Plated Layer Cup Bulge Test Instrument

The coating cupping tester uses a punch to uniformly press against the sample, causing the coating to deform along with the substrate until cracking occurs. It measures the indentation depth or observes crack morphology to evaluate the coating's ductility, adhesion, and crack resistance. It is suitable for quality control of materials such as metal sheets and paint films.
Selection
When selecting, consider matching the punch speed and diameter with the testing standards. The specimen thickness determines the maximum stroke, and the material type corresponds to the range of cup bulge dimensions. Calibration of the blank holder force is necessary to prevent slipping. For daily testing, choose a basic model, while for research and development, opt for a model with enhanced data recording capabilities.
Control mode

Terms

Standards

Instruments

Using 4mm flow hole and chrome-plated Cup structure, the outflow time range is 0-150 seconds, and the correction factor K = 1 +/- 0.03 ensures accurate and reliable viscosity measurement.

$ 115.00

Replaceable 1-8mm aperture stainless steel filter, Cup mouth annular groove design to store overflow liquid, Cup body made of titanium anodic oxidation aluminum, outflow hole diaMeter 6mm, easy to clean and equipped with a unique serial number.

$ 420.00

1-8Mm pore diaMeter stainless steel filter can be replaced to meet different viscosity range tests; Cup mouth annular groove design can store overflowing liquid; Cup body is made of titanium anodic oxidation aluminum material, durable and easy to clean.

$ 422.00

Adopt replaceable filter design, support 1-8mm aperture selection; Cup annular groove can store overflowing liquid, Cup wall has no clean dead angle; comply with DIN53211 standard, with unique serial number for easy tracking.

$ 441.00

The 1mm-8mm pore size filter can be replaced to meet the viscosity range test of 96~ 683cSt; the annular groove of the Cup mouth is designed to store overflowing liquids, and the Cup body is easy to clean without sinkage. It is equipped with a stainless steel filter positioner.

$ 403.00

Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Made of titanium anodic oxidation aluminum, the flow hole diaMeter is 6mm, the Cup height is 75mm, and each Cup is engraved with an independent serial number to ensure Measurement accuracy and durability.

$ 438.00

6Mm flow hole design, measurement viscosity range 188~ 684cSt, aluminum alloy Cup with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

Outflow diaMeter of 4.1mm, measurement viscosity range of 70~ 370cst, flow time of 30~ 100s, the Cup body is made of titanium anodic oxidation aluminum material, filter and handle are stainless steel, the structure is sturdy and durable.

$ 497.00

It adopts aluminum alloy Cup body and stainless steel outflow nozzle structure, the outflow aperture is 6mm, and the outflow time of Newton-type liquid in the viscosity range of 188~ 684cSt can be measured, which meets the test requirements of international standards.

$ 146.00

Using 5mm flow hole design, the measurement viscosity range of 91~ 326cSt, aluminum alloy Cup body with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

Conform to DIN 53211 standard, evaluate viscosity by measuring 100ml liquid outflow time, 4mm pore size design is suitable for 112~ 685cSt viscosity range, outflow time is 25~ 150 seconds, anodic oxidation aluminum alloy Cup body corrosion resistance.

$ 130.00

Portable design with long stainless steel handle for easy operation. Outflow aperture 5.8mm, can measure 200-1200cSt viscosity range, corresponding to outflow time 30-100 seconds. Cup body aluminum alloy with stainless steel nozzle, both lightweight and corrosion resistance.

$ 285.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, aperture 1.90mm, viscosity measurement range of 10~ 35cSt, flow time of 55~ 100 seconds, suitable for liquid viscosity evaluation.

$ 130.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the diaMeter of the flow hole is 2.53mm, the viscosity range is 25~ 120cSt, and the liquid viscosity is evaluated by measuring the outflow time, which conforms to the ASTM standard design.

$ 130.00

Articles

Taber Abrasion Test Method for Wear Resistance of Coating Films
This article introduces the Taber abrasion test method, which is used to evaluate the ability of coatings, such as those on floors, furniture, or car interiors, to resist mechanical wear.
The effect of the substrate fixing method on coating uniformity in a vacuum adsorption blade coating tester.
This article discusses the impact of different substrate fixing methods on coating uniformity in a vacuum-assisted knife-over-roll coating tester. It compares four methods—vacuum adsorption, electrostatic adsorption, mechanical clamping, and adhesive fixing—focusing on their mechanical principles and limitations.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
Flexibility of Elastic Coatings Tested by Cylindrical Mandrel Bend Tester
This article introduces a method for testing the flexibility of elastic coatings using a cylindrical mandrel bending tester. During the test, the coated test panel is bent around cylindrical mandrels of varying diameters to 180 degrees to observe whether the coating cracks or peels off.
Pencil hardness tester rapidly evaluates scratch resistance of paint film.
This article introduces how to quickly assess the scratch resistance of paint films using a pencil hardness tester. During the test, standard pencils (ranging from 6B to 9H) are used to scratch the coating at a fixed angle and pressure to observe whether scratches occur.
Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Application of Automatic Film Coating Machine in Waterproof Coating Finishing of Textiles
Automatic film coating machines are used for waterproof coating finishing on textiles, enabling precise control of coating thickness, improving uniformity and production efficiency.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
Application of Laboratory Coating Machines in the Coating of Optical-Grade PET Anti-Reflection Coatings
This article discusses the application of laboratory coating machines in the preparation of anti-reflective coatings on optical-grade PET substrates. By controlling parameters such as coating speed and gap, the coating machine enables precise adjustment of coating thickness, thereby enhancing light transmittance and reducing reflection.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium Battery Separators
This article introduces the application of automatic coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional