Tape Holding Adhesion Testing Machine

The Tape Holding Adhesion Tester measures the time a tape sample remains adhered without falling off an inclined plate surface by securing the tape specimen and suspending a standard weight. This equipment is used to evaluate the persistent adhesion performance of pressure-sensitive tapes and is commonly applied in quality control during tape production and adhesive research and development.
Selection
When selecting, ensure the test plate material matches the actual application surface, the weight range of the weights covers product specifications, the temperature and humidity control functions adapt to different environmental conditions, the timing accuracy meets standard requirements, and the fixture design ensures no slippage of the specimen.

Terms

Standards

Instruments

With a 5/10 station design and room temperature range, multiple samples can be tested simultaneously, and the adhesion and durability performance can be accurately evaluated through the suspension weight measurement of the displacement or complete disengagement time.

$ 427.00

The adhesive force of the tape is 4.3N/cm, and the principle of cross-cut method is adopted, which is suitable for adhesion testing. The performance is stable and non-degumming, and the test results are accurate and reliable.

$ 166.00

Tack is good and non-degumming, adhesion reaches 7.6 N/cm, mass performance is stable, suitable for cross-cut adhesion testing, to ensure accurate film integrity assessment.

$ 174.00

Equipped with 10-station synchronous test capability, 1000g weight and 1-999999 minute Timer, using SUS #304 steel plate to ensure test accuracy, and automatically recording tape peeling time.

$ 748.00

With 5 groups of independent testing capabilities, the temperature control range is from room temperature to 70 ° C, and the hot air circulation method is used to ensure Temperature uniformity.

$ 1284.00

Tack testing to assess adhesion by measurement of displacement or peeling time under specified weight. With thermostatic test chamber, multi-national standards are supported and the operation process is clear.

$ 2090.00

Using 2000g +/- 5g roller load and 300mm/min rolling speed to ensure that the adhesive tape sample is flat and evenly adhered to the standard substrate, in line with CNS-11888 and PSTC-8 design standards.

$ 524.00

Equipped with 1000g weight and 1~ 999999 minute Timer, using SUS #304 steel plate to ensure test accuracy and meet a number of national standards.

$ 414.00

10 station design can carry out multiple sets of tests at the same time. Temperature range RT +~ 250 ℃, hot air circulation to ensure uniform temperature. With over-temperature and electric overload automatic power-off protection, improve operation safety.

$ 1390.00

Complies with ISO 8502-3 standard, can assess the size and size of surface dust, ensure cleaning before lame plating, improve coating adhesion, suitable for passing test and long-term recording.

$ 169.00

35Mm cross-cut length and 1mm pitch design, stainless steel material to ensure dimensional accuracy, equipped with tape and brush for film adhesion testing.

$ 151.00

Manual control of holding pressure is easy to operate, 15mm thick Organic Glass sealing bucket enhances compressire strength, Vacuum Level range -90~ 0kPa, resolution accurate to 0.1kPa, built-in time display automatic timing clear.

$ 851.00

The equipment tests the initial Tack by short contact between steel ball and adhesive tape sample at a small pressure, adjustable tilt angle 0~ 60 °, rolling ball range 1/32 inch to 1 inch, suitable for a variety of material adhesion evaluation.

$ 240.00

The adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel ≥ 80mm. The integrity of the paint film was evaluated by seven grades, and the operation was simple and conformed to the GB/T1720 standard.

$ 444.00

Measured value 500N, suitable for tape, PCB, adhesive tape and other materials disbonding force test, supporting the Force Gauge test bench.

$ 89.00

Articles

Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.
Evaluation of Coating Adhesion Grade by Cross-Cut Tester Combined with Tape Method
This article introduces the method of evaluating coating adhesion using a paint film cross-cut tester combined with the tape method.
The film applicator applies hydrocolloid adhesive onto medical dressings.
The coating machine is used to apply a hydrocolloid adhesive evenly onto the substrate of medical dressings. This adhesive, made from hydrophilic polymer materials, maintains its adhesion and comfort in moist environments.
Cross-cut tester combined with adhesion test tape for evaluating coating peel-off.
The cross-cut test, paired with adhesion test tape, is a commonly used method for evaluating coating adhesion. It involves using a cross-cut knife to score a grid pattern on the coating surface, followed by the rapid peeling of specialized tape. The adhesion level is then assessed by observing the extent of coating detachment.
Adhesion Retention Tester Evaluates the Cohesive Strength of Hot Melt Adhesive
This article introduces how to use a tack retention tester to evaluate the cohesive strength of hot-melt adhesives. During testing, a sample coated with hot-melt adhesive is attached to a test plate, and a weight is hung to apply a continuous shear stress. The time until detachment or the displacement is recorded, which directly reflects the internal cohesion of the adhesive.
Standard Procedure for Cross-Cut Test of Ink Adhesion
The cross-cut test is a standard method for testing ink adhesion. It involves cutting a grid pattern on the coated surface, applying and then peeling off adhesive tape, and observing the extent of ink peeling to evaluate the adhesion grade.
Application of Initial Tack Tester in the Adhesive Products Industry
The initial tack tester is used to measure the adhesive force of adhesive products upon initial contact, which is important for the research, development, and quality control of products such as tapes and labels. It simulates the process of materials making contact and then separating, records relevant data, and helps evaluate performance.
Tensile testing machine tests the tensile strength of industrial tape.
This article explains how to use a tensile testing machine to test the tensile strength of industrial tapes. Tensile strength is a key indicator for measuring the mechanical properties of tapes, and testing must comply with international standards such as ISO and ASTM.
The 180-degree peel strength test for tape shows a 50% deviation in data due to misalignment of the sample.
In the 180-degree peel strength test of adhesive tape, if the sample is misaligned, the test data may drop by about half. This is because misalignment causes uneven force distribution during peeling, reducing the effective peel strength.