Dual Planetary Mixer

The dual planetary mixer utilizes two mixing blades that rotate on their own axes while simultaneously revolving around the container, creating complex motion trajectories. This ensures thorough mixing of materials in three-dimensional space. It is used for the dispersion and kneading of high-viscosity materials such as adhesives and inks, effectively eliminating dead zones during mixing and ensuring uniformity.
Selection
When selecting, consider matching the material viscosity with the stirring power, determine the container volume based on the batch size, choose heating/vacuum functions according to process requirements, check the corrosion resistance of the paddle material, compare equipment sealing to prevent leakage, and ensure easy maintenance.

Terms

Standards

Instruments

Adopt biaxial planetary motion structure, revolution 0-70rpm and rotation 0-80rpm adjustable, equipped with automatic wall scraping device to achieve no dead point mixing, Total Power 6.75kw to meet a variety of material handling needs.

$ 7303.00

Adopting a planetary two-way swirl/spin structure, the mixing arm runs in reverse with the basket to achieve rapid mixing, with a maximum load of 300g and a speed range of 400-2800rpm. The equilibrate is quiet and can be operated directly in the syringe or test bottle.

$ 5237.00

Adopting a six-axis planetary stirring structure, including two sets of high-speed dispersers and low-speed twist paddles, with a revolution speed of 0-80rpm and a rotation speed of 0-3800rpm, it can achieve no dead-angle mixing, with a Vacuum Level of -0.098MPa, suitable for materials with a viscosity of up to 1 million mPa · s.

$ 14274.00

Using the principle of planetary motion, the grinding time is only 15-20 minutes, and the discharge particle size is up to 0.1 micron; it supports dry grinding, wet grinding, vacuum grinding and other methods, equipped with four-station design, Rotation speed 800rpm, suitable for various sample characteristics.

$ 1499.00

Adopting the principle of planetary motion, the grinding time only takes 15-20 minutes, the discharge particle size reaches 0.1 micron, supports dry grinding, wet grinding, vacuum grinding and other methods, and is equipped with a 200CFM heat dissipation system and a low center of gravity design to ensure stable operation.

$ 1573.00

Six-axis planetary stirring structure, equipped with high-speed disperser and low-speed twist paddle, Rotation speed 0-90rpm, dispersion Rotation speed 0-3800rpm, can achieve no dead angle mixing of materials, and has an online temperature measurement system, temperature error less than 1 ℃.

$ 82694.00

The planetary coaxial coaxial fretting focusing device is used for comfortable and stable focusing; the total magnification is 40X-1600X, and it is equipped with a liftable Abbe condenser and a double-decked mechanical stage to observe unstained specimens clearly.

$ 1977.00

Using the principle of planetary motion, the grinding time is only 15-20 minutes, the discharge particle size can reach 0.1 micron, support dry grinding, wet grinding and other grinding methods, simple operation and convenient maintenance.

$ 1499.00

Adopting the principle of planetary motion, the particle size of grinding discharge can reach 0.1 μm, supporting dry grinding, wet grinding, vacuum grinding and other methods, with four stations and 800rpm Rotation speed, safe and stable operation.

$ 1866.00

360 ° tumbling structure combined with planetary disk swirl/spin, maximum Processing capacity 12L, minimum discharge particle size 0.1μm, support a variety of grinding methods and materials, easy operation and power-off protection function.

$ 4213.00

360 ° tumbling structure combined with planetary disk swirl/spin, maximum Processing capacity 16L, support dry and wet grinding vacuum grinding, can reach 0.1 μm discharge particle size, with a variety of ball mill Tank material and grinding mode selection.

$ 5798.00

The 360 ° tumbling structure combined with the overall movement of the planetary disc and the ball mill can achieve stronger friction and impact energy; the maximum Processing capacity is 4000ml, and the minimum discharge particle size can reach 0.1μm. It supports dry grinding, wet grinding and other grinding methods to improve sample uniformity and efficiency.

$ 2453.00

360 ° tumbling structure combined with planetary disk swirl/spin, maximum Processing capacity 10L, minimum discharge particle size 0.1μm, support dry grinding wet grinding and other methods, can be equipped with a variety of materials ball mill Tank, easy to operate and with power protection function.

$ 4037.00

The 360-degree tumbling structure combined with planetary disk motion, the maximum Processing capacity of 60L, supports dry grinding, wet grinding and other grinding methods, can achieve the minimum discharge particle size of 0.1 μm, improve sample uniformity and efficiency.

$ 13015.00

360 degree tumbling structure combined with planetary disk swirl/spin, maximum Processing capacity 80L, minimum discharge particle size 0.1μm, support dry grinding, wet grinding, vacuum and other grinding methods, equipped with a variety of materials ball mill Tank to adapt to different samples.

$ 14482.00

Articles

Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Cupping test instrument detects the cracking resistance of coatings under deformation.
This article introduces how the cupping test instrument detects the cracking resistance of coatings under deformation. It uses a spherical punch to uniformly press against the back of the sample, causing the coating to bulge with the substrate, simulating biaxial stretching until the coating cracks. The indentation depth at this point is recorded as the key indicator.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Two-Step Method with Pre-Coating and Fine-Coating in Eliminating Bubble Defects for Dual-Blade Coater
The dual-blade coater employs a two-step method of pre-coating and precision coating to eliminate bubble defects during the coating process. In the pre-coating stage, high shear force is applied to break the bubbles in the slurry, causing them to rupture and rise to the surface. The precision coating stage then precisely controls the coating thickness, removing any remaining bubbles to form a uniform wet film.
Differences between single-beam and double-beam structures in paper stiffness testers
Paper stiffness testers come in both single-beam and double-beam structures. The choice should be based on testing standards, sample thickness, and precision requirements.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Cupping tester evaluates the ductility of coatings.
The cupping tester is a detection device used to evaluate the ductility of coatings under biaxial tension. During the test, the punch presses the sample into the die until the first continuous crack appears in the coating, at which point the penetration depth of the punch is recorded as the cupping depth.
How does a roll-to-roll coating machine achieve double-sided coating?
How does a roll-to-roll coating machine achieve double-sided coating? Double-sided coating is a process that simultaneously or sequentially applies functional coatings to both sides of a flexible substrate (such as film, paper, or metal foil).
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Pendulum Hardness Determination: Comparison of Applicability between Double Pendulum Method and Compound Pendulum Method
This article compares two pendulum methods for measuring coating hardness. The choice of method should consider material hardness and testing conditions, and both methods require standardized calibration and sample preparation.
When selecting a drop testing machine, whether to choose a single-arm or double-arm configuration depends on the size and weight of the packaging.
When selecting a drop tester, the choice between a single-arm or double-arm model mainly depends on the size and weight of the packaging. For small, lightweight, and regularly shaped items, a single-arm tester is sufficient. However, for larger, heavier, or irregularly shaped items, it is better to choose a double-arm tester, as it offers greater stability and ensures more accurate test results.