Refrigerated Temperature-Controlled Circulator

The refrigeration temperature control circulation bath regulates the temperature of the liquid inside the tank through compressor or thermoelectric refrigeration technology, and maintains temperature stability with the assistance of a circulation pump. It is used in laboratories to provide a constant temperature environment for reactors and instruments, commonly found in material testing and chemical reaction processes.
Selection
When selecting, consider that the temperature range should cover experimental needs, the cooling power should match the heat dissipation load, the tank capacity should fit the equipment size, the temperature control accuracy should meet experimental standards, the material should have corrosion resistance, and check safety protection features such as over-temperature alarms.

Terms

Instruments

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

The internal resistance range is less than or equal to 5mΩ, the peak current is up to 1000A, and it is automatically controlled by PLC. It has the function of temperature monitoring and can set short-circuit stop conditions to ensure accurate and reliable test data.

$ 1632.00

With heating and cooling functions, Temperature range -20~ 100 ℃, Fluctuation +/- 0.05~ 0.1 ℃, can be 10-stage program control, to achieve timing thermostatic, heating and cooling.

$ 1372.00

With heating and cooling functions, Temperature range -10~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, support 10-stage program control and external communication, pump Flow rate 12L/min, suitable for internal and external circulation applications.

$ 1146.00

Temperature range -20 ℃ to 150 ℃, equipped with pressure/suction pump and Pt100 Sensor, supports multi-stage program control and external temperature sensor, with hardware over-temperature protection and multiple safety modes.

$ 977.00

Temperature range -20 ℃ to 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1K, equipped with pressure/suction pump and hardware over-temperature protection, supports multi-stage program control and external Sensor interface.

$ 909.00

It can precisely control the temperature in the range of room temperature to 300 ° C, Temperature Fluctuation +/- 0.05 ° C, equipped with high temperature centrifugal jet circulation pump, head 5 Meters, support the internal and external circulation system, and achieve a highly uniform temperature field.

$ 672.00

Temperature range -20 ℃ to 150 ℃, Temperature Fluctuation +/- 0.05~ 0.1K, using pressure/suction pump and Pt100 Sensor, support multi-stage program control and external Communication interface.

$ 1090.00

Temperature range -10~ 95 ℃, using Air-Cooled fully enclosed Compressor, high cooling efficiency, low noise, the inner Tank is made of stainless steel, good thermal insulation performance.

$ 2426.00

Temperature range -5~ 95 ℃, using Air-Cooled fully enclosed Compressor and overall foaming process, high cooling efficiency and good thermal insulation performance, low noise and vibration.

$ 1687.00

Temperature range -20~ 95 ℃, using Air-Cooled fully enclosed Compressor, efficient and fast cooling, low noise and less vibration, the inner Tank is made of stainless steel, and the thermal insulation performance is good.

$ 1676.00

Temperature control accuracy of +/- 0.05 ℃, support room temperature to 300 ℃ range of water and oil dual-use, equipped with high temperature centrifugal pump head 5 Meters, domestic circulation system to achieve uniform temperature field.

$ 825.00

Temperature range from room temperature to 300 ℃, Temperature Fluctuation +/- 0.05 ℃, using non-heat centrifugal circulating pump and PID automatic temperature control to achieve a highly uniform temperature field, with a variety of Safety protection functions.

$ 2510.00

Temperature range room temperature to 300 ℃, Temperature Fluctuation +/- 0.05 ℃, the use of non-heat centrifugal circulation pump to avoid their own heat impact temperature field, with low water level protection and alarm function.

$ 2061.00

Can work at room temperature to 300 ℃ range, using high temperature centrifugal jet circulation pump, head up to 5 Meters, equipped with PID automatic temperature control, digital resolution 0.01 ℃, Temperature Fluctuation +/- 0.05 ℃, domestic circulation system to achieve a high degree of uniform temperature field.

$ 914.00

Articles

The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.