Manual Range Voice MultiMeter

A manual range voice multimeter detects parameters such as voltage, current, and resistance by manually switching measurement ranges. It features a built-in voice module that broadcasts readings in real time. Designed for on-site electrical inspections or use by individuals with visual impairments, it provides auditory feedback during power maintenance and troubleshooting tasks.
Selection
When selecting, consider measurement accuracy and basic safety ratings, confirm voice clarity and volume adjustment functions. Check battery life and protective design, match the gear range based on common measurement scenarios, and ensure ease of operation and durability.
Display
Range Mode
Form Factor
Special Function

Terms

Instruments

Measurement principle using resistance method, Measurement range 2~ 70%, resolution 0.5%, Response Time only 1 second, with voice reminder, automatic shutdown and Data storage function, Operating temperature 0~ 40 ℃.

$ 93.00

Measurement principle using resistance method, accuracy of 0.1%, support a variety of grain Measurement range, with voice reminder and automatic shutdown function, portable design weighs only 254g.

$ 90.00

Measurement principle using resistance method, Response Time only 1 second, Measurement accuracy +/- (1% RH + 0.5), support 4 wood measurement types, with automatic shutdown and low power prompt function.

$ 89.00

Visual aiming and manual measurement, measurement range up to +/- 180 °, equipped with LED Illuminant to extend the service life, support 100mm/200mm ordinary testtube.

$ 444.00

With manual and automatic temperature compensation function, Measurement range 2.00~ 4.40pHCO3, resolution 0.01pHCO3, support temperature compensation range 5.0~ 50.0 ℃, the instrument is light and beautiful.

$ 382.00

The application width is more than 280mm, the thickness range of Spreader is 2um-1.1mm, and the manual drag is used to control the speed of Spreader to ensure the uniformity and accuracy of Spreader.

$ 6528.00

Adopting manual sprocket drive structure, Working Travel ≥ 80mm, equipped with four weight combinations, accurate drawing is achieved through replaceable 808 stylus, and different diaMeter graphics are supported.

$ 325.00

Measurement range 0.00μS/cm~ 100mS/cm, four-speed range switching, error +/- 0.7% F.S, with backlit LCD display and manual temperature compensation, Stability is high.

$ 215.00

5 Meters long cable design, Measurement accuracy is 0.01pH, temperature compensation mode can be selected manual or automatic, automatic temperature compensation type is equipped with 4 Probes, suitable for 0~ 60 ℃ environment.

$ 101.00

With 1 to 3 point calibrating and automatic range conversion function, Measurement range 0.01~ 20mS/cm, accuracy +/- 1.5% F.S., support manual temperature compensation and custom paraMeter settings, easy to operate.

$ 222.00

With manual and automatic temperature compensation function, Measurement range 0-6 pF, resolution up to 0.01 pF, support fluorine Ion concentration value display, easy operation and digital display intuitive and accurate.

$ 262.00

With manual and automatic temperature compensation function, potassium Ion concentration Measurement range 0~ 39 g/L, resolution of 0.01 pK, easy to operate, digital display intuitive, light weight only 1.5kg.

$ 382.00

The 2900ma large-capacity lithium battery can work for 20 hours, equipped with 2.4-inch high definition color screen and 16-bit data collection chip, supports one-button switching between PPM and mg/m3 units, and has triple alarm function of sound, light and vibration.

$ 687.00

Measurement range 0~ 180 °, accuracy +/- 0.1 °, manual injection system to avoid bubble problems, support a variety of Measuring methods and automatic data storage, suitable for surface tension analysis.

$ 2558.00

With manual and automatic temperature compensation functions, PCa Measurement range 0.00-6, resolution up to 0.01 pCa, lightweight and portable only 1.5kg, while displaying pF value and calcium Ion concentration value.

$ 382.00

Articles

Shore Durometer Selection: Matching Principles of Hardness Models and Measurement Ranges
This article introduces the selection method for Shore durometers, with the core focus on ensuring that the hardness type matches the material's hardness range and rebound characteristics. When selecting, the principle that the measured value falls within 20% to 80% of the full scale should be followed to avoid data distortion.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Selection of wet film thickness gauge range and accuracy requirements for comb teeth spacing.
When selecting a wet film thickness gauges, the key considerations are the measurement range and the accuracy of the comb teeth spacing. The range should cover the coating thickness with a slight margin to avoid being too small for measurement or too large, which could reduce resolution.
Selection Recommendations for Carton Compression Strength Testing Machines
When selecting a cardboard compression strength tester, the first step is to examine the core parameters, such as ensuring the force range covers the testing requirements with some margin, the accuracy is typically no less than ±1%, and the testing speed complies with standard specifications.
How to Choose a Suitable Multi-Parameter Water Quality Analyzer Based on Detection Indicators
When selecting a multi-parameter water quality analyzer, the first step is to clarify the parameters that need to be measured, such as physical, chemical, or biological indicators, because different parameters require different detection principles, measurement ranges, and accuracy levels for the instrument.
Don't be fooled by the specs! The 3 key metrics to focus on when purchasing a tensile testing machine.
When purchasing a tensile testing machine, don’t just look at the parameter sheet. Focus on three core indicators: first, the accuracy and range of the force measurement system; second, the accuracy of displacement and deformation measurements; and third, the performance of the control and data acquisition system.
An article tells you how to choose a fineness gauge.
This article introduces how to select and use a grind gauge. It is a tool for measuring particle size in coatings and inks. When selecting one, the first step is to choose the appropriate range based on the estimated fineness of the sample (commonly 0-50 µm or 0-100 µm).