Industrial halogen gas Detector

Industrial halogen gas detectors measure the concentration of halogen gases in the air through sensors, converting the gas concentration into electrical signals using electrochemical or semiconductor principles. They are used to monitor leaks of halogen gases such as fluorine and chlorine in production environments to ensure operational safety. These detectors are commonly employed in industries such as chemical and electronics for gas leak detection and emission monitoring.
Selection
When selecting, consider the matching of the gas types and measurement ranges with on-site requirements. The sensor type should be suitable for the environmental temperature and humidity, with a short response time for rapid early warning. The protection rating must meet the explosion-proof requirements of the installation area. Data recording functionality should fulfill regulatory needs, and maintenance cycles and calibration convenience will impact usage costs.

Terms

Standards

Instruments

It can detect halogen gas leaks of less than 0.5 ounces per year, with an instantaneous Response Time and a Warm-Up Time of less than 90 seconds. It features automatic warm-up and battery protection, and a portable design weighing only 480 grams.

$ 154.00

Semiconductor Sensor to detect halogen gas leaks of less than 0.5 oz/year, Response Time ≤ 1 second, Sensitivity adjustable, Portable design weighing 250g, up to 9 hours of operation.

$ 109.00

Instantaneous Response Time Less than 6 seconds warm-up, can detect 3 g/year Sensitivity halogen refrigerant, 405 g lightweight design with 5 hours continuous Working time, with automatic warm-up and two-color LED charge indication function.

$ 140.00

Using Industrial Sensor, Response Time T90 is less than 60 seconds, with waterproof, dustproof and explosion-proof function, round and durable shell, suitable for Gas detection in various industrial environments.

$ 248.00

Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, with explosion-proof structure, support 4-20mA and RS485 output, suitable for a variety of Gas detection.

$ 251.00

With explosion-proof structure design, Response Time is less than 30 seconds, resolution is up to 0.1ppm, with 4-20mA and RS485 signal output, suitable for gas monitoring needs of various industrial environments.

$ 251.00

Electrochemical sensor, Response Time less than 30 seconds, Measurement range 0-100ppm, 4-20mA signal output and explosion-proof structure, suitable for gas monitoring in harsh industrial environments.

$ 267.00

Using industrial grade Sensor to detect nitrogen dioxide gas, range 0~ 20ppm, resolution 0.1ppm, Response Time T90 < 60s, with waterproof, dustproof and explosion-proof characteristics, small and durable.

$ 248.00

Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, with explosion-proof structure, support 4-20mA and RS485 output, suitable for a variety of Gas detection.

$ 193.00

Using Industrial Sensor, Response Time is less than 30 seconds, accuracy +/- 3% FS, with explosion-proof structure and multi-Gas detection ability, to ensure stable and reliable gas concentration monitoring.

$ 251.00

Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, with explosion-proof structure and 4-20mA standard signal output, suitable for a variety of Gas detection needs.

$ 267.00

Explosion-proof structure design, Response Time is less than 30 seconds, with 4-20mA standard signal output, can detect a variety of gas concentrations and set high and low alarm points to ensure industrial environment safety monitoring.

$ 267.00

Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.

$ 314.00

Using Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, shell explosion-proof structure, 4-20mA standard signal output, can detect a variety of gas concentrations and have sound and light alarm function.

$ 267.00

Detect NH3 gas, range 0~ 100ppm, resolution 0.1ppm, Response Time T90 ≤ 120s, support sound and light alarm, Operating temperature -10~ 50 ℃, Working time for more than 60 hours, Portable design weighs only 170 grams.

$ 328.00

Articles

Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Differential pressure method gas permeameter measures oxygen transmission rate of films.
This article introduces the method of measuring the oxygen transmission rate of films using the differential pressure gas permeation apparatus.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.