Iron Panel GlossMeter

The metal plate gloss meter works by projecting light onto the sample surface at a fixed angle, with a detector measuring the intensity of the reflected light and converting it into a gloss value. It is used to quantify the specular reflection capability of metal sheet surfaces, aiding in quality inspection to assess coating uniformity and surface treatment effectiveness.
Selection
When selecting, ensure the measurement angle matches the sample's gloss range: use a 20° angle for high gloss, 60° for standard gloss, and 85° for low gloss. Verify that the instrument's measurement range covers the sample being tested, check the validity of the calibration certificate, and confirm that the measurement aperture is suitable for the curvature dimensions of the workpiece.

Terms

Standards

Instruments

Supports iron-based and non-iron-based material measurement with accuracy of +/- 1~ 3% or +/- 2.5 µm, provides split Probe for enhanced maneuverability, automatically recognizes matrix materials and remembers calibrated values.

$ 527.00

With iron-based and non-iron-based dual-use function, resolution up to 0.1um, test range 0~ 1250um, support single and continuous measurement, automatic identification of matrix material, stable and portable operation.

$ 356.00

Measurement range 0-999 ppb with accuracy +/- 20 ppb +/- 5% for rapid iron concentration detection.

$ 215.00

Fully pneumatic design ensures stable operation, adjustable spray gun settings for precise atomization and film thickness control, and magnetic panel supports multiple substrate tests.

$ 59126.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 1250μm, Probe with line can measure grooves and complex positions, automatically identify iron and non-iron substrates, with single point and two point Adjustment.

$ 196.00

Measurement range 0.00-5 mg/L, Color intensity is proportional to concentration, providing 100 tests, suitable for the analysis of iron content in various liquid samples.

$ 160.00

With 60 ° Measurement Angles and 9 * 15mm Measuring Area, the repeatability is up to +/- 1GU, with automatic check and correction standard board function and 30-second automatic shutdown design, which meets the requirements of JJG696 secondary working Glossmeter.

$ 167.00

It can reduce the noise of the air Compressor by 10dB. The iron shell structure is sturdy and durable, and it is equipped with wheels for easy movement. It is suitable for noise reduction requirements of air Compressors with different pump heads.

$ 315.00

Using 2.0MHz Frequency Probe, Measurement range 2.0~ 400.0mm, dedicated to the thickness detection of coarse crystal materials such as cast iron, the lower limit of pipe measurement Φ 30 * 4mm.

$ 219.00

Equipped with double spray guns to achieve uniform lame plating, the lifting range of the spray gun is adjustable from 10-500mm, the integrated air filtrate adjustment system supports magnetic or vacuum panel fixing, and improves the coating test Repeatability.

$ 67560.00

With intelligent acceleration function, the stirring speed is adjustable from 0 to 1250rpm, the maximum stirring capacity is 2 liters, the Timer Range is 0 to 999 minutes, and the stainless steel panel is durable and easy to clean.

$ 190.00

The iron shell structure is equipped with moving wheels, which can reduce the running noise of the four-pump air Compressor by 10 dB, effectively controlling it within the comfort range of 51 +/- 5 dB, and the bottom wheels are convenient for equipment movement.

$ 380.00

Using 2.0MHz Frequency, specially designed for cast iron and other coarse crystal materials, concave curved surface structure is suitable for special workpiece shape, Measurement range covers 2.0~ 400.0mm, and the lower limit of pipe measurement is Φ 30 * 4mm.

$ 283.00

Support 0.1-1 steel plate and 0.1-2 Aluminum Panel test, can complete 0T to 1T multi-stage bending, equipped with pliers pressing device and tape adhesion inspection function, to meet the standard bending test process.

$ 782.00

It can reduce the operating noise of the air Compressor by 10 decibels, and is equipped with moving wheels for easy handling. The iron shell box structure effectively isolates the transmission of noise, making it suitable for air Compressor equipment with various pump head configurations.

$ 315.00

Articles

Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Gloss meter measures the gloss consistency of resin coating film surfaces.
This article introduces how to use a gloss meter to measure the gloss consistency of resin coating film surfaces.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
Glossmeter 75-degree angle measurement for paper gloss
This article introduces the principle and method of measuring paper gloss using a 75-degree specular gloss meter. Gloss is defined as the ratio of the light reflected from the paper surface to that reflected from a standard reference plate, with the 75-degree angle commonly used for measuring medium to high gloss papers.
Three-angle gloss meter for evaluating coatings with different gloss levels
Glossiness is a key indicator for evaluating the optical properties of a surface, defined as the ratio of the reflected luminous flux to the incident luminous flux, typically expressed as a percentage or in gloss units.
Method for measuring the gloss of ink surfaces using a gloss meter
This article introduces the method of measuring the surface gloss of ink using a gloss meter. Gloss is a key indicator of the visual quality of ink, and the instrument quantifies gloss by measuring reflected light at specific angles.
The use of a gloss meter in evaluating the surface gloss of printing paper and art paper.
Gloss meters quantify paper gloss by measuring surface reflected light, with 20°, 60°, and 85° angles commonly used for high, medium, and low gloss surfaces, respectively. The gloss characteristics of printing paper and art paper differ, so the appropriate measurement angle should be selected based on the estimated gloss level.
Determination of specular gloss: Selection criteria for instruments at different angles (20°/60°/85°)
Specular gloss is a measure of a material's ability to reflect light, calculated by comparing the reflected luminous flux of a sample with that of a standard plate. Three angles—20°, 60°, and 85°—are commonly used for measurement, corresponding to high-gloss, medium-gloss, and low-gloss surfaces, respectively.