Permeable Dissolved Oxygen Analyzer

The permeation dissolved oxygen analyzer isolates the sample through a permeable membrane, allowing oxygen molecules to diffuse into the electrolyte and undergo a reduction reaction, generating an electric current. The magnitude of the current is proportional to the oxygen concentration. It is used to monitor the dissolved oxygen content in liquid environments such as water bodies and fermentation broths, and to track oxygen changes in applications like wastewater treatment and aquaculture.
Selection
When selecting, consider that the measurement range covers actual needs, the response time matches the process speed, and the membrane material's corrosion resistance is compatible with the medium. The calibration method should be simple and stable, the probe structure should suit the installation environment, and the output signal should match the existing system.

Terms

Standards

Instruments

Using PTFE oxygen permeable membrane, the probe cathode and anode are isolated from the sample, and oxygen passes through the membrane and acts with the polarographic system to generate current to ensure accurate and reliable measurement.

$ 299.00

Using high density polyethylene (PE) oxygen permeable membrane to achieve efficient oxygen diffusion, equipped with ABS plastic screw cap structure for easy installation and electrolysis filling, and interact with the current system for accurate measurement of dissolved oxygen concentration.

$ 243.00

The use of PTFE oxygen permeable membrane to ensure oxygen permeability, spiral cap design for easy installation and electrolysis filling, suitable for Portable dissolved oxygen measurement equipment maintenance.

$ 243.00

PTFE oxygen permeable membrane ensures oxygen permeability, ABS plastic material enhances durability, screw cap design simplifies installation process, suitable for long-term water quality monitoring applications.

$ 243.00

Sterling silver cathode and zinc anode construction, integrated temperature sensor for instant measurement without conditioning time, thin permeable membrane isolates Sensor and allows oxygen to pass, generating current to determine oxygen concentration.

$ 162.00

Measurement range of 50ppm dissolved oxygen and 600% Saturation, support pressure, temperature and salinity automatic compensation, can be used continuously for about 200 hours, with IP67 waterproof rating.

$ 1409.00

Optical inspection fluorescence technology for measurement of dissolved oxygen, no polarization time, fast Response and not affected by Flow velocity; Built-in temperature sensor, Measurement range 0.00-50 mg/L, accuracy up to 1.5% +/- 0.01mg/L; Protection Rating IP68, suitable for harsh environments.

$ 3401.00

Polarography dissolved oxygen Measurement range 0.00~ 50.00mg/L, Response Time ≤ 45s, support automatic temperature compensation and salinity compensation, with IP65 Protection Rating, Data storage 500 sets and GLP standards.

$ 674.00

With pH, ORP, dissolved oxygen three measurement functions, support automatic temperature compensation and salinity compensation, built-in 500 data storage, equipped with USB Communication interface, Measurement accuracy of +/- 0.002pH.

$ 630.00

An ultra-thin 12mm diaMeter design for easy measurement in narrow containers, built-in thermistor temperature sensor compensates for 0 to 50 ° C variations, PEI body material and PTFE oxygen permeable membrane for increased durability and maintenance efficiency.

$ 987.00

With 7-inch TFT display and 1000 sets of data storage, support automatic temperature, salinity and atmospheric pressure compensation, Measurement range 0.00~ 20.00mg/L, accuracy +/- 0.2mg/L, suitable for a variety of dissolved oxygen related paraMeters determination.

$ 612.00

Support conductivity 0-200mS/cm and dissolved oxygen 0-20mg/L measurement, with automatic temperature compensation, ElectRode diagnostic function and IP54 Protection Rating, Data storage up to 450 groups and support Bluetooth printout.

$ 841.00

Can simultaneously measure pH, dissolved oxygen and temperature paraMeters, support automatic temperature compensation and ElectRode diagnosis, data storage capacity of 450 groups, with statistical analysis and Bluetooth printing function, dustproof and waterproof grade IP54.

$ 812.00

Built-in three measurement units can simultaneously detect pH, Conductivity Detector and dissolved oxygen, support automatic temperature compensation and ElectRode diagnosis, with IP54 Protection Rating, data storage capacity of 500 groups, support GLP specification to achieve data traceability.

$ 1142.00

Equipped with polarographic dissolved Oxygen electRode, Measurement accuracy +/- 0.5mg/L, support automatic temperature compensation and manual salinity compensation, full waterproof design to ensure harsh environment use, built-in a number of custom paraMeter settings.

$ 361.00

Articles

Differential pressure method gas permeameter measures oxygen transmission rate of films.
This article introduces the method of measuring the oxygen transmission rate of films using the differential pressure gas permeation apparatus.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Application of Paper Absorbency Tester in Sizing Process
The paper absorbency tester evaluates the absorption performance of paper by measuring the penetration of liquid on the paper. In the sizing process, sizing agents alter the hydrophilicity of the paper fiber surface, thereby affecting the paper's resistance to liquids.
Salt spray test chamber evaluates the protective performance of powder coatings
The salt spray test chamber accelerates the evaluation of the corrosion resistance of powder coatings by simulating a salty and humid environment. The test is based on electrochemical principles, where salt spray penetrates coating defects and initiates corrosion of the metal substrate. During operation, parameters such as temperature and sedimentation rate must be strictly controlled, and standards such as ISO and ASTM must be followed.