Impact energy 2.7mJ, Impact device mass 75g, small damage to the measured surface, does not damage the hardened layer, suitable for measurement of small and thin parts, the minimum thickness of the specimen is 1mm, and the minimum depth of the hardened layer is 0.2mm.
Impact energy 3N, Impact device mass 75g, suitable for measurement of small or thin specimens and surface hardening layer, the minimum thickness can be measured 1mm and the minimum hardening layer depth 0.2mm.
Frequency 10MHz, Measurement range 0.65~ 20mm, suitable for thin-walled and small curved surface workpieces, the lower limit of pipe measurement Φ 10 * 1.0mm.
Frequency 7MHz, Probe diaMeter 6mm, can be measured thin-walled and small arc surface, minimum pipe diaMeter Φ 15mm, Measurement range 0.75-80 mm, suitable for different environmental conditions.
Impact energy is only 2.7mJ, minimal damage to the measured surface, does not damage the hardened layer, suitable for testing 1mm thickness of small parts, Cedar diaMeter minimum 0.32mm.
Using 7.5MHz High Frequency Probe, Measurement range 0.7~ 50mm, suitable for thin-walled and small arc surface workpieces, the lower limit of pipe measurement is Φ 25 * 1.2mm, strong adaptability.
Measurement range 0.0~ 500μm, error +/- (0.3μm + 2%), ultra-small probe suitable for nails, bolts and other small workpiece thin platings measurement, with multi-point calibrating and statistical functions to ensure high Repeatability and Stability.
The equipment adopts High Accuracy modular Spreader station, Spreader thickness range 0.01mm~ 2mm, coating speed 2~ 4.5m/min adjustable, with UV instant curing and heating function, suitable for a variety of materials such as paper, film and so on.
Using extrusion process and chrome plating surface, the wet film thickness can be as low as 1.5 μ m, and the groove design is wide to improve the Coating Weight, which solves the problem of traditional steel wire loosening and cleaning difficulties, and realizes stable ultra-thin Spreader.
The wet film thickness can be as low as 1.5μm to achieve ultra-thin Spreader; the bottom of the groove is wider, and the Coating Weight is larger; the extrusion process is adopted to avoid the problem of loose wire and broken wire, and it is easy to clean.
Travel 0-1.25 mm, measurement error +/- 1HAM, suitable for thin rubber samples with a thickness of 1.5mm or more. Sensitivity is high, and it needs to be used with a constant load measuring rack to ensure Precision.
Spreader accuracy +/- 0.003mm, Spreader thickness range 0.001~ 10mm adjustable, with Vacuum chuck and heating function, support bar and drawdown blade two coating methods to ensure Spreader uniformity and repRoducibility.
Adopt High Accuracy modular Spreader station structure, all-electric control without external air source. The minimum thickness of Spreader can reach 0.01mm, the maximum Spreader width is 300mm, the Spreader speed is adjustable 2-4.5 m/min, and it has an electronically controlled precision tension system to adapt to different materials such as paper and plastic film.
Adopt High Accuracy modular Spreader station structure, all-electric control without external air source; Spreader thickness can reach a minimum of 0.01mm, accuracy +/- 0.003mm; equipped with UV LED curing module, instant curing; Spreader width 400mm, speed 2-4.5 m/min adjustable, forward and reverse stepless transmission.
Echo-echo technology implementation of 0.15mm ultra-thin part measurement, resolution of 0.001mm, can penetrate 0.5mm coating measurement substrate Film thickness, support sound speed calibrated and difference mode settings.