Horizontal Oven

The horizontal oven heats air through electric heating elements and uses horizontal airflow circulation to ensure uniform heating of samples, which is used for removing moisture from materials or curing coatings. It is commonly used in quality testing and production processes in industries such as coatings and plastics.
Selection
When selecting a horizontal oven, consider factors such as temperature range and uniformity, corrosion resistance of the inner chamber material, load-bearing capacity of sample racks, temperature control accuracy, and energy consumption indicators. Determine the required volume based on the actual sample size and process requirements, and select an appropriate power model based on the laboratory's power supply conditions.

Terms

Standards

Instruments

Adopt back heating and horizontal forced convection technology to ensure uniform temperature in the studio; Temperature control accuracy up to 0.1 ° C, Fluctuation +/- 0.5 ° C; Sensor fault alarm and over-temperature protection function, Timer Range 0-9999 minutes.

$ 580.00

Adopt back heating and horizontal forced convection design, Temperature Fluctuation +/- 0.5 ℃, Temperature range + 10 ℃~ 200 ℃, Sensor fault alarm and 9999 minutes timing function to ensure stable and efficient experiment.

$ 325.00

Adopt back heating structure and horizontal forced convection technology to ensure studio Temperature uniformity. Equipped with High Accuracy Platinum Resistance Sensor, Temperature Fluctuation is only +/- 0.5 ° C, supports 0-9999 minutes timing function, and has multiple Safety protection mechanisms.

$ 490.00

Adopt back heating horizontal forced convection technology, Temperature Fluctuation +/- 0.5 ℃, Temperature range RT + 10~ 200 ℃. Sensor fault alarm, over-temperature protection and independent temperature limit Control system ensure the safety and reliability of the experiment.

$ 377.00

Horizontal forced convection technology to ensure Temperature uniformity, temperature control accuracy of 0.1 ℃, equipped with High Accuracy Platinum Resistance Sensor and 9999 minutes timing function, suitable for a variety of non-flammable and explosive materials processing.

$ 422.00

Horizontal forced convection technology to ensure the studio Temperature uniformity, temperature control accuracy of 0.1 ℃ and Fluctuation +/- 1 ℃; Sensor fault alarm, over-temperature protection and 9999 minutes timing function, 304 stainless steel studio corrosion resistance easy to clean.

$ 367.00

Equipment supports vertical and horizontal combustion test, can set combustion and extinguishing time and repeability times, automatic stop test, Internal dimensions 305 * 355 * 610mm, suitable for a variety of organic materials.

$ 691.00

Low noise fan and single air duct design ensure Temperature Uniformity 2.50%, temperature control accuracy +/- 1.0 ℃, equipped with double-decked tempered Glass observation window for real-time monitoring of sample status.

$ 1042.00

Adopt horizontal oscillation mode, Frequency 0-240rpm continuously adjustable, stable work and low noise, equipped with 340 * 250mm tray to meet the needs of a variety of experimental containers.

$ 199.00

Horizontal Vibration Technology, Vibration Frequency 45-200Hz Adjustable, Throwing plate diaMeter 300mm, can handle multiple samples and automatically complete the polishing process.

$ 5834.00

Rated load 1000N, Travel 100mm, manual operation is stable, can adapt to a variety of Force Gauge, suitable for tension and compression load and plug force test, horizontal structure for desktop installation.

$ 256.00

Horizontal press measurement with physical positioning observation window, Repeatability accuracy up to dE * ab ≤ 0.02, support 5 measurement diaMeters and over 30 Measurement paraMeters, equipped with full band equalization LED Illuminant, Measurement time of about 1 second.

$ 1364.00

The PD array Detector is used to achieve 0.01 unit haze resolution, the open sample compartment supports vertical and horizontal dual-mode testing, and a dynamic measurement system is equipped to ensure data Reliability.

$ 1977.00

The PD array Detector is used to achieve 0.01 unit haze resolution, the open sample compartment supports vertical horizontal testing, and a dynamic measurement system is equipped to monitor environment changes to ensure data Reliability.

$ 1977.00

8L Tank Volume, Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05 ℃, equipped with maintenance-free pressure/suction pump, supports horizontal and vertical stirring to ensure uniform thermostatic.

$ 1332.00

Articles

Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Key Technical Points for Determining Paper Moisture Using the 105℃ Oven Method
This article introduces the specific procedure for measuring paper moisture using the 105°C oven method. The process involves placing paper samples into a 105°C oven and drying them until their weight remains constant, then calculating the moisture content based on the weight difference before and after drying.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.
Temperature gradient control in high-temperature ovens during thermal resistance testing.
The heat resistance test simulates the performance of materials under high temperatures using a high-temperature oven, and the accuracy of its results is highly dependent on the uniformity of temperature inside the oven. If the temperature gradient is poorly controlled, it can lead to uneven heating of samples from the same batch, compromising the validity of the test.
What are the differences between a vacuum oven and a conventional oven?
The main difference between a vacuum oven and a conventional oven lies in their working pressure. Conventional ovens operate at atmospheric pressure, heating through air convection, making them suitable for routine drying tasks. In contrast, vacuum ovens are evacuated to low pressure to reduce air presence, primarily relying on thermal radiation for heat transfer. This makes them ideal for processing heat-sensitive, oxidation-prone materials or those requiring thorough drying.
Natural Convection vs Forced Air Drying: What’s the Difference Between the Two "Schools" of Laboratory Ovens?
This article introduces two drying methods for laboratory ovens: natural convection and forced air drying. What are the differences between them?