High Molecular Emulsifier

The high-molecular emulsifier disperses immiscible liquids into stable emulsions through high-speed shearing and mechanical stirring. It utilizes the rotor-stator to generate strong shear forces, breaking down and refining liquid droplets. It is used in the preparation of emulsions in industries such as coatings, inks, and adhesives, achieving uniform mixing of materials and enhanced stability.
Selection
When selecting, consider the material viscosity, processing capacity, and particle size requirements. Pay attention to the matching of equipment power and rotational speed, and ensure the material is corrosion-resistant. Choose explosion-proof or standard models based on the production environment, and compare the energy consumption and maintenance costs of different manufacturers. Refer to the compatibility with existing production lines and ensure the sealing structure is reliable.

Terms

Standards

Instruments

The water pRoduction rate reaches 10L/h, the water intake Flow velocity is 1.0L/min, and the RO membrane intelligent anti-scale washing and automatic domestic circulation system are used to ensure stable water quality and meet the high standard requirements of the laboratory.

$ 2300.00

The water pRoduction rate reaches 5L/h, the water intake Flow velocity is 0.8L/min, and the RO membrane intelligent anti-scale flushing and automatic domestic circulation system are supported to ensure the stability of ultrapure water quality, which is suitable for a variety of experimental needs.

$ 1897.00

Flow velocity 1.5L/min, reverse osmosis (RO) membrane and purification column are used to remove trace ions efficiently, and intelligent microcomputer control realizes automatic operation and online water quality monitoring.

$ 2784.00

The water pRoduction rate is 10L/h, and the eight-stage purification system includes reverse osmosis (RO) membrane and ultra-pure polishing column, providing 18.25MΩ. cm ultra-pure water quality, supporting multiple water intake modes and intelligent control functions.

$ 4027.00

Flow velocity 1.5L/min, reverse osmosis (RO) membrane and purification column, intelligent microcomputer control to achieve automatic operation and online water quality monitoring, effective removal of trace ions.

$ 3430.00

The eight-stage deep purification system ensures that the water quality is pure, the resistivity of the pRoduced water is 18.25MΩ .cm, and it is equipped with an intelligent Control system to realize automatic monitoring and a variety of water intake modes to meet the strict experimental requirements.

$ 4511.00

The water pRoduction rate reaches 5L/h, the eight-stage purification system includes reverse osmosis (RO) membrane and ultra-pure polishing column, the desalination and sterilization rate is over 99%, supports intelligent control and a variety of water intake modes, suitable for laboratory environment use.

$ 3543.00

The maximum speed is 14500rpm, the maximum centrifugal force is 14000xg, and it only takes 15 seconds to accelerate to the highest speed. The unique airflow guidance design keeps the sample low temperature, and the aluminum alloy rotor can autoclaving at high temperature for ultra-quiet operation.

$ 967.00

It adopts 96-hole 0.2ml design, supports 100 ℃ high temperature environment, is compatible with a variety of centrifuge tube modules, and meets the thermostatic treatment requirements of different specifications of samples.

$ 148.00

It supports high-temperature treatment at 100 ° C and can simultaneously accommodate 32 0.2ml and 25 1.5ml centrifuge tubes with accurate temperature control, making it suitable for high-throughput experiments with multiple samples.

$ 148.00

The double Tank design is used to achieve high-throughput grinding, the vibration speed is adjustable from 60 to 1800rpm, and the discharge particle size is 5 to 10 μm. It supports dry grinding, wet grinding and low temperature grinding, and effectively protects the molecular structure of heat-sensitive materials.

$ 5697.00

3 gear Rotation speed can be adjusted up to 18000rpm, suitable for 1.5ml centrifuge tube, grinding pestle is easy to disassemble and can be sterilized at high temperature, reducing sample loss, light and compact battery life over 1 hour.

$ 135.00

The static capacity method is used for testing, with a specific surface area ranging from 0.01 m2/g to no upper limit, and a pore size analysis of 3.5 to 5000 angstroms. The modular stainless steel gas circuit design ensures a high vacuum, and the metal dewar bottle maintains a constant temperature. It supports a variety of theoretical model calculations.

$ 23956.00

With double Tank grinding and low temperature function, vibration speed 60-1800rpm, discharge particle size 5~ 10μm, can quickly process heat sensitive materials, prevent molecular degradation, support high throughput Sample Handling.

$ 5610.00

Equipped with 3-speed speed range 5000-18000rpm, battery life of more than 1 hour, ground pestle can be disassembled and sterilized at high temperature to reduce sample loss, suitable for a variety of biological sample processing.

$ 122.00

Articles

Friction and wear testing machine evaluates the wear resistance of self-lubricating polymer materials.
This article introduces how to use a friction and wear testing machine to evaluate the wear resistance of self-lubricating polymer materials. It explains the working principles of the testing machine, including the basic formulas for measuring the friction coefficient and wear rate.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Differential Scanning Calorimetry measures the phase transition temperature of liquid crystal polymers.
This article introduces the method of determining the phase transition temperature of liquid crystal polymers using a differential scanning calorimeter. The differential scanning calorimeter analyzes the phase transition behavior of materials by comparing the heat difference between the sample and a reference material, recording the heat flow curve during temperature changes.
Differential Scanning Calorimetry measures the heat of curing reaction of thermosetting polymers.
Differential scanning calorimetry is a commonly used technique for studying the curing reactions of thermosetting polymers. It measures the heat released by a sample during heating to obtain key parameters such as reaction enthalpy and curing temperature.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Four-probe resistivity tester measures the sheet resistance of conductive polymer films.
This article introduces the method of measuring the sheet resistance of conductive polymer films using a four-probe resistivity tester. Sheet resistance is an important parameter for evaluating the conductivity of films.
Differential Scanning Calorimetry for Measuring the Degree of Cure of Polymer Optical Waveguide Materials
This article introduces a method for determining the degree of curing in polymer optical waveguide materials using a differential scanning calorimeter. The degree of curing is a key indicator affecting material performance, and this instrument quantitatively analyzes it by measuring the thermal effects during the curing reaction.
The film applicator applies hydrocolloid adhesive onto medical dressings.
The coating machine is used to apply a hydrocolloid adhesive evenly onto the substrate of medical dressings. This adhesive, made from hydrophilic polymer materials, maintains its adhesion and comfort in moist environments.
Application of Roll-to-Roll Coating Machines in the Energy Storage Field
A roll-to-roll coating machine is a continuous coating equipment. Its core process involves uniformly applying slurry onto the surface of a flexible substrate (such as metal foil or polymer film), followed by steps like drying and rolling to produce continuous coated materials.
UV aging test chambers are used for the aging evaluation of polymer materials.
The UV aging test chamber accelerates the aging process of polymer materials by simulating ultraviolet radiation from sunlight, combined with temperature and humidity control, to evaluate their durability.
Application of Tensile Testing Machines in Polymer Materials
A tensile testing machine is a device used to test the mechanical properties of materials by stretching specimens and measuring force and deformation, thereby evaluating the toughness of materials such as plastics and rubber.