The three-box structure is used to realize the static test sample, the strong cooling hot air circuit switching technology, the temperature conversion time is less than or equal to 10 seconds, the temperature recovery time is less than or equal to 5 minutes, and the temperature control function is independent in the high temperature zone, the low temperature zone and the test zone.
The Three-Box structure is used to distinguish the high temperature zone, the low temperature zone and the test zone, and the air passage is switched to achieve temperature impact. The maximum cycle period is 9999 times, and the Temperature range is -60~ 150 ° C. It supports automatic cycle or manual selective impact.
The three-box structure realizes independent temperature control in the high temperature zone, the low temperature zone and the test zone. The temperature conversion time is within 10 seconds, and the temperature control accuracy reaches +/- 0.5 ° C. The air circuit switching method is used for rapid Impact testing to improve the material testing efficiency.
The three-box structure realizes the separation of the high temperature zone, the low temperature zone and the test zone, the air passage switching mode intRoduces the temperature for Impact, the temperature conversion time is ≤ 10 seconds, the temperature control accuracy is +/- 0.5 ℃, and the microcomputer equilibrate temperature control system and the double-stage Compressor chill down.
The three-box structure is used to achieve a completely static test zone, with a temperature conversion time of ≤ 10 seconds and a temperature recovery of ≤ 5 minutes. It has an Impact range of 150 ° C in the high temperature zone and -55 ° C in the low temperature zone, meeting the needs of rapid temperature change testing.
The three-box structure is used to achieve independent temperature control in the high temperature zone, low temperature zone and test zone, with a temperature conversion time of less than or equal to 10 seconds. It is equipped with rigid polyurethane foam insulation materials and supports 2 or 3 boxes of Impact mode to meet different standard testing requirements.
Adopt three-box heat storage and cold storage structure, temperature conversion time ≤ 10 seconds, Temperature range -65 ℃~ + 150 ℃, with independent temperature control functions in high temperature zone, low temperature zone and test zone, and can perform 2-box or 3-box Impact mode.
The three-box heat storage and cold storage structure is adopted to achieve rapid temperature conversion of ≤ 10s, and the temperature recovery time is ≤ 5 minutes. It supports Impact testing at 150 ° C in high temperature zone and -40 ° C in low temperature zone, and has program memory and Linear dispersion recording functions.
The three-box structure design realizes the rapid switching between the high temperature zone of 60 ° C to 150 ° C and the low temperature zone of -10 ° C to -45 ° C. The temperature conversion only takes 10 seconds to complete, and the temperature recovery time does not exceed 5 minutes. The air circuit switching method is used to ensure the test Stability.
The three-box heat storage structure is used to realize forced air circuit switching, the temperature recovery time is less than or equal to 5 minutes, and the conversion only takes 10 seconds. With independent temperature control in high temperature zone, low temperature zone and test zone, it can perform 2-box or 3-box Impact mode to meet different test needs.
Using Three-Box structure air circuit switching technology, Temperature range covers -60 ° C to 150 ° C, the maximum cycle period is 9999 times, with binary refrigeration system to achieve rapid cooling, support automatic cycle and manual Impact mode.
The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.
The independent control of the dual temperature zone can simultaneously digest different paraMeters, the 30-hole design supports digestion capacity above 12mL, the temperature control accuracy is +/- 0.5 ° C, the temperature is raised to 165 ° C within 12 minutes, and the fully enclosed transparent protective cover ensures safety.
Adopting independent control design of hot and cold box, the temperature conversion time does not exceed 15 seconds, and the recovery time is within 5 minutes. Equipped with safety interlock function and standard lead hole tube, it enhances test efficiency and operation safety.
The three-box structure realizes independent temperature control in the high temperature and low temperature area, the temperature conversion time is ≤ 10 seconds, the temperature control accuracy is +/- 0.5 ℃, the air circuit switching Impact mode is adopted, and the microcomputer equilibrating temperature control system is equipped.