Water Quality Automatic Analyzer

Water quality auto-analyzers continuously detect specific parameters in water through sensors, utilizing chemical or physical methods to convert water quality indicators into electrical signals for measurement. They are used for real-time monitoring of water pollution conditions and are commonly applied in scenarios such as wastewater treatment plant discharge outlets and river cross-sections for monitoring indicators like pH, turbidity, and dissolved oxygen.
Selection
Ensure that the monitoring parameters match the on-site requirements, check that the instrument's detection limit and measurement range cover the actual concentration levels of the water body. Consider the sample pretreatment needs and maintenance cycles, verify the compatibility of the data output interface with the existing system, and evaluate the operating consumable costs and the equipment's protection rating for suitability in the installation environment.

Terms

Standards

Instruments

Support 16 water quality paraMeters synchronous testing, equipped with IP67/IP68 waterproof rating and automatic temperature compensation system, data storage capacity up to 45000 groups, Measurement range covers 0-400mS/cm conductivity and 0-1000FNU turbidity.

$ 8494.00

12 water quality paraMeters can be measured simultaneously, with IP67 waterproof rating and 45,000 data storage capacity, support automatic temperature compensation and fast calibrating, with backlit graphic display and intuitive Operating interface.

$ 2949.00

Simultaneous measurement of 7 water quality paraMeters, turbidity Measurement range 0-50NTU, accuracy +/- 5%, in line with USEPA 180.1 standard, with chroma compensation and Illuminant automatic compensation function, reducing interference without frequent calibrating.

$ 2363.00

Can simultaneously measure 10 water quality indicators, including pH, ORP, conductivity, etc., with IP67 waterproof and automatic temperature compensation function, data storage capacity of 45,000, adapt to harsh environment measurement needs.

$ 3373.00

With 12 water quality paraMeter detection capabilities, resolution of 0.001mg/L, Repeatability 2%, micro-processing technology and long-life Illuminant, support custom Linear dispersion calibrating and data smoothing.

$ 1058.00

Can simultaneously measure 7 water quality indicators, IP67 waterproof design, 45000 data storage capacity, support 1 second to 3 hours custom storage interval, with automatic temperature compensation and GLP management function.

$ 2615.00

16 water quality paraMeters can be measured simultaneously, equipped with IP67/IP68 waterproof rating, support automatic temperature compensation and 44,000 Data storage, Measurement accuracy of +/- 0.02pH, intuitive and convenient operation.

$ 7264.00

It can simultaneously measure 10 water quality paraMeters, equipped with IP67 waterproof body and IP68 ElectRode, data storage capacity up to 45000 groups, support automatic temperature compensation and range identification, to ensure measurement accuracy in harsh environments.

$ 2904.00

With 5 measurement functions, support 1 to 5 point Conductivity Detector calibrating and automatic temperature compensation, can customize 13 paraMeters, equipped with 500 data storage and USB Communication interface, suitable for a variety of water quality paraMeters accurate measurement.

$ 667.00

Equipped with 18.25MΩ · cm ultra-pure water quality and 100L/H water pRoduction capacity, 7-inch color touchscreen displays three-way water quality and temperature in real time, supports consumables failure reminder and automatic circulation system to ensure stable water quality.

$ 5195.00

It can simultaneously measure 7 water quality indicators, IP67 waterproof level, 45000 data storage capacity, automatic temperature compensation and fast Adjustment, adapt to the harsh environment such as pipeline deep wells.

$ 2345.00

It can simultaneously measure 7 water quality paraMeters, equipped with 45,000 data storage capacity, adopts IP67 waterproof grade and intelligent ElectRode identification system, supports automatic temperature compensation and fast Adjustment.

$ 2074.00

With 40L/H water pRoduction capacity and 18MΩ · cm resistivity ultrapure water output, the 7-inch touchscreen displays three-way water quality and temperature in real time, supports automatic circulation, consumables reminder and disinfection functions, ensuring stable water quality and low bacterial contamination.

$ 4408.00

The double water outlet design can provide both UP and RO water simultaneously, with a water pRoduction capacity of 20L/H, a fully enclosed pipeline to maintain stable water quality, automatic timing flushing and water shortage protection functions, and quiet operation with noise below 40 decibels.

$ 829.00

Measurement range 0~ 500 ppm, accuracy +/- 3 ppm, support for CAL CheckTM Adjustment, suitable for a variety of water quality testing scenarios.

$ 215.00

Articles

Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Application of Automatic Film Coating Machine in Waterproof Coating Finishing of Textiles
Automatic film coating machines are used for waterproof coating finishing on textiles, enabling precise control of coating thickness, improving uniformity and production efficiency.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium Battery Separators
This article introduces the application of automatic coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional
Application of Automatic Film Coating Machines in the Preparation of Uniform Coatings in Laboratories
This article introduces the application of automatic film applicators in preparing uniform coatings in laboratories. Traditional manual coating methods are influenced by the operator's experience, making it difficult to ensure coating consistency.
Wavelength selection for the determination of sulfate content in water quality using photometric titrator
This article discusses how to select the wavelength when using a photometric titrator to determine the sulfate content in water. The core issue lies in the fact that wavelength selection directly affects the accuracy and anti-interference capability of the detection.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Automatic Potentiometric Titration for Rapid Detection of Chloride Ion Content in Cement
This article introduces a method for rapidly detecting the chloride ion content in cement using an automatic potentiometric titrator. Excessive chloride ions can corrode steel reinforcement and affect the lifespan of concrete, making accurate detection crucial.
Key operational points for determining the acid value of oils and fats using potentiometric titration.
This article introduces the key operational points for determining the acid value of oils and fats using potentiometric titration. The method principle involves dissolving the oil or fat sample, titrating it with a standard alkaline solution, automatically determining the endpoint based on the potential jump, and then calculating the acid value using the formula.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Key Points for Wet Film Thickness Control in the Preparation of Fluorocarbon Coatings for Photovoltaic Backsheets Using Automatic Film Coating Machines
This article introduces the key points of controlling wet film thickness in the preparation of fluorocarbon coatings for photovoltaic backsheets using an automatic coating machine. Wet film thickness directly affects the performance and uniformity of the coating after curing, making its control crucial.
Alignment Accuracy Control Method for Four-Sided Preparator When Used with Automatic Coating Machine
This article explores the alignment accuracy control when using a four-sided preparator in conjunction with an automatic coating machine. Alignment accuracy directly affects the uniformity of the coating and the reliability of detection.
Effect of Platform Temperature on Surface Drying Time of Waterborne Polyurethane Coatings in Heated Automatic Film Applicators
This study investigates the influence of the platform temperature of a heated automatic film applicator on the surface drying time of waterborne polyurethane coatings. The experiments reveal that as the platform temperature increases, the surface drying time of the coating significantly decreases, showing a negative correlation between the two.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Programmable Automatic Film Coating Machine: Application Techniques of Multi-Speed Function in Gradient Coating Preparation
This article introduces how the multi-segment variable speed function of a programmable automatic film applicator can be used to prepare gradient coatings.