Stainless Steel Tabletop Viscosity Cup

The stainless steel bench-top viscosity cup calculates viscosity by measuring the time it takes for a fluid to flow out through a standard aperture. It is used for quality control of fluids such as paints and inks. During operation, the cup is filled with the sample, and the outflow time is recorded to convert into a viscosity value.
Selection
When selecting, consider matching the cup type number with the viscosity range of the fluid being measured, and choose standardized sample formats such as ISO/ASTM according to standards. Pay attention to the smoothness of the cup opening and the accuracy of volume. Clean the flow channel promptly with solvent after use to maintain smooth flow.

Terms

Instruments

Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, aperture 1.90mm, viscosity measurement range of 10~ 35cSt, flow time of 55~ 100 seconds, suitable for liquid viscosity evaluation.

$ 130.00

The stainless steel material is durable, the inner wall of the Cup body is smooth to ensure stable Flow velocity, the diaMeter of the flow hole is 2mm, and the viscosity range of 70cSt can be measured. Precision machining ensures measurement accuracy.

$ 190.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the diaMeter of the flow hole is 2.53mm, the viscosity range is 25~ 120cSt, and the liquid viscosity is evaluated by measuring the outflow time, which conforms to the ASTM standard design.

$ 130.00

Portable design with long stainless steel handle for easy operation. Outflow aperture 5.8mm, can measure 200-1200cSt viscosity range, corresponding to outflow time 30-100 seconds. Cup body aluminum alloy with stainless steel nozzle, both lightweight and corrosion resistance.

$ 285.00

Using stainless steel aperture 5.20mm, viscosity measurement range of 200~ 1200cSt, aluminum alloy Cup body sturdy and durable, in line with ASTM D1200 standard, suitable for laboratory accurate measurement of fluid viscosity.

$ 170.00

6Mm diaMeter outflow hole design, stainless steel material durable anti-corrosion, can be freely replaced with filter holder, expand the scope of application of viscosity Cup test, to meet different viscosity measurement needs.

$ 150.00

Flow hole diaMeter 6mm, Cup height 74mm, stainless steel material, in line with international standards, suitable for Newtonian or near newtonian fluid, providing accurate viscosity assessment.

$ 587.00

The stainless steel material is durable and easy to clean, the inner wall of the Cup body is smooth to ensure the stability of Flow velocity, the diaMeter of the precision machining flow hole is 4mm, and the viscosity measurement range is 80~ 700cSt, which meets the requirements of multi-industry standards.

$ 190.00

8Mm diaMeter outflow hole design, durable stainless steel material, can be freely replaced with filter holder, expand the test range of viscosity Cup, meet different viscosity measurement needs.

$ 155.00

Made of stainless steel, the diaMeter of the flow hole is 5mm, the Cup height is 74mm, and the viscosity is calculated by measuring the liquid outflow time, which meets international standards and has a unique serial number.

$ 559.00

6Mm flow hole design, measurement viscosity range 188~ 684cSt, aluminum alloy Cup with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

Using 5mm flow hole design, the measurement viscosity range of 91~ 326cSt, aluminum alloy Cup body with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

4Mm diaMeter outflow hole design, stainless steel material durable anti-corrosion, can be replaced freely with filter holder, expand the scope of application of viscosity Cup test.

$ 155.00

Aperture 4.12mm, viscosity measurement range of 70~ 370cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.
An article tells you how to choose a viscosity cup.
This article systematically introduces the uses, types, measurement principles, selection criteria, and usage methods of viscosity cups.