High-temperature Infrared PyroMeter

High-temperature infrared thermometers measure temperature by receiving infrared radiation emitted from the surface of an object, converting it into an electrical signal, and displaying the temperature value. They are used for non-contact measurement of surface temperatures in high-temperature equipment such as furnaces and kilns, and for monitoring production conditions in metal smelting and glass manufacturing.
Selection
When selecting, consider that the temperature measurement range should cover the temperature of the object being measured, and pay attention to matching the target size with the distance coefficient. Adjust parameters based on the material's emissivity. For observing high-temperature areas, select a water-cooling jacket for protection. The response time should meet the speed of process changes. In environments with dust, prioritize fixed installation.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Standards

Instruments

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

Imported Infrared Sensor, CO2 concentration recovery time ≤ 3 minutes, temperature recovery ≤ 8 minutes, equipped with HEPA high-efficiency Filter, with door temperature heating system and automatic wind speed adjustment function.

$ 8955.00

Using shortwave infrared technology, temperature range 200~ 2200 ℃, accuracy +/- 2%, with laser positioning, data retention and emissivity adjustable functions, Response Time 500ms, object distance ratio 80:1.

$ 307.00

Imported Infrared Sensor, CO2 concentration control accuracy of +/- 0.1%, restore the set concentration within 3 minutes after opening the door; equipped with high temperature heating and humidity sterilizing system, can completely eliminate microbial pollution, circulating fan speed automatic adjustment to avoid sample volatilization.

$ 4122.00

Infrared Sensor to achieve CO2 concentration +/- 0.1% control accuracy, 3 minutes to quickly restore the set concentration; equipped with high temperature heating and humidity sterilizing function, effectively eliminate microbial contamination, circulating fan automatic speed control to protect the sample.

$ 4911.00

Using infrared Light spectrum measurement technology, the temperature measurement range covers -18 to 1150 ° C, the accuracy is +/- 2%, with 20:1 object distance ratio and 500ms fast Response, support Data storage and USB connection function.

$ 153.00

Using Infrared Sensor to control CO2 concentration, it can be restored to 5% set value within 3 minutes after opening the door for 30 seconds; equipped with 90 ℃ high temperature heating and humidity sterilizing system, fully sterilized for 18 hours; HEPA Filter makes the air mass in the box reach 100 clean level.

$ 5815.00

Using Infrared Sensor to achieve CO2 concentration +/- 0.1% control accuracy, equipped with high temperature heating and humidity sterilizing function, CO2 concentration is restored within 3 minutes after opening the door, and the circulating fan automatically adjusts the speed to avoid sample volatilization.

$ 5503.00

Using infrared CO2 Sensor, concentration recovery time ≤ 3 minutes, temperature recovery ≤ 8 minutes. Equipped with HEPA high-efficiency Filter, the air mass in the box can reach 100 clean levels, and the circulating fan speed is automatically controlled to avoid sample volatilization.

$ 5110.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, suitable for a variety of Sample Handling.

$ 1009.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor temperature control system, the studio is made of 304 stainless steel for fast and uniform heating.

$ 775.00

Infrared Sensor, CO2 recovery time ≤ 3 minutes, temperature recovery ≤ 8 minutes, equipped with HEPA high-efficiency Filter, the air mass in the box can reach 100 clean levels, and the circulating fan speed is automatically controlled to avoid sample volatilization.

$ 3728.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor temperature control system to achieve automatic thermostatic operation, the studio is made of 304 stainless steel, size 600 * 600 * 500mm.

$ 932.00

The temperature measurement range covers -18 to 1350 ° C, the object distance ratio is 20:1, and the Response Time is 500ms. It can safely and accurately measure the surface temperature of difficult-to-contact objects, and the structure is compact and easy to operate.

$ 171.00

Using vanadium oxidation uncooled infrared focal plane Detector, temperature resolution of 0.1 ℃, with 56 ° × 42.2 ° field of view and focus-free design, support center point temperature measurement and cold hot spot automatic tracking function.

$ 428.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.