250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.
Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.
Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.
Colorimetric measurement based on Nasler method, Measurement range 0.00-10 mg/L, providing 100 tests, accurate determination of ammonia nitrogen concentration by Color intensity change.
Colorimetric measurement using Nessler method. Measurement range is 0.0~ 100.0 ppm ammonium. 100 tests are provided. Yellow shade is generated for concentration determination.
Colorimetric measurements using the Nessler method are fast. Measurement range is 0.0 to 100.0 mg/L, providing 300 tests, ensuring accurate determination of ammonium Ion concentration and supporting unit conversion.
Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.
Measurement range 0.00~ 9.99 ppm, accuracy +/- 0.05 ppm, LED Illuminant 470 nm, automatic shutdown function, compact and portable design.
Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.
Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds. With Intrinsic Safety (IS) design, support RS485 and 4-20mA dual output, equipped with 2.5 inch color screen display real-time concentration, Temperature Humidity paraMeters.
The filling liquid capacity of 30mL, the use of PTFE bottles, Dimension 65mm high × 30mm diaMeter, weight of only 20g, suitable for the maintenance of Ammonia Gas sensing electRode.
Optical inspection system using imported cold Illuminant and narrow band interference, Optical inspection stability is less than 0.002A/20min, digestion temperature accuracy +/- 0.5 ℃, support COD and ammonia nitrogen dual paraMeter measurement, can save multiple standard Linear dispersion and data.
ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.
Using pump-suction sampling and imported Electrochemical sensor, Response Time ≤ 20 seconds, detection accuracy ≤ +/- 3%, support 1-4 Sensor expansion, Protection Rating IP65 for harsh environments.
ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, copper ion type, capacity 480 ml, to ensure ElectRode performance stability and measurement accuracy.