, converting it into dissolved oxygen concentration. It is used to monitor oxygen levels in water bodies and is commonly applied in aquaculture, wastewater treatment, and environmental monitoring.

Instruments

Using high density polyethylene (PE) oxygen permeable membrane to achieve efficient oxygen diffusion, equipped with ABS plastic screw cap structure for easy installation and electrolysis filling, and interact with the current system for accurate measurement of dissolved oxygen concentration.

$ 243.00

The use of PTFE oxygen permeable membrane to ensure oxygen permeability, spiral cap design for easy installation and electrolysis filling, suitable for Portable dissolved oxygen measurement equipment maintenance.

$ 243.00

PTFE oxygen permeable membrane ensures oxygen permeability, ABS plastic material enhances durability, screw cap design simplifies installation process, suitable for long-term water quality monitoring applications.

$ 243.00

Equipped with polarographic dissolved Oxygen electRode, Measurement accuracy +/- 0.5mg/L, support automatic temperature compensation and manual salinity compensation, full waterproof design to ensure harsh environment use, built-in a number of custom paraMeter settings.

$ 361.00

Sterling silver cathode and zinc anode construction, integrated temperature sensor for instant measurement without conditioning time, thin permeable membrane isolates Sensor and allows oxygen to pass, generating current to determine oxygen concentration.

$ 162.00

Using PTFE oxygen permeable membrane, the probe cathode and anode are isolated from the sample, and oxygen passes through the membrane and acts with the polarographic system to generate current to ensure accurate and reliable measurement.

$ 299.00

Optical inspection dissolved oxygen Sensor technology, strong and durable, measurement depth of 100 Meters, accuracy of +/- 0.2mg/L (8mg/L). Probe removable replacement, easy maintenance, suitable for long-term underwater monitoring.

$ 2387.00

Measurement range of 50ppm dissolved oxygen and 600% Saturation, support pressure, temperature and salinity automatic compensation, can be used continuously for about 200 hours, with IP67 waterproof rating.

$ 1409.00

Optical inspection fluorescence technology for measurement of dissolved oxygen, no polarization time, fast Response and not affected by Flow velocity; Built-in temperature sensor, Measurement range 0.00-50 mg/L, accuracy up to 1.5% +/- 0.01mg/L; Protection Rating IP68, suitable for harsh environments.

$ 3401.00

Polarography design, equipped with PTFE membrane can be quickly replaced, integrated temperature sensor to achieve temperature compensation, suitable for BOD testing, long probe shaft can be directly loaded into the BOD bottle for 5-day latency measurement.

$ 996.00

Polarography dissolved oxygen Measurement range 0.00~ 50.00mg/L, Response Time ≤ 45s, support automatic temperature compensation and salinity compensation, with IP65 Protection Rating, Data storage 500 sets and GLP standards.

$ 674.00

Polarographic probe accurate to 0.3ppm, equipped with 4 Meters of cable to facilitate measurement of hard-to-reach areas; automatic temperature compensation range 0.0-50 ℃, support salinity and height compensation to ensure on-site data Reliability.

$ 1027.00

An ultra-thin 12mm diaMeter design for easy measurement in narrow containers, built-in thermistor temperature sensor compensates for 0 to 50 ° C variations, PEI body material and PTFE oxygen permeable membrane for increased durability and maintenance efficiency.

$ 987.00

With pH, ORP, dissolved oxygen three measurement functions, support automatic temperature compensation and salinity compensation, built-in 500 data storage, equipped with USB Communication interface, Measurement accuracy of +/- 0.002pH.

$ 630.00

Polarographic coating ElectRode, Response Time no more than 30 seconds, automatic temperature compensation range 0~ 40 ℃, portable design for easy field operation, Measurement range 0.0~ 20.0mg/L, accuracy +/- 0.3mg/L.

$ 175.00

Articles

Dyne Pen Selection, Surface Energy Test Range, and Pen Tip Lifespan
The dyne pen is used to evaluate the wettability of material surfaces, reflecting the effectiveness of treatments by measuring surface energy.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Pencil Hardness Plan Outstanding Paint Film Pencil Hardness Grade
The pencil hardness test is a method for evaluating the scratch resistance of paint films. It involves using a series of pencils with known hardness levels to scratch the coated surface under fixed conditions. The hardness grade of the coating is determined by observing whether permanent scratches are produced.
Application of Film Pencil Hardness Tester in Coating Scratch Resistance Testing
The paint film pencil hardness tester is an instrument used to evaluate the scratch resistance of coatings. It works by scratching the surface of the coating with a pencil of known hardness under a fixed load, and then assessing the hardness grade based on whether scratches are produced.
Classification standards for determining the hardness of coatings using a pencil hardness tester.
This article introduces the method of measuring the hardness of coatings using a pencil hardness tester. It involves using pencils of varying hardness to scratch the coating and observing whether scratches are produced to determine the hardness grade, ranging from 6B to 9H.
Key Operational Points and Influencing Factors of Pencil Hardness Method for Determining Coating Film Hardness
The pencil hardness test is a method used to evaluate the scratch resistance of a coating by making marks on the paint film with pencils of known hardness. During the operation, a uniformly cured sample is prepared, and calibrated pencils are used to make marks at a 45-degree angle with a fixed force, aiming to identify the highest hardness grade that does not scratch through the paint film.
How to Select a Pencil Hardness Tester? A Comprehensive Guide from Principles to Practical Application
When selecting a pencil hardness tester, focus on three key points: choose manual or automatic based on standards, use specialized testing pencils, and ensure the instrument can fix a 45-degree angle for uniform force application to achieve accurate and reliable results.