Digital AnemoMeter

The digital anemometer converts airflow speed into electrical signals through thermal or vane sensors, with the digital screen directly displaying the wind speed value. It is used to measure wind speed data in ventilation systems and environmental monitoring, and to inspect airflow conditions in laboratories and industrial sites.
Selection
When selecting, confirm the measurement range and accuracy, and consider portability or fixed installation needs based on the application environment. Pay attention to whether the sensor type matches the detection medium, check the instrument's protection rating and calibration certificate, and ensure the operation interface is clear and easy to read.
Wind speed range
Wind speed error
Air temperature range
Air volume measurement

Terms

Standards

Instruments

With 0.3~ 45m/s wide range wind speed measurement and 0~ 45 ℃ wind temperature detection capabilities, support multi-unit switching and maximum MIN Minimum recording, equipped with backlight display and low power prompt function, resolution of 0.001m/s.

$ 100.00

Measurement range 0.3~ 30m/s, accuracy +/- 5% +/- 0.1dgt, can simultaneously measure air temperature 0~ 50 ℃, with maximum MIN Minimum recording function, suitable for a variety of environment monitoring needs.

$ 89.00

Measurement range 0.3~ 45m/s, accuracy +/- 3% +/- 0.1dgt, support air volume and air temperature measurement, with data storage and backlight display functions, suitable for a variety of environment monitoring needs.

$ 124.00

Simultaneous measurement of wind speed, wind temperature, wave height and air volume, equipped with 24 sets of data storage functions, sampling rate of about 1 second, low friction bearing impeller Sensor to ensure measurement accuracy.

$ 198.00

Adopt low friction bearing impeller Sensor, support wind speed, wind temperature, wave height, wind level and air volume measurement, with 24 data storage and 0-9 minutes adjustable automatic shutdown function, Sampling rate about 1 second.

$ 172.00

It can simultaneously measure 6 paraMeters such as wind speed, wind temperature and wind direction, equipped with 24 sets of Data storage functions, adopts ultra-low friction bearings to ensure High Accuracy measurement, and supports USB and Bluetooth data transmission methods.

$ 315.00

Simultaneous measurement of wind speed, wind temperature, wave height, wind level and air volume, equipped with low friction bearing impeller Sensor to ensure +/- 2% accuracy, support 24 data storage and USB/Bluetooth communication methods.

$ 186.00

Measurement unit conversion function, support 24 data storage, Ultra low friction bearing Sensor to ensure high Sensitivity and accurate measurement, wind speed measurement handle can be separated from the fuselage for easy operation.

$ 243.00

Using microcomputer intelligent PID digital display temperature control, temperature control accuracy +/- 1 ℃, equipped with hot air circulation system to ensure uniform temperature, indoor shelf height and quantity adjustable, easy access to different specifications of samples.

$ 288.00

Quadruple Synchronous Stir Design, Temperature range RT +~ 100 ℃, using digital electronic temperature control technology, heating power 150W * 2, stirring speed 0~ 2000rpm, DC motor running without noise vibration.

$ 243.00

Using digital temperature control technology, Temperature range RT +~ 100 ℃, Tank size 300 * 300mm, combined design operation is more convenient, suitable for long-term stable operation.

$ 277.00

Adopting 25 * 25mm square design, the center digital display window shows white characters on a black background after overheating, the frame has regression directional reflection technology, can be identified from a distance in low light environment, waterproof and stain-resistant and with anti-fouling protective film.

$ 89.00

Six-station synchronous operation, Max. stirring Capacity 1000mL × 6, Speed range 50~ 1700rpm, LED digital tube real-time display Rotation speed paraMeters, support Continuous Operating Mode.

$ 517.00

Using refraction principle design, LCD large-screen liquid crystal digital display, quick display results within 3 seconds, automatic temperature compensation function, more than 10,000 times of use, with automatic shutdown and power alarm function.

$ 251.00

Equipped with a digital ruler to collect displacement data, the resolution is up to 0.01mm, the maximum measurement load is 500N, the base has a mobile platform for easy installation of fixtures, and the side handwheel is easy to load and operate.

$ 357.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
Application of Drop Hammer Impact Testing Machine in Evaluating Impact Resistance of Composite Materials
This article introduces how the drop-weight impact testing machine evaluates the impact resistance of composite materials. The test releases a weight to strike the specimen, measuring parameters such as energy absorption, peak load, and damage area, simulating low-velocity impacts like tool drops.
Impact of the Fixture Design of a Drop Hammer Impact Tester on the Plastic Impact Strength Results
This article primarily discusses the impact of the fixture design of a drop-weight impact testing machine on the results of plastic impact strength tests. The geometric parameters of the fixture, clamping method, and contact surface material can alter the stress state and energy transfer of the specimen, thereby affecting the accuracy of the test data.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Shore Durometer Selection: Matching Principles of Hardness Models and Measurement Ranges
This article introduces the selection method for Shore durometers, with the core focus on ensuring that the hardness type matches the material's hardness range and rebound characteristics. When selecting, the principle that the measured value falls within 20% to 80% of the full scale should be followed to avoid data distortion.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Optimization of mixing efficiency of vortex mixer in liquid-liquid microextraction
This paper explores how to enhance mixing efficiency in liquid-liquid microextraction by adjusting the operating parameters of a vortex mixer.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.