Plated Layer Coating Thickness Gauge

A coating thickness gauge uses magnetic induction, eddy current, or ultrasonic principles to perform non-destructive testing of the thickness of metal or non-metal coatings on substrate surfaces. It is used for quality control in processes such as electroplating, spraying, and anodizing to ensure coating uniformity and corrosion resistance.
Selection
When selecting, consider the substrate type (magnetic/non-magnetic), coating material, measurement range (e.g., 0-2000μm), and accuracy (±1-3%). Prioritize equipment with probe sizes that match the workpiece being measured. For environments containing corrosive substances, choose models with a protection rating of IP54 or higher.

Terms

Standards

Instruments

Using magnetic Induction and eddy Current dual principle, it can simultaneously measure paints and zinc layer thickness. Measurement range is 0-1500 μm, accuracy is +/- 1%, suitable for composite coating system inspection.

$ 1387.00

Using magnetic Induction and eddy Current principle simultaneous measurement composite coatings, Measurement range 0~ 1500μm, error +/- 1%, can display a single coating and zinc layer thickness, suitable for the accurate detection of ferrous and non-ferrous substrates.

$ 1622.00

Using high-speed ADC data collection, resolution up to 1μm, can simultaneously measure the thickness of multi-layer coatings or coatings plus substrates, with gain automatic switching and estimated thickness setting function, Measurement range 13~ 1000μm (epoxy resin coating).

$ 1132.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Wire-wound design wet film thickness 9.1 μ m, steel wire diaMeter Φ 0.10mm, chrome-plated surface is easy to clean and prolong life, suitable for a variety of substrates, Spreader uniform and flexible.

$ 525.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

Measurement range 0-12mm, Accuracy of 1-3%, Support automatic identification of matrix material and continuous Measurement mode, suitable for pipeline anticorrosive layer defect location.

$ 696.00

Measurement range 25~ 3000μm, step tooth design Division 25μm to 200μm, can be quickly placed vertically on the coating surface to measure the thickness immediately.

$ 93.00

Using electromagnetic induction principle to achieve nondestructive detection, measurement range of 0-9500μm, accuracy +/- 3%. With continuous single double measurement mode, automatic identification of substrate material, support 2000 sets of data storage and four statistical functions.

$ 344.00

Impact energy 3N, Impact device mass 75g, suitable for measurement of small or thin specimens and surface hardening layer, the minimum thickness can be measured 1mm and the minimum hardening layer depth 0.2mm.

$ 764.00

Using magnetic Induction principle to achieve 0-6000μm large-range measurement, the error is only +/- 3%. With continuous single double measurement mode, support four-point statistical function, large-capacity storage of 2000 sets of data, automatic identification of matrix material.

$ 323.00

Ultrasonic nondestructive measurement technology, support up to 3 layers of coating system analysis, Measurement range 50~ 7600 μ m, with weatherproof shell and a variety of data connection methods, to meet the needs of industrial field complex environment.

$ 3987.00

Frequency 5.0MHz, support paint layer detection and emission to echo mode, Measurement range 2~ 160mm, suitable for a variety of workpiece thickness measurement.

$ 525.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.