Metal Wall Thickness Meter

The metal wall thickness gauge measures the round-trip time of ultrasonic waves propagating and reflecting within a material to calculate thickness. It is used for inspecting the wall thickness of metal pipes, containers, and other structures, and is widely applied in industrial maintenance and quality control.
Selection
When selecting a metal wall thickness gauge, it is essential to consider the measurement range to match the thickness of the object being measured, the material type to adapt to different metals, environmental factors such as temperature that may affect accuracy, the probe size to suit the shape of the surface being inspected, and the ease of operation to meet daily usage needs.

Terms

Standards

Instruments

With bottle bottom and bottle wall double measurement function, test resolution of 0.001mm, no power supply, easy and fast operation, suitable for large bottles such as wine bottles and infusion bottles.

$ 661.00

With bottle bottom and bottle wall double measurement function, test resolution of 0.001mm, no power supply, easy and fast operation, suitable for small volume bottles such as ampoules and vials, general structure design is simple and durable.

$ 622.00

Adopting 15mm wall thickness high-quality Organic Glass sealing barrel, equipped with automatic constant pressure gas filling function, Vacuum Level range -90~ 0kPa, to achieve automated testing process without manual operation.

$ 748.00

With paint penetration measurement ability, accurate measurement of wall thickness without removing coatings, thickness range 2.5~ 125mm, accuracy +/- 0.03mm, support multi-echo and single-echo mode switching, suitable for detection needs of different surface conditions.

$ 2739.00

Measurement range of 0~ 1250μm using magnetic Induction principle, with +/- 3% error accuracy and 0.1μm resolution, supports single continuous two Measurement mode, equipped with wear-resistant metal probe to ensure measurement Stability.

$ 320.00

The large diaMeter design is used to facilitate sample pouring in and out, the inner wall arc transition is easy to clean, and the accuracy is controlled within 0.2% to ensure reliable measurement results.

$ 117.00

Measurement range 0.65-400 mm, accuracy up to +/- 0.04mm, support 3000 data storage and USB transmission, automatic zero calibration and a variety of Measurement modes.

$ 964.00

Temperature range -40~ 150 ℃, Temperature Uniformity ≤ 2.0 ℃, mirror stainless steel inner wall and binary cascade refrigeration system, equipped with observation window and anti-condensation device.

$ 8687.00

Using aluminum alloy material, the accuracy is controlled within 0.2%, the inner wall arc transition is easy to clean, and the lid small hole design can overflow excess samples to avoid bubbles and improve the test accuracy.

$ 127.00

Using aluminum alloy material, the accuracy is controlled within 0.2%, the inner wall arc transition is easy to clean, and the lid hole design can overflow excess samples to avoid bubbles and improve the test accuracy.

$ 127.00

Adopt binary cascade refrigeration mode, temperature range -40 ℃ to 150 ℃, equipped with mirror stainless steel inner wall and automatic energy saving control system to ensure the test environment is stable and uniform.

$ 13044.00

Measurement range 0~ 1500 microns, error +/- 1%, support magnetic Induction principle, IP65 Protection Rating and 250 reading storage, suitable for ferrous metal substrate nonmagnetic coating environment.

$ 890.00

Temperature range -70~ 150 ℃, volume 1000L, mirror stainless steel inner wall and binary cascade refrigeration to ensure Temperature Uniformity ≤ 2.0 ℃, suitable for a variety of environment simulation test.

$ 16272.00

Mirror stainless steel inner wall and fiberglass insulation material, temperature range -70~ 150 ℃, uniformity ≤ 2.0 ℃, equipped with automatic adjustment refrigeration system and anti-condensation device to ensure stability testing environment.

$ 15307.00

Temperature range -40~ 150 ℃, Fluctuation ≤ 0.5 ℃, mirror stainless steel inner wall and fiberglass insulation material, equipped with observation window and anti-condensation device, support automatic adjustment of refrigeration operation.

$ 10898.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Controllable Coating of Composite Separator Coatings for Lithium Metal Batteries
This article primarily explores the controllable coating technology for composite separator coatings in lithium metal batteries.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.