Dissolved Oxygen in Water

Dissolved oxygen in water refers to the content of free oxygen in the water body. It is measured by electrode or chemical methods to determine the amount of oxygen molecules dissolved in the water. It is used for monitoring water quality, assessing the self-purification capacity of water bodies, and evaluating the living conditions of aquatic organisms. It is commonly applied in environmental monitoring, aquaculture, and wastewater treatment processes.
Selection
When selecting a dissolved oxygen meter, it is essential to consider a measurement range that covers actual needs, accuracy that meets testing standards, and probe types suitable for the field environment. Pay attention to the instrument's calibration method, temperature compensation function, and protection rating to ensure data reliability and equipment durability.

Terms

Standards

Instruments

Using high density polyethylene (PE) oxygen permeable membrane to achieve efficient oxygen diffusion, equipped with ABS plastic screw cap structure for easy installation and electrolysis filling, and interact with the current system for accurate measurement of dissolved oxygen concentration.

$ 243.00

With pH, ORP, dissolved oxygen three measurement functions, support automatic temperature compensation and salinity compensation, built-in 500 data storage, equipped with USB Communication interface, Measurement accuracy of +/- 0.002pH.

$ 630.00

Measurement range of 50ppm dissolved oxygen and 600% Saturation, support pressure, temperature and salinity automatic compensation, can be used continuously for about 200 hours, with IP67 waterproof rating.

$ 1409.00

Can simultaneously measure pH, dissolved oxygen and temperature paraMeters, support automatic temperature compensation and ElectRode diagnosis, data storage capacity of 450 groups, with statistical analysis and Bluetooth printing function, dustproof and waterproof grade IP54.

$ 812.00

Optical inspection fluorescence technology for measurement of dissolved oxygen, no polarization time, fast Response and not affected by Flow velocity; Built-in temperature sensor, Measurement range 0.00-50 mg/L, accuracy up to 1.5% +/- 0.01mg/L; Protection Rating IP68, suitable for harsh environments.

$ 3401.00

The use of PTFE oxygen permeable membrane to ensure oxygen permeability, spiral cap design for easy installation and electrolysis filling, suitable for Portable dissolved oxygen measurement equipment maintenance.

$ 243.00

Polarography dissolved oxygen Measurement range 0.00~ 50.00mg/L, Response Time ≤ 45s, support automatic temperature compensation and salinity compensation, with IP65 Protection Rating, Data storage 500 sets and GLP standards.

$ 674.00

With conductivity 0-2000mS/cm and dissolved oxygen 0-20mg/L wide range measurement, support automatic temperature compensation and air pressure compensation, 3.5 inch color screen display, data storage capacity of 3000 groups, Protection Rating is IP57.

$ 670.00

PTFE oxygen permeable membrane ensures oxygen permeability, ABS plastic material enhances durability, screw cap design simplifies installation process, suitable for long-term water quality monitoring applications.

$ 243.00

Support conductivity 0-200mS/cm and dissolved oxygen 0-20mg/L measurement, with automatic temperature compensation, ElectRode diagnostic function and IP54 Protection Rating, Data storage up to 450 groups and support Bluetooth printout.

$ 841.00

Equipped with polarographic dissolved Oxygen electRode, Measurement accuracy +/- 0.5mg/L, support automatic temperature compensation and manual salinity compensation, full waterproof design to ensure harsh environment use, built-in a number of custom paraMeter settings.

$ 361.00

Built-in three measurement units can simultaneously detect pH, Conductivity Detector and dissolved oxygen, support automatic temperature compensation and ElectRode diagnosis, with IP54 Protection Rating, data storage capacity of 500 groups, support GLP specification to achieve data traceability.

$ 1142.00

Using PTFE oxygen permeable membrane, the probe cathode and anode are isolated from the sample, and oxygen passes through the membrane and acts with the polarographic system to generate current to ensure accurate and reliable measurement.

$ 299.00

Equipped with 7-inch color Touchscreen, support 5 ElectRode management and 1000 data storage, with three reading modes and automatic temperature and pressure compensation function, dissolved oxygen Measurement range 0-90mg/L, accuracy +/- 0.10mg/L.

$ 2045.00

With pH, ORP and dissolved oxygen three measurement functions, support 1-5 point calibrating and automatic ElectRode diagnosis, can store 500 sets of data and have USB Communication interface, Measurement accuracy of +/- 0.002pH and +/- 0.2mg/L.

$ 593.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Application of Automatic Film Coating Machine in Waterproof Coating Finishing of Textiles
Automatic film coating machines are used for waterproof coating finishing on textiles, enabling precise control of coating thickness, improving uniformity and production efficiency.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.