Sulfur Dioxide Gas Leak Detector

The sulfur dioxide gas leak detector measures changes in gas concentration using an electrochemical sensor. When sulfur dioxide comes into contact with the sensor, it generates an electrical current signal, which is processed by the circuit to display the leakage value. It is used to monitor sulfur dioxide leaks in pipelines and containers, ensuring operational safety.
Selection
When selecting, consider whether the detection range covers the application requirements, as sensor lifespan and calibration cycles affect the cost of use. Ensure the protection rating is suitable for environmental conditions, and the response time guarantees quick leak detection. Data logging functionality facilitates tracking and analysis.

Terms

Standards

Instruments

Designed with flameproof and explosion-proof structure, Response Time is less than 30 seconds, accuracy +/- 3% FS, can detect 0-20ppm sulfur dioxide concentration, support 4-20mA and RS485 signal output, suitable for harsh industrial environments.

$ 251.00

Frequency range 20KHz to 100KHz, Sensitivity indicated by LED and sound, weight of only 140 grams for portable, suitable for a variety of gas and air leak detection scenarios.

$ 301.00

8Mm thick PVC reinforced rigid plastic plate box, sulfur dioxide concentration adjustment range of 600~ 10000ppm, equipped with corrosion-resistant silicone airway and alkali solution exhaust gas treatment system, temperature control accuracy +/- 0.5 ℃.

$ 15823.00

Using electrochemistry principle to detect 0-100ppm sulfur dioxide, with 4G/WIFI wireless communication, IP66 Protection Rating, four Alarm modes and 12-55 hours battery life, support remote paraMeter configuration and temperature compensation algorithm.

$ 588.00

Electrochemical sensor, sulfur dioxide detection range 0-20ppm, resolution 0.1ppm, with IP65 Protection Rating and 12864 point matrix display, support sound, light, vibration triple Alarm mode.

$ 235.00

Support 4 kinds of gas simultaneous detection, integrated temperature Humidity monitoring, physical + software double revisit Humidity compensation, with zero automatic correction function, Response Time T90 ≤ national standard, detection accuracy ≤ +/- 3% FS.

$ 1050.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, with explosion-proof structure and a variety of signal output interfaces, support remote monitoring and alarm functions.

$ 719.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds. With flameproof structure, it supports 4-20mA, RS485 and switch output, and can be linked to fan and other control equipment.

$ 267.00

Using industrial-grade Sensor and micro-control technology, Response Time T90 is less than 60 seconds, with waterproof, dustproof and explosion-proof characteristics, round and durable shell, continuous use of not less than 8 hours.

$ 248.00

Simultaneously detect 4 kinds of gases and integrate temperature and Humidity detection, adopt dual temperature Humidity compensation design, Response Time T90 ≤ national standard, with a variety of wireless communication options and remote paraMeter configuration functions.

$ 635.00

Using industrial grade Sensor to detect nitrogen dioxide gas, range 0~ 20ppm, resolution 0.1ppm, Response Time T90 < 60s, with waterproof, dustproof and explosion-proof characteristics, small and durable.

$ 248.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring functions.

$ 528.00

Support simultaneous detection of 4 kinds of gases, integrated temperature Humidity detection function, physical + software double revisit Humidity compensation, Response Time T90 ≤ national standard, detection accuracy ≤ +/- 3% FS, with a variety of alarm and remote monitoring capabilities.

$ 658.00

Adopt 8mm thickness PVC reinforced rigid plastic plate shell, sulfur dioxide concentration 10~ 30ppm adjustable, equipped with corrosion-resistant silicone airway and alkali solution exhaust gas treatment system, Temperature Uniformity ≤ +/- 2 ℃.

$ 15581.00

Pump suction sampling, Response Time T90 ≤ 20s, detection accuracy ≤ +/- 3%, built-in 4000mAh battery, can store 120000 sets of data, with Temperature Humidity detection function.

$ 469.00

Articles

Differential pressure method gas permeameter measures oxygen transmission rate of films.
This article introduces the method of measuring the oxygen transmission rate of films using the differential pressure gas permeation apparatus.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.