Semi-automatic flash point Tester

The semi-automatic flash point tester causes the sample to volatilize through controlled heating and captures the minimum flash ignition temperature when exposed to an open flame. It is used for testing the flammability of liquids such as paints and inks, ensuring safety in production and storage. During operation, manual ignition and observation are required, while the instrument records temperature data.
Selection
When selecting, ensure the detection standards comply with industry regulations and the sample volume is compatible with the instrument's capacity. Pay attention to the accuracy of temperature control and the integrity of protective devices. Consider the daily testing volume when choosing the operational complexity, and ensure maintenance parts are easily accessible. The ventilation conditions of the environment must meet experimental requirements.

Terms

Standards

Instruments

Using platinum temperature sensor and digital Optical inspection technology, temperature control accuracy 0.1 ℃, can process 2 samples at the same time, with video recording playback function, support 0.1-10 ℃/min heating rate.

$ 3946.00

Using electronic ignition and flash detection module, test process automation, Temperature range RT +~ 400 ℃, Repeatability +/- 4 ℃, with over-temperature protection and anti-dry burning function.

$ 5399.00

Using 7-inch true color Touchscreen and 32-bit microprocessor, Temperature range RT +~ 400 ℃, with automatic atmospheric pressure compensation and over-temperature protection function, the test process is fully automated.

$ 5399.00

Adopt ARM microprocessor and color LCD display, with automatic heating, sweeping, ignition function, Repeatability ≤ 110 ℃ +/- 1 ℃, support atmospheric pressure correction and forced Air-Cooled, easy and reliable operation.

$ 2116.00

Using ARM microprocessor and German technology, the test can be completed with only 1-2ml of trace samples. With automatic heating, sweeping, ignition and printing functions, no external combustible gas is required, and the operation is simple and reliable.

$ 4269.00

Using ARM microprocessor and color liquid crystal display, with automatic heating sweep ignition function, Temperature range 40~ 400 ℃, can store 1000 measurement results, support atmospheric pressure correction and forced Air-Cooled.

$ 2116.00

The black background counting cell is used with annular fluorescent lamp side-shot illumination, and the colony contrast ratio is clear; the counter capacity is 0-999, and the inclined design of the cell surface is easy to observe, which can reduce the labor intensity of the experimenters.

$ 170.00

With an impact speed of 2.9m/s or 3.8m/s, it supports a variety of sample sizes, uses semi-automatic control to improve operation efficiency, and can display information in real time and print out the results.

$ 1138.00

The CMOS integrated circuit is used to ensure stable counting, and the 7W energy-saving ring lamp side-shot illumination makes the colony contrast clear. The counter capacity is 0-999 to meet the needs of conventional detection. The probe pen marking function is avoided, and the repeability count is performed.

$ 151.00

Using platinum plate or ring method measurement, the range is 0~ 400mN/m, the minimum resolution is 0.1mN/m, the manual lifting and lowering points are fast and micro-adjusted, and the output data of RS232C interface is supported.

$ 1413.00

ElectRode planar design, direct measurement of semi-solid substances, Measurement accuracy of 0.05pH, support automatic temperature compensation and 2 point calibrating, waterproof structure to ensure harsh environment use.

$ 159.00

The XY axis displacement platform and the lifting measurement platform are used to facilitate accurate fine-tuning and measurement of small samples such as O-rings; the servo system imported from Japan ensures accurate positioning, and the built-in micro printer supports data output.

$ 14274.00

Measuring methods of platinum plate and platinum ring are supported, with resolution up to 0.01mN/m, equipped with fast fine-tuning manual lifting platform, and can display data in real time through RS232 interface.

$ 2042.00

Measurement range 50~ 40000FPM, accuracy +/- 0.05% n + 1d, Sampling time 0.3 seconds. With automatic stop flash to extend life, external trigger to achieve automatic pattern tracking, accurate measurement Rotation speed without contact.

$ 344.00

High Accuracy temperature control technology, Temperature range RT +~ 400 ℃, resolution 0.1 ℃, support 0.1~ 20 ℃ stepless heating, high-resolution video observation melting process, no map but can store 400 data.

$ 2607.00

Articles

Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Flash Point Tester Selection: Applicable Scenarios for Closed Cup and Open Cup Methods
This article introduces the differences between the closed-cup method and the open-cup method in flash point testing.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.